Technical Reference Summary

Covered Models & Document Scope

L-BV7N series liquid-ring vacuum pumps/compressors, types 2BV7060, 2BV7061, 2BV7070 and 2BV7071. Variants -2 and -3 are listed for 2BV7060, 2BV7070 and 2BV7071; 2BV7061 is listed as -1. Document edition 07.2019, 610.00187.40.000.

Section-by-Section Technical Breakdown

pp. 10-11
Technical Data

Mechanical data, electrical data reference and operating conditions for the L-BV7N series. Includes weights, minimum heat-dissipation distances, noise levels, temperature limits, pressure limits, nominal operating-liquid flow rates and priming filling amounts.

  • Weights range from approx. 20 kg (2BV7060-2) to 68 kg (2BV7071-3).
  • Minimum distance from fan guard to adjacent surface: 34 mm for 2BV7060/2BV7061, 53 mm for 2BV7070/2BV7071.
  • Noise level measured per EN ISO 3744 at 1 m with medium throttling (100 mbar abs.) and connected lines, tolerance ±3 dB(A).
  • Electrical data is given on the drive motor rating plate.
  • Pumped gas/vapor and operating-liquid temperature max. +80 °C; operating-liquid min. +5 °C, nominal +15 °C; ambient +5 to +40 °C.
  • Max. discharge pressure during vacuum-pump operation 1.3 bar abs.; max. permissible pressure in pump-motor unit 8 bar abs.
  • Max. discharge pressure during compressor operation depends on type and frequency (e.g. 2BV7071: 3.5 bar abs. at 50 Hz, 2.2 bar abs. at 60 Hz).
  • Nominal operating-liquid flow rate and priming filling amount are tabulated per type and frequency.
pp. 12
Design and Operating Method

Describes the liquid-ring principle: an eccentrically arranged impeller in a cylindrical housing with operating liquid forming a rotating ring. Gas is drawn in through the inlet port, compressed and discharged through the discharge port.

  • Components: discharge connection (1), operating-liquid port (2), inlet connection (3), impeller (4), housing (5), discharge port (6), inlet port (7), operating liquid (8).
  • Impeller is arranged eccentrically relative to the housing.
  • Operating liquid is fed via the operating-liquid port and discharged together with the pumped gases/vapors via the discharge connection.
  • During rotation the liquid ring is concentric to the housing and eccentric to the impeller, creating increasing cell volume for suction and decreasing volume for compression.
pp. 13
Operating Modes

Defines self-priming operation and operation with operating-liquid feed (manual or automatic). The operating mode determines how and when the unit is filled with operating liquid and how it is commissioned.

  • Self-priming operation: the pump-motor unit automatically sucks in operating liquid; flow rate is automatically adjusted.
  • Operation with operating-liquid feed: the unit does NOT automatically suck in operating liquid; a nominal operating-liquid flow rate or pre-pressure must be set.
  • Manual operation uses a stop valve to switch operating-liquid feed on and off.
  • Automatic operation uses a solenoid valve that opens when the motor/pump-motor unit is switched on and closes when switched off.
pp. 16-21
Installation

Installation requirements for the pump-motor unit, including mounting position, surface, heat dissipation clearances, vibration limit and bolting. Also covers electrical connection of the motor and connection of pipes/hoses.

  • Install on level, stationary surfaces with shaft horizontal; maximum installation height 1000 m above sea level.
  • Comply with minimum distances for heat dissipation from Chapter 4.1.
  • Maximum permissible vibration velocity veff = 4.5 mm/s.
  • Bolt feet to supporting surface: 2BV706 with 4 x M8-6.8; 2BV707 with 4 x M10-6.8.
  • Electrical connection per national/local regulations and terminal-box circuit diagram; connect protective conductor.
  • Terminal plate tightening torques: M4 = 0.8–1.2 Nm; M5 = 1.8–2.5 Nm.
  • Clearance between bare live parts and to ground at least 5.5 mm at Vn ≤ 690 V.
  • Use motor circuit breakers set to the nominal current on the rating plate.
  • For converter supply use shielded cables with shield installed on both sides.
  • Pipe/hose connections: operating-liquid port G ¼", cavitation protection connection G ¼", drain opening G ¼".
  • Tightening torque for pipe connections on intake and discharge connections must not exceed 100 Nm.
  • Install a start-up screen in the inlet pipe for the first 100 operating hours.
pp. 22-25
Commissioning

Pre-start checks, filling with operating liquid, direction-of-rotation check and start-up procedures for self-priming operation and operation with operating-liquid feed.

