Induztr
Engineering Digest Document Viewer Related Models

A 3004 H/X — product leaflet

Technical Reference Summary

Covered Models & Document Scope

Pfeiffer Vacuum A 3004 multi-stage Roots vacuum pump datasheet covering two variants: A 3004 H/X and A 3004 XN (2-page product leaflet, dated 01.07.2025).

Section-by-Section Technical Breakdown

pp. 1
Product Highlights

The leaflet opens with positioning claims for the A 3004 multi-stage Roots pump series: best-in-class compression ratio and lowest power consumption on the market. It emphasizes suitability for harsh processes with high particle tolerance and corrosion resistance, plus extended lifetime.

  • High performance: best-in-class compression ratio, lowest power consumption on the market
  • Robust: designed for very harsh processes, high particle tolerance, excellent corrosion resistance
  • Reliable: extended lifetime
pp. 2
Technical Data and Dimensional Drawing

Page 2 provides key performance data for both variants plus overall dimensions and connection sizes. Both A 3004 H/X and A 3004 XN share identical ultimate pressure, power draw, cooling, noise, weight, and flange sizes; they differ only in nominal pumping speed (3000 vs 2900 m³/h at 60 Hz).

  • Nominal pumping speed: 3000 m³/h (60 Hz) for A 3004 H/X; 2900 m³/h (60 Hz) for A 3004 XN
  • Ultimate pressure: 4 · 10⁻³ hPa (mbar) at 60 Hz (both variants)
  • Power consumption at ultimate pressure: 2.7 kW (60 Hz)
  • Cooling water flow: 2.5 – 5 l/min
  • Sound pressure level: < 72 dB(A)
  • Weight: approx. 800 kg
  • Dimensions (L × W × H): 961 × 544 × 1094 mm
  • Gas inlet / outlet: DN 160 / DN 40
  • Dimensional drawing and pumping speed curves shown in the leaflet

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Ultimate pressure is 4 · 10⁻³ hPa (mbar) at 60 Hz for both A 3004 H/X and A 3004 XN. p.2 ↗ Sets the base pressure floor for system design; a backing/fore pump is required to reach this range since a Roots pump cannot discharge to atmosphere. whole series (both variants)
Nominal pumping speed is 3000 m³/h (A 3004 H/X) vs 2900 m³/h (A 3004 XN) at 60 Hz. p.2 ↗ Variant choice depends on required throughput; the ~100 m³/h difference is the only performance distinction between the two models in this datasheet. A 3004 H/X vs A 3004 XN
Power consumption at ultimate pressure is 2.7 kW at 60 Hz. p.2 ↗ Size the motor supply circuit and estimate operating energy cost from this value, not motor nominal rating. whole series
Cooling water flow requirement is 2.5 – 5 l/min. p.2 ↗ Water cooling circuit with at least 2.5 l/min capacity must be plumbed; supports the water_vapor_tolerance/thermal management in harsh processes. whole series
Sound pressure level is below 72 dB(A). p.2 ↗ May allow installation without special acoustic enclosures in many industrial environments; still verify against site noise limits. whole series
Weight is approximately 800 kg. p.2 ↗ Requires appropriate lifting equipment, foundation/frame loading design (with dimensions 961 × 544 × 1094 mm), and rigging planning. whole series
Gas inlet is DN 160 and gas outlet is DN 40. p.2 ↗ Piping and connecting fore pump must match these flange sizes; large inlet DN 160 reflects the high-throughput Roots design. whole series
Overall envelope is 961 × 544 × 1094 mm (L × W × H). p.2 ↗ Verify clearance in the installation footprint, including access for cooling water and inlet/outlet connections. whole series
The pump is marketed with high particle tolerance and excellent corrosion resistance for very harsh processes. p.1 ↗ Suitable candidate for contaminated/corrosive vacuum processes, but specific chemical compatibility should be confirmed with Pfeiffer Vacuum for the actual process gas. whole series