Performance, temperature, and dimensional data per DIN 12876
p. 2table, 6 rows
p. 1table, 33 rows
Technical data according to DIN 12876
Parameter
Value
Power supply (3 Phase)
400V 3~ 50Hz
Pressure equipment category
I
Degree of Protection
IP20
min. ambient temperature
5 °C
max. ambient temperature
40 °C
from Serial-No.:
1.0/20
Technical data according to DIN 12876 — Unichiller 110T-H (Order-No.: 3027.0079.01)
Parameter
Value
Operating temperature range
-10...100 °C
temperature set point / display
5,7" colour Touchscreen
Internal temperature sensor
Pt100
Sensor external connection
Pt100
Interface digital
Ethernet, USB (Host u. Device), RS232
Temperature stability at -10°C
0,2 K
Safety classification
III / FL
Heating power
2 kW
Cooling power at 15°C
11 kW
Cooling power at 0°C
6 kW
Cooling power at -10°C
2,7 kW
Refrigeration machine
air-cooled, CFC- and HCFC-free
Refrigerant (ASHRAE, GHS)
R-449A (A1, H280)
Global Warming Potential (GWP)
1397
Circulation pump:
C3
max. delivery
96 l/min
max. delivery pressure
5,6 bar
Delivery at 0,5 bar
91 l/min
Delivery at 1,0 bar
86 l/min
Delivery at 1,5 bar
81 l/min
Delivery at 2,0 bar
75 l/min
Delivery at 2,5 bar
69 l/min
Delivery at 3,0 bar
63 l/min
Delivery at 3,5 bar
56 l/min
Delivery at 4,0 bar
48 l/min
Delivery at 4,5 bar
40 l/min
Delivery at 5,0 bar
29 l/min
Pump connection
G1 1/4 male
min. filling capacity
8,36 l
Volume of expansion
7 l
Overall dimensions WxDxH **
600x790x1614 mm
Net weight
232 kg
sound pressure level +/- 4 dB(A)
74 dB(A)
** Overall dimensions WxDxH
Engineering Facts
14 facts · every claim linked to a page
Selection
The chiller is rated for an operating temperature range of -10 to 100 °C, so it must be matched to the process temperature window.
Defines whether the unit can cover the required process temperatures before selection.
Source
“Operating temperature range -10...100 °C”
Performance
Cooling capacity drops sharply with lower temperature (11 kW at 15 °C, 6 kW at 0 °C, 2.7 kW at -10 °C), so sizing must use the capacity at the actual set point.
Prevents undersizing when the process runs cold rather than at ambient.
Source
“at 15°C 11 kW at 0°C 6 kW at -10°C 2,7 kW”
Installation
The unit requires a 3-phase 400 V 50 Hz supply, so site power must be verified before installation.
Determines electrical infrastructure and whether a suitable three-phase feed is available.
Source
“Power supply (3 Phase) 400V 3~ 50Hz”
Installation
Three-phase devices below 63 A are delivered with cable but without a plug, so the customer must provide the plug and connection.
Affects electrical installation scope and procurement of the mating plug.
Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Installation
Voltage and frequency tolerances are linked: ±5% voltage only with ±2% frequency, and opposite-sign deviations are not allowed.
Guides power quality assessment at the installation site to avoid invalid supply conditions.
Source
“-5% voltage and +2% frequency -> not allowed!”
Operation
Cooling capacity is specified at 20 °C room temperature and may fall if ambient temperature rises, so the room must be kept within limits.
Affects thermal design and ventilation of the installation room.
Source
“Output data valid for: Room temperature 20°C. If the ambient temperature rises, the cooling capacity may drop.”
Installation
The permitted ambient temperature range is 5 to 40 °C, so the installation location must stay within these limits.
Defines site conditions required for reliable operation and warranty compliance.
Source
“min. ambient temperature 5 °C max. ambient temperature 40 °C”
Installation
The unit is IP20, so it must be installed in a dry, protected location without water ingress risk.
Restricts placement in wet or dusty environments and informs enclosure planning.
Source
“Degree of Protection IP20”
Installation
The pump connection is G1 1/4 male, so hoses and fittings must match this thread.
Ensures correct hydraulic connection hardware is ordered.
Source
“Pump connection G1 1/4 male”
Performance
Pump delivery falls with rising pressure (96 l/min max, 29 l/min at 5.0 bar), so the system pressure drop must be checked against the pump curve.
Prevents insufficient flow in high-pressure-drop external circuits.