  • Unit may only be started with fan guard and vacuum pump/compressor housing mounted, lines attached and tested for strength and leaks.
  • Do not run dry; mechanical seal is destroyed in seconds without operating liquid.
  • Maximum discharge pressure when gases/vapors are passed on is 1.1 bar abs.
  • For self-priming operation, fill with operating liquid during installation; for operation with operating-liquid feed, fill after completing installation.
  • For operation with operating-liquid feed, open the stop valve for approx. 20 seconds to fill the working area.
  • Check direction of rotation by briefly switching on and comparing external fan rotation with arrows on motor mounting adapter and fan guard.
  • Self-priming operation requires a vacuum of at least 900 mbar abs. in the inlet pipe at switch-on and liquid level at shaft center; during operation the reservoir level may not drop below approx. 1 m below shaft center.
  • For operation with operating-liquid feed, set pre-pressure pA approx. 1 bar above inlet pressure pB.
pp. 33
Repairs/Troubleshooting

Fault table listing symptoms, causes, remedies and the personnel responsible for each corrective action.

  • Covers motor not starting, protective motor switch tripping, high power consumption, and failure to generate vacuum.
  • Remedies include checking fuses/terminals/cables, freeing a jammed impeller, decalcifying, cleaning, correcting impeller gap, replacing impeller or motor bearings, throttling operating-liquid flow, reducing counter-pressure, sealing leaks and reversing direction of rotation.
  • Work is assigned to Electrician, Operator or Service as appropriate.

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Maximum temperature of pumped gases/vapors is +80 °C [+176 °F]. p.10 ↗ At higher fluid temperatures, measures must be taken on the system to prevent burns, e.g. mount a separating safety device (cover). whole series
Operating-liquid temperature: max. +80 °C, min. +5 °C, nominal +15 °C. p.10 ↗ Operating liquid must be kept within these limits; minimum inlet pressure depends on operating-liquid temperature (Fig. 1). whole series
Ambient temperature: max. +40 °C [+104 °F], min. +5 °C [+41 °F]. p.10 ↗ Installation location must remain within this ambient range. whole series
Max. discharge pressure during vacuum-pump operation: 1.3 bar abs. [18.8 psia]. p.10 ↗ System back-pressure on the discharge side must not exceed this value in vacuum operation. whole series
Max. permissible pressure in pump-motor unit: 8 bar abs. [116 psia]. p.10 ↗ If higher pressures can occur in the system, corresponding protective devices must be provided. whole series
Max. discharge pressure during compressor operation at inlet pressure p1 = 1 bar abs.: 2BV7060 2.0/2.4 bar abs. (50/60 Hz); 2BV7061 1.9/1.9 bar abs.; 2BV7070 3.0/2.5 bar abs.; 2BV7071 3.5/2.2 bar abs. p.10 ↗ Compressor duty limits are type- and frequency-dependent; select the type accordingly. 2BV7060, 2BV7061, 2BV7070, 2BV7071
Nominal operating-liquid flow rate with dry air extraction and water at 15 °C: 2BV7060 0.20 m³/h; 2BV7061 0.23 m³/h; 2BV7070 0.28/0.34 m³/h (50/60 Hz); 2BV7071 0.45/0.55 m³/h (50/60 Hz). p.11 ↗ Operating-liquid supply must be set to these nominal flow rates for proper operation. whole series
Operating-liquid filling amount for priming: 2BV7060 0.40 l; 2BV7061 0.55 l; 2BV7070 0.80 l; 2BV7071 1.10 l. p.11 ↗ Use these quantities when filling the working space before commissioning. whole series
Minimum distance from fan guard to adjacent surface: 34 mm for 2BV7060/2BV7061; 53 mm for 2BV7070/2BV7071. p.10 ↗ Maintain these clearances to ensure heat dissipation and cooling are not obstructed. 2BV7060, 2BV7061, 2BV7070, 2BV7071
Maximum permissible vibration velocity veff = 4.5 mm/s [0.177 in/s]. p.16 ↗ Installation and foundation must ensure total vibration does not exceed this value for proper operation and long service life. whole series
Feet bolting: 2BV706 uses 4 x M8-6.8; 2BV707 uses 4 x M10-6.8. p.17 ↗ Use suitable securing elements of these sizes to bolt the unit to the supporting surface. 2BV7060/2BV7061 (2BV706); 2BV7070/2BV7071 (2BV707)
Terminal plate tightening torques: M4 = 0.8–1.2 Nm; M5 = 1.8–2.5 Nm. p.18 ↗ Electrical connections must be tightened to these torques for a permanently safe connection. whole series
Clearance between bare live parts and between bare live parts and ground: at least 5.5 mm at nominal voltage Vn ≤ 690 V. p.18 ↗ Ensure no protruding wire pieces and maintain this clearance in the terminal box. whole series
Permissible supply deviations without reduction in performance: ±5 % voltage, ±2 % frequency. p.18 ↗ Operating conditions must correspond to the motor rating plate within these tolerances. whole series
Tightening torque for pipe connections on intake and discharge connections must not exceed 100 Nm [73.8 ft lbs]. p.20 ↗ Avoid over-tightening pipe connections to prevent damage. whole series
Self-priming operation requires a vacuum of at least 900 mbar abs. [13.1 psia] in the inlet pipe at switch-on, and the liquid level in the feed pipe/reservoir must be at the same level as the center of the unit shaft. p.24 ↗ Pre-throttle on the inlet side and establish correct liquid level before starting in self-priming mode. whole series
During self-priming operation the liquid level in the reservoir may not drop below approx. 1 m [3.28 ft] below the center of the unit shaft. p.24 ↗ Reservoir and feed pipe must be arranged to maintain this minimum level during operation. whole series
For operation with operating-liquid feed, set pre-pressure pA in the feed pipe approx. 1 bar [14.5 psi] above the inlet pressure pB. p.25 ↗ Operating-liquid feed pressure must be regulated relative to inlet pressure. whole series
Maximum discharge pressure when pumped gases/vapors are passed on is 1.1 bar abs. [16.0 psia]. p.22 ↗ Ensure downstream system cannot exceed this pressure during commissioning and operation. whole series
Installation height maximum 1000 m [3280 ft] above sea level. p.16 ↗ Higher altitudes require consultation with service. whole series

