UltiDry P1220 — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum UltiDry P1220, P1820 and P3020 multi-stage roots vacuum pumps (2-page datasheet dated 15.10.2026). Options/accessories: iN nickel coating, iN+ with double barrier 3D seals, high temperature and corrosion resistant seals, external check valve, silencer, EtherCAT communication, NFC communication, high or low voltage versions, cold/standard/hot versions.
Section-by-Section Technical Breakdown
The pumps are positioned as cost-efficient multi-stage roots pumps with low power consumption and a patented purge injection system that reduces N₂ and H₂O purge requirements. They claim the widest thermal range on the market (50°C to 270°C) and improved durability for harsh applications via enhanced powder management, corrosion resistance and thermal profile.
- Low power consumption with patented purge injection system to reduce N₂ and H₂O requirements
- Thermal range from 50°C up to 270°C
- Improved powder management, increased corrosion resistance, enhanced thermal profile for harsh applications
- Accessories/options: iN nickel coating, iN+ with double barrier 3D seals, HT/corrosion-resistant seals, external check valve, silencer, EtherCAT, NFC, high/low voltage, cold/standard/hot versions
A comparison table of the three models (P1220, P1820, P3020) covering pumping speed, ultimate pressure (with and without purge), power consumption, power supply, inlet flow limits, cooling, purge, noise, weight, dimensions, footprint and flange sizes. Pumping speed curves are given as air at 20°C with ±10% tolerance, and a dimensional drawing is included. Specifications may vary with configuration, accessories, installation and operating conditions.
- Max. pumping speed: 1200 / 1800 / 3000 m³/h (P1220 / P1820 / P3020)
- Ultimate pressure: 3.5·10⁻³ / 1.1·10⁻³ / 5.3·10⁻⁴ mbar (with 20 slm purge: 6·10⁻³ / 3.8·10⁻³ / 8.5·10⁻⁴ mbar)
- Power consumption at ultimate pressure: 2.65 / 2.65 / 2.55 kW
- Power supply: 210–230 V / 420–480 V three-phase ±10% (100 Hz)
- Max. inlet flow: 110 / 160 / 130 slm; max. continuous inlet flow: 80 / 120 / 110 slm
- Water cooling 2.5–5 l/min; N₂ purge flow 20–80 slm for all models
- Sound pressure level <66 dB(A) for all models
- Weight: 447 / 510 / 750 kg; dimensions 983×388×827 mm (P1220/P1820) and 1143×545×923 mm (P3020)
- Footprint: 0.35 m² (P1220/P1820), 0.59 m² (P3020)
- Inlet/exhaust flanges: DN 100 ISO-K / DN 40 ISO-KF (P1220); DN 160 ISO-K / DN 40 ISO-KF (P1820, P3020)
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Three models offered: P1220 (1200 m³/h), P1820 (1800 m³/h), P3020 (3000 m³/h) max pumping speed. p.1220 ↗ | Model selection by required pumping speed; pump curves given for air at 20°C with ±10% tolerance, so size with margin. | whole series |
| Ultimate pressure: P1220 3.5·10⁻³ mbar, P1820 1.1·10⁻³ mbar, P3020 5.3·10⁻⁴ mbar. p.2 ↗ | Only the P3020 reaches sub-10⁻³ mbar range; check backing pump performance for system ultimate pressure. | whole series (per model) |
| With 20 slm N₂ purge, ultimate pressure degrades to 6·10⁻³ / 3.8·10⁻³ / 8.5·10⁻⁴ mbar. p.2 ↗ | Purge use trades ultimate pressure for process protection; budget ~an order of magnitude for P1220. | whole series |
| Power consumption at ultimate pressure: 2.65 / 2.65 / 2.55 kW. p.2 ↗ | Energy budget for the pump is ~2.6 kW regardless of size; size supply and cooling accordingly. | whole series |
| Power supply is 210–230 V or 420–480 V three-phase ±10%, 100 Hz. p.2 ↗ | Verify site voltage and note high/low voltage variants must be ordered per installation; 100 Hz operation implies inverter-driven motor. | whole series |
| Max. inlet flow 110 / 160 / 130 slm and max. continuous inlet flow 80 / 120 / 110 slm. p.2 ↗ | Process gas throughput must stay below continuous limits; peaks above continuous but under max must be time-limited. | whole series (per model) |
| Water cooling requirement is 2.5–5 l/min for all models. p.2 ↗ | Specify a cooling water loop within this flow range; flow affects thermal profile selection (cold/standard/hot versions). | whole series |
| N₂ purge flow adjustable 20–80 slm. p.1 ↗ | Dimension purge gas supply for up to 80 slm per pump; patented injection reduces required purge versus conventional designs. | whole series |
| Sound pressure level below 66 dB(A) for all models. p.2 ↗ | Generally acceptable in lab/fab environments; optional silencer available for further reduction. | whole series |
| Weights: 447 kg (P1220), 510 kg (P1820), 750 kg (P3020). p.2 ↗ | Lifting equipment and structural support must be rated accordingly; P3020 needs substantial handling. | whole series (per model) |
| Footprints: 0.35 m² (P1220/P1820, 983×388×827 mm) and 0.59 m² (P3020, 1143×545×923 mm). p.2 ↗ | P1220 and P1820 share identical envelope, simplifying footprint planning and possible interchange. | P1220/P1820 share dimensions; P3020 larger |
| Flanges: P1220 inlet DN 100 ISO-K; P1820/P3020 inlet DN 160 ISO-K; all exhaust DN 40 ISO-KF. p.2 ↗ | Piping and accessories (check valve, valves) must match inlet size; exhaust DN 40 ISO-KF common across series. | whole series (per model) |
| Thermal operating range from 50°C to 270°C, claimed widest on the market. p.1 ↗ | Suitable for hot processes; select cold/standard/hot version variant to match process temperature. | whole series |
| iN nickel coating and iN+ with double barrier 3D seals options, plus high temperature and corrosion resistant seals. p.1 ↗ | For corrosive or particle-laden (harsh) applications, order coated/seal-protected variants to extend lifetime. | whole series (options) |
| EtherCAT and NFC communication options available. p.1 ↗ | EtherCAT enables integration into industrial control networks; NFC allows setup/diagnostics via mobile device. | whole series (options) |