Induztr
Engineering Digest Document Viewer Related Models

Unichiller 060Tw Technical Data

Contents

  1. Overview p. 1
    Introduces the Unichiller 060Tw model and its main features
  2. Spec pp. 1-2
    Lists performance, temperature, and dimensional specifications per DIN 12876
  3. p. 2 table, 14 rows
  4. p. 1 table, 34 rows

Technical data according to DIN 12876

ParameterValue
max. cooling water pressure6 bar
min. filling capacity5,9 l
Volume of expansion7,5 l
Overall dimensions WxDxH **600x600x1450 mm
Net weight201 kg
sound pressure level +/- 4 dB(A)57 dB(A)
Power supply (3 Phase)400V 3~ 50Hz
max. current (3 Phase)10 A
Fuse (3 phase)3x16A
Pressure equipment categoryArt. 4.3 PED
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C
from Serial-No.:S456818

** Please respect space requirements. See operating conditions at www.huber-online.com

Technical data according to DIN 12876 — Unichiller 060Tw (Order-No.: 3026.0106.01)

ParameterValue
Operating temperature range-20...40 °C
temperature set point / display5,7" colour Touchscreen
Internal temperature sensorPt100
Sensor external connectionPt100
Temperature stability at -10°C0,5 K
Interface digitalEthernet, USB (Host u. Device), RS232
Safety classificationI / NFL
Cooling power at 15°C6 kW
Cooling power at 0°C5 kW
Cooling power at -10°C3,1 kW
Cooling power at -20°C1,7 kW
Refrigeration machinewater-cooled, CFC- and HCFC-free
Refrigerant (ASHRAE, GHS)R-449A (A1, H280)
Global Warming Potential (GWP)1397
Refrigerant quantity1,15 kg
CO2 equivalent1,6 t
Circulation pumpC3
max. delivery80 l/min
max. delivery pressure5,6 bar
Delivery at 0,35 bar79 l/min
Delivery at 0,5 bar76 l/min
Delivery at 1,0 bar71 l/min
Delivery at 1,5 bar66 l/min
Delivery at 2,0 bar61 l/min
Delivery at 3,0 bar49 l/min
Delivery at 4,0 bar35 l/min
Delivery at 5,0 bar16 l/min
Pump connectionG1 1/4 male
Cooling water connectionG1/2 male
Consumption at water 15°C, flow 15°C330 l/h
Consumption at water 15°C, flow 0°C230 l/h
Consumption at water 15°C, flow -10°C152 l/h
Consumption at water 15°C, flow -20°C70 l/h
min. cooling water differential pressure1 bar

Engineering Facts

12 facts · every claim linked to a page
Installation

The chiller is water-cooled and requires a minimum cooling water differential pressure of 1 bar to operate.

Ensures the site's cooling water supply can provide adequate flow and pressure before installation.

Source
“min. cooling water differential pressure 1 bar”
Installation

The unit must be supplied with cooling water between 5°C and 20°C, and pipes must be insulated if water temperature can fall below the condensation point.

Prevents condensation and corrosion damage; defines the acceptable cooling water supply conditions.

Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C. When cooling water temperatures fall below the condensation point, it is essential to insulate the cooling water pipes in the unit.”
Performance

Cooling power ratings are valid only at 20°C room temperature, 15°C cooling water inlet, and 1 bar differential pressure.

Allows correct sizing; actual cooling capacity will differ if site conditions deviate from these reference values.

Source
“Output data valid for: Room temperature 20°C, cooling water inlet 15°C and 1 bar differential pressure between cooling water inlet and -”
Performance

Higher cooling water temperature reduces cooling power and may require increased cooling water flow rate.

Engineers must account for derating and higher water consumption when the available cooling water is warmer than 15°C.

Source
“As the cooling water temperature increases, drop in the cooling power should be expected, and also an increased cooling water flow rate possible.”
Installation

The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible cooling water may be used.

Prevents corrosion and fouling; guides water quality and material compatibility checks.

Source
“Materiels used in the cooling water circuit include; copper, Stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM. Please use suitable cooling water.”
Installation

Three-phase devices with current consumption below 63 A are delivered with a cable but without a plug.

The installer must provide and fit a suitable plug or hard-wire the connection on site.

Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Compliance

Voltage and frequency tolerances are ±5% and ±2% respectively, but opposite-sign deviations (e.g., -5% voltage with +2% frequency) are not allowed.

Defines the acceptable power supply quality; out-of-tolerance supply can damage the compressor and electronics.

Source
“-5% voltage and +2% frequency -> not allowed!”
Safety

The refrigerant R-449A is classified A1 with GHS hazard H280, and the unit contains 1.15 kg (1.6 t CO2 equivalent).

Informs refrigerant handling, leak detection, and F-gas reporting obligations.

Source
“R-449A (A1, H280)”
Installation

The unit has protection degree IP20 and must be installed in an environment between 5°C and 40°C ambient temperature.

IP20 offers no water protection, and ambient limits define the allowable installation location.

Source
“min. ambient temperature 5 °C max. ambient temperature 40 °C”
Installation

The unit requires a 400 V 3~ 50 Hz supply with a 3x16 A fuse and maximum current of 10 A.

Determines the electrical supply, protection device rating, and cabling required at the installation site.

Source
“Power supply (3 Phase) 400V 3~ 50Hz”
Operation

The expansion tank is atmospheric open and the unit is intended for externally closed applications.

Prevents pressurizing the expansion tank and guides correct connection of the external circuit.

Source
“Housing, atmospheric open expansion tank and copper soldered evaporator made of stainless steel.”
Maintenance

The digital level indicator helps monitor the fill level; minimum filling capacity is 5.9 l and expansion volume is 7.5 l.

Supports correct filling and periodic level checks to avoid pump cavitation or overflow.

Source
“With digital level indicator.”