DuoVane 135 — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum DuoVane 135 and DuoVane 300, two-stage oil-lubricated rotary vane vacuum pumps. Both are three-phase motor versions; an M-version with magnetic coupling is offered as an option. Includes accessories/spare parts: seal, service, overhaul kits, spare pumping system, forevacuum safety valve kit, exhaust valve kit, coupling kit, vane kit, gas-ballast filter insert, oil mist separator, dust separator, temperature sensor, operations monitoring unit, mechanical oil filter, vacuum pump oil.
Section-by-Section Technical Breakdown
Introduces the DuoVane 135/300 two-stage oil-lubricated rotary vane pumps, highlighting integrated gas-ballast valve and vacuum safety valve for industrial use, ease of installation, compact design, and a wide accessory range.
- Two-stage oil-lubricated rotary vane principle
- Integrated gas-ballast valve and vacuum safety valve
- Compact design with wide range of accessories
- Option: M-version with magnetic coupling
Lists available kits, consumables and monitoring accessories for both pump models.
- Seal kit, service kit, overhaul kit, spare pumping system
- Forevacuum safety valve kit, exhaust valve kit, coupling kit, vane kit
- Filter insert for gas-ballast valve, oil mist separator, dust separator
- Temperature sensor, operations monitoring unit, mechanical oil filter
- M-version magnetic coupling option; vacuum pump oil
Provides nominal pumping speed (50/60 Hz, tolerance ±10%, air at 20°C), ultimate pressures with gas-ballast open/closed, motor data, noise, oil capacity, weight, dimensions and flange sizes for both models.
- Pumping speed: DuoVane 135 = 115/135 m³/h; DuoVane 300 = 250/300 m³/h (50/60 Hz)
- Ultimate pressure (ballast closed): 2·10⁻³ mbar (135), 3·10⁻³ mbar (300)
- Motor rating: 4/4.5 kW vs 7.5/9 kW; speed 1000/1200 min⁻¹
- Gas inlet/outlet: DN 63 ISO-F (135), DN 100 ISO-F (300)
- Weights 225 kg / 360 kg; oil capacity 14 l / 25 l
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| DuoVane 135 nominal pumping speed is 115 m³/h at 50 Hz and 135 m³/h at 60 Hz. p.2 ↗ | Select pump size based on actual line frequency; 60 Hz operation yields ~17% more speed. | DuoVane 135 |
| DuoVane 300 nominal pumping speed is 250 m³/h at 50 Hz and 300 m³/h at 60 Hz. p.2 ↗ | Plan pumping-time calculations per available mains frequency. | DuoVane 300 |
| Ultimate pressure with gas-ballast closed: 2·10⁻³ mbar (DuoVane 135), 3·10⁻³ mbar (DuoVane 300). p.2 ↗ | Use ballast closed for lowest base pressure applications. | both models |
| Ultimate pressure with gas-ballast open rises to 4·10⁻³ mbar for both models. p.2 ↗ | Account for degraded base pressure when condensate handling requires open ballast. | both models |
| Pumping speed curves apply to air at 20°C with tolerance ±10%. p.2 ↗ | Design margins for process gases or temperature deviations. | both models |
| Nominal motor rating: 4/4.5 kW (50/60 Hz) for DuoVane 135, 7.5/9 kW for DuoVane 300. p.2 ↗ | Size electrical supply and starter accordingly; three-phase only. | both models |
| Nominal motor speed is 1000/1200 min⁻¹ (50/60 Hz) for both models. p.2 ↗ | Low-speed design implies reduced vane wear; verify VFD use against fixed motor data. | both models |
| Both pumps use three-phase motors only. p.2 ↗ | No single-phase supply option; requires three-phase installation. | whole series |
| Noise level is 75 dB(A) at 50 Hz for both models. p.2 ↗ | Workplace noise assessment; 60 Hz operation likely slightly louder (not specified). | both models |
| Oil capacity is 14 l (DuoVane 135) and 25 l (DuoVane 300). p.2 ↗ | Plan oil inventory and change intervals; use specified Pfeiffer vacuum pump oil. | both models |
| Weight approx. 225 kg (135) and 360 kg (300); dimensions 1166x396x526 mm and 1407x460x670 mm (LxWxH). p.2 ↗ | Specify lifting equipment and mounting footprint accordingly. | both models |
| Gas inlet/outlet flanges: DN 63 ISO-F for DuoVane 135, DN 100 ISO-F for DuoVane 300. p.2 ↗ | Match pipework and ISO-F clamps/collars to flange size. | both models respectively |
| An M-version with magnetic coupling is available. p.1 ↗ | Choose for leak-tight shaft-free drive applications; affects coupling kit compatibility. | option for both models |
| Pumps include an integrated gas-ballast valve and vacuum safety valve. p.1 ↗ | Condensate/water vapor handling possible without external valve; forevacuum safety valve kit available as accessory. | whole series |
| Accessory kits include seal, service, overhaul, coupling, vane, exhaust valve and forevacuum safety valve kits, plus a complete spare pumping system. p.1 ↗ | Plan maintenance strategy using service/overhaul kits sized by operating hours. | both models |