Introduces the Unistat 545w unit and its main features
Specpp. 1-2
Performance, temperature, and dimensional data per DIN 12876
p. 2table, 20 rows
p. 1table, 34 rows
Technical data according to DIN 12876
Parameter
Value
Pump connection
M38x1,5 male
max. permissible kin. viscosity
100 mm²/s
Cooling water connection
G3/4 male
Consumption at water 15°C, flow 0°C
1630 l/h
min. cooling water differential pressure
1 bar
max. cooling water differential pressure
4 bar
max. cooling water pressure
6 bar
max. System pressure
6 bar
min. filling capacity
9,9 l
Filling capacity expansion tank
19,9 l
Overall dimensions WxDxH **
730x804x1738 mm
Net weight
479 kg
Power supply requirement
400V 3~ 50Hz
max. current
58 A
Fuse
3x63A
Pressure equipment category
I
Degree of Protection
IP20
min. ambient temperature
5 °C
max. ambient temperature
40 °C
from Serial-No.:
S565746
** Please respect space requirements. See operating conditions at www.huber-online.com
Technical data according to DIN 12876
Characteristic
Unistat 545w
Order-No.
5012.0001.01
Operating temperature range
-55...250 °C
Temperature stability at -10°C
0,01 K
temperature set point / display
5,7" colour Touchscreen
Resolution of display
0,01 K
Internal temperature sensor
Pt100
Sensor external connection
Pt100
Interface digital
Ethernet, USB (Host u. Device), RS232
digital input
ECS ONE
digital output
POKO ONE
Interface analog
optional
Alarm message
optic, acoustic, relay
Safety classification
III / FL
Heating power
24 kW
Cooling power with Thermooil at 250°C
35 kW
Cooling power with Thermooil at 200°C
35 kW
Cooling power with Thermooil at 100°C
35 kW
Cooling power with Thermooil at 20°C
35 kW
Cooling power with Ethanol at 0°C
32 kW
Cooling power with Ethanol at -20°C
16 kW
Cooling power with Ethanol at -40°C
4 kW
Cooling power with Ethanol at -50°C
1,5 kW
Refrigeration machine
water-cooled, CFC- and HCFC-free
Refrigerant (ASHRAE, GHS)
R-452A (A1, H280)
Global Warming Potential (GWP)
2141
Refrigerant quantity
3,6 kg
CO2 equivalent
7,7 t
Circulation pump:
MK pump
max. delivery
196 l/min
max. delivery pressure
2,5 bar
Delivery at 0,5 bar
175 l/min
Delivery at 1,0 bar
152 l/min
Delivery at 1,5 bar
123 l/min
Delivery at 2,0 bar
86 l/min
Engineering Facts
14 facts · every claim linked to a page
Installation
The unit requires a 400 V 3-phase 50 Hz supply with a 3x63 A fuse, so the electrical installation must be sized for a 58 A maximum current.
Determines the site power supply, cable cross-section and upstream protection needed before installation.
Source
“Power supply requirement 400V 3~ 50Hz max. current 58 A Fuse 3x63A”
Installation
The cooling water circuit must be supplied at 1–4 bar differential pressure and no more than 6 bar static pressure, with 1630 l/h consumption at 15 °C.
Sizing of the cooling water supply, pump and piping must meet these pressure and flow limits.
Source
“min. cooling water differential pressure 1 bar max. cooling water differential pressure 4 bar max. cooling water pressure 6 bar”
Installation
Cooling water intake must stay between 5 °C and 20 °C, and pipes must be insulated if water temperature can fall below the dew point.
Out-of-range cooling water reduces cooling capacity and risks condensation, so the facility water supply must be checked.
Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C.”
Performance
Cooling capacity is rated at 35 kW with Thermooil from 20 °C to 250 °C but drops sharply with ethanol to 1.5 kW at -50 °C.
The heat transfer fluid choice and low-temperature process load must be matched to the actual available cooling power.
Source
“Cooling power with Ethanol at -50°C 1,5 kW”
Selection
The circulation pump delivers 196 l/min maximum but only 86 l/min at 2.0 bar, so external circuit pressure drop must be checked against the pump curve.
External loop resistance determines whether the required flow can actually be achieved.
Source
“max. delivery 196 l/min max. delivery pressure 2,5 bar Delivery at 2,0 bar 86 l/min”
Safety
The refrigerant R-452A is classified A1 with GHS hazard H280 and has a GWP of 2141 with 7.7 t CO2 equivalent, which affects refrigerant handling and reporting obligations.
Refrigerant charge, GWP and CO2 equivalent must be considered for leak detection, F-gas reporting and room ventilation.
Source
“R-452A (A1, H280) Global Warming Potential (GWP) 2141 Refrigerant quantity 3,6 kg CO2 equivalent 7,7 t”
Installation
The unit is IP20 and must be operated between 5 °C and 40 °C ambient, so it cannot be placed in a wet or dusty environment.
Site ambient conditions and enclosure protection dictate where the unit can be installed.
Source
“Degree of Protection IP20 min. ambient temperature 5 °C max. ambient temperature 40 °C”
Installation
The unit weighs 479 kg and measures 730x804x1738 mm, so floor loading and access route must be verified.
Transport, floor strength and doorway clearances must be planned before delivery.
Source
“Overall dimensions WxDxH ** 730x804x1738 mm Net weight 479 kg”
Installation
Three-phase devices below 63 A are supplied with cable but without a plug, so the customer must provide the final connection.
The electrical contractor must supply and install the appropriate plug or hard-wired connection.
Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Compliance
Voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%, and combinations such as -5% voltage with +2% frequency are not allowed.
Site power quality must be checked, since some voltage/frequency combinations invalidate the warranty and safe operation.
Source
“-5% voltage and +2% frequency -> not allowed!”
Safety
Leakage current exceeds 3.5 mA, which requires appropriate protective earthing and RCD selection.
Affects earth connection design and choice of residual current device in the electrical installation.
Source
“Attention: leakage current > 3,5mA”
Operation
The unit has an adjustable overtemperature protection according to DIN 12876 and safety classification III/FL.
The overtemperature cut-out must be set correctly for the application to protect the process and the operator.
Source
“With adjustable overtemperature protection according to DIN 12876.”
Maintenance
The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible cooling water may be used.
Water quality and treatment must be compatible with these materials to avoid corrosion and fouling.
Source
“Materiels used in the cooling water circuit include; copper, Stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.”
Selection
The unit is intended for both externally closed and externally open applications, which affects pump and expansion tank sizing.
Confirms suitability for open bath or external loop use, which influences installation layout and filling.
Source
“As well as for externally closed and also externally open applications.”