Faults & Troubleshooting

Code / Symptom Possible Cause Remedy Note
Motor does not start, no motor noise. p.33 ↗ At least two power supply leads interrupted. Check fuses, terminals and cables for open circuit. Eliminate open circuit. Carried out by: Electrician
Motor does not start, humming noise.. p.33 ↗ One power supply lead interrupted. Check fuses, terminals and cables for open circuit. Eliminate open circuit. Carried out by: Electrician
Motor does not start, humming noise.. p.33 ↗ Impeller is jammed. Free shaft by turning. See Chapter 11.1, "Maintenance", Pg. 30. Carried out by: Operator
Motor does not start, humming noise.. p.33 ↗ Impeller is jammed. Decalcify vacuum pump/compressor. See Chapter 11.1, "Maintenance", Pg. 30. Carried out by: Operator
Motor does not start, humming noise.. p.33 ↗ Impeller is jammed. Drain and clean vacuum pump/compressor if necessary. See Chapter 11.1, "Maintenance", Pg. 30. Carried out by: Operator
Motor does not start, humming noise.. p.33 ↗ Impeller is jammed. Check and correct impeller gap setting if necessary. Carried out by: Service
Motor does not start, humming noise.. p.33 ↗ Impeller defective. Replace impeller. Carried out by: Service
Motor does not start, humming noise.. p.33 ↗ Motor bearings defective. Replace motor bearings. Carried out by: Service
Protective motor switch trips when motor is switched on. p.33 ↗ Winding short-circuit. Have winding checked. Carried out by: Electrician
Protective motor switch trips when motor is switched on. p.33 ↗ Motor overloaded. Throttle operating-liquid flow rate. See Chapter 8.2, "Self-priming operation", Pg. 24 or 8.3, "Operation with operating-liquid feed", Pg. 25. Carried out by: Operator
Protective motor switch trips when motor is switched on. p.33 ↗ Counter-pressure at discharge connection too high. Reduce counter-pressure. Carried out by: Operator
Protective motor switch trips when motor is switched on. p.33 ↗ Share of liquid also fed too high. Reduce share of liquid also fed. Carried out by: Operator
Protective motor switch trips when motor is switched on. p.33 ↗ Impeller is jammed. See "Motor does not start, humming noise." Carried out by: Service
Power consumption too high. p.33 ↗ Lime or other deposits. Decalcify vacuum pump/compressor. See Chapter 11.1, "Maintenance", Pg. 30. Carried out by: Operator
Power consumption too high. p.33 ↗ Lime or other deposits. Clean vacuum pump/compressor. See Chapter 11.1, "Maintenance", Pg. 30. Carried out by: Operator
Unit does not generate vacuum. p.33 ↗ No operating liquid. Ensure proper operating-liquid flow rate. See Chapter 8.2, "Self-priming operation", Pg. 24 or Chapter 8.3, "Operation with operating-liquid feed", Pg. 25. Carried out by: Operator
Unit does not generate vacuum. p.33 ↗ Severe leak in the system. Seal leak in the system. Carried out by: Operator
Unit does not generate vacuum. p.33 ↗ Wrong direction of rotation. Reverse direction of rotation by interchanging two connecting leads. Carried out by: Electrician