Product introduction and general description of the Unistat P520w unit
Specpp. 1-2
Technical performance data and operating parameters per DIN 12876
p. 2table, 22 rows
p. 1table, 30 rows
Technical data according to DIN 12876
Parameter
Value
Delivery at 1,5 bar
57 l/min
Delivery at 2,0 bar
46 l/min
Delivery at 2,5 bar
32 l/min
Pump connection
M30x1,5 male
max. permissible kin. viscosity
50 mm²/s
Cooling water connection
G1/2 male
Consumption at water 15°C, flow 20°C
492 l/h
min. cooling water differential pressure
1 bar
max. cooling water pressure
6 bar
min. filling capacity
4,9 l
Filling capacity expansion tank
16 l
Overall dimensions WxDxH **
540x604x1332 mm
Net weight
208 kg
sound pressure level +/- 4 dB(A)
61 dB(A)
Power supply requirement
400V 3~ 50Hz
max. current
14,5 A
Fuse
3x16A
Pressure equipment category
I
Degree of Protection
IP20
min. ambient temperature
5 °C
max. ambient temperature
40 °C
from Serial-No.:
S412416
** Please respect space requirements. See operating conditions at www.huber-online.com
Technical data according to DIN 12876
Characteristic
Unistat P520w
Order-No.
1072.0007.01
Operating temperature range
-55...250 °C
Temperature stability at -10°C
0,01 K
temperature set point / display
5,7" colour Touchscreen
Resolution of display
0,01 K
Internal temperature sensor
Pt100
Sensor external connection
Pt100
Interface digital
Ethernet, USB (Host u. Device), RS232
digital input
ECS ONE
digital output
POKO ONE
Alarm message
optic, acoustic, relay
Safety classification
III / FL
Heating power
6 kW
Cooling power with Thermooil at 250°C
6 kW
Cooling power with Thermooil at 200°C
6 kW
Cooling power with Thermooil at 100°C
6 kW
Cooling power with Thermooil at 20°C
6 kW
Cooling power with Ethanol at 0°C
6 kW
Cooling power with Ethanol at -20°C
4,2 kW
Cooling power with Ethanol at -40°C
1,5 kW
Cooling power with Ethanol at -50°C
0,65 kW
Refrigeration machine
water-cooled, CFC- and HCFC-free
Refrigerant (ASHRAE, GHS)
R-452A (A1, H280)
Global Warming Potential (GWP)
2141
Refrigerant quantity
1,44 kg
CO2 equivalent
3,1 t
Circulation pump: MK pump max. delivery
82 l/min
Circulation pump: MK pump max. delivery pressure
3 bar
Circulation pump: MK pump Delivery at 0,5 bar
75 l/min
Circulation pump: MK pump Delivery at 1,0 bar
66 l/min
Engineering Facts
14 facts · every claim linked to a page
Installation
The unit requires a 400 V three-phase supply with a 3x16 A fuse, so the electrical installation must be sized accordingly.
Determines the site power supply, cable and breaker rating needed before installation.
Source
“Power supply requirement 400V 3~ 50Hz max. current 14,5 A Fuse 3x16A”
Installation
The cooling water connection is G1/2 male and needs at least 1 bar differential pressure and no more than 6 bar, with about 492 l/h at 15 °C.
Sizes the cooling water supply, piping and pressure regulation for reliable heat rejection.
Source
“Cooling water connection G1/2 male Consumption at water 15°C, flow 20°C 492 l/h min. cooling water differential pressure 1 bar max. cooling water pressure 6 bar”
Installation
The unit is designed for cooling water intake between 5 °C and 20 °C, and pipes must be insulated if the water can fall below the condensation point.
Prevents condensation and ensures the specified cooling performance is available.
Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C. When cooling water temperatures fall below the condensation point, it is essential to insulate the cooling water pipes in the unit.”
Performance
Cooling capacity drops significantly at low temperatures with ethanol, from 6 kW at 0 °C to 0.65 kW at -50 °C, so low-temperature duty must be checked against the load.
Confirms whether the unit can hold the required low temperature under the actual process heat load.
Source
“Cooling power with Ethanol at 0°C 6 kW at -20°C 4,2 kW at -40°C 1,5 kW at -50°C 0,65 kW”
Performance
The circulation pump delivers 82 l/min at zero head but only 32 l/min at 2.5 bar, so system pressure drop must be matched to the pump curve.
Ensures adequate flow through high-pressure-drop external circuits such as flow-through chemistry.
Source
“max. delivery 82 l/min max. delivery pressure 3 bar Delivery at 0,5 bar 75 l/min Delivery at 1,0 bar 66 l/min”
Selection
The P models are specifically intended for applications with high pressure drops, such as flow-through chemistry or semiconductor industry.
Guides model selection when the external loop has high hydraulic resistance.
Source
“Unistat „P“ Models: Circulating pumps with a high discharge pressure for applications with high pressure drops, e.g. in the Flow-Through chemistry or in the Semicon industry.”
Safety
The refrigerant R-452A has a GWP of 2141 and a charge of 1.44 kg, giving 3.1 t CO2 equivalent that must be considered for environmental compliance and leak management.
Affects refrigerant handling, leak detection obligations and environmental permitting.
Source
“Refrigerant (ASHRAE, GHS) R-452A (A1, H280) Global Warming Potential (GWP) 2141 Refrigerant quantity 1,44 kg CO2 equivalent 3,1 t”
Safety
Leakage current exceeds 3.5 mA, so protective earthing and residual current protection must be designed for this.
Requires appropriate earth connection and RCD selection to avoid nuisance tripping or shock hazard.
Source
“Attention: leakage current > 3,5mA”
Installation
Voltage and frequency tolerances are ±5% and ±2% but must not combine in the same direction, e.g. -5% voltage with +2% frequency is not allowed.
Defines the acceptable site power quality for safe and reliable operation.
Source
“Voltage + / - 5% with a simultaneous frequency tolerance of + / - 2% Example -5% voltage and +2% frequency -> not allowed!”
Installation
Three-phase devices below 63 A are supplied with cable but without a plug, so the customer must provide the site plug and connection.
Clarifies what electrical termination work is required on site.
Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Operation
The unit is rated for ambient temperatures from 5 °C to 40 °C, so the installation room must stay within this range.
Prevents derating or faults caused by an unsuitable ambient environment.
Source
“min. ambient temperature 5 °C max. ambient temperature 40 °C”
Installation
The unit weighs 208 kg and measures 540x604x1332 mm, so floor loading and access routes must be planned.
Determines handling equipment, doorway clearance and floor load capacity.
Source
“Overall dimensions WxDxH ** 540x604x1332 mm Net weight 208 kg”
Compliance
The equipment is EMC class A group 1, which is intended for industrial environments and may cause interference in residential areas.
Affects installation location and EMC coordination with sensitive equipment nearby.
Source
“Classification (disturbance) to EN55011: Class A, Group 1”
Operation
The pump connections use bore shape Y (60°) per DIN 3863 with ball socket and sleeve nut per DIN 3870, so matching hoses and fittings must be ordered.
Ensures correct mating fittings and avoids leaks at the M30x1.5 pump connections.
Source
“Pump connections: Bore shape Y (60°) according to DIN 3863, pipework/flexible tempering hoses: Ball socket according to DIN 3863, sleeve nut according to DIN 3870.”