COBRA DS 1200 A — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Busch COBRA DS dry screw vacuum pump series, datasheet (2 pages) covering three variants: COBRA DS 1200 A, COBRA DS 1800 A and COBRA DS 1800 A X (X version with tantalum-coated screw for harsh processes). Includes performance data, connections, utilities consumption and dimensions; brochure states suitability for solar, flat panel, semiconductor (etch, CVD) processes.
Section-by-Section Technical Breakdown
The COBRA DS 1200/1800 A/A X are dry screw vacuum pumps combining an integrated vacuum booster with a backing pump on a compact base frame. They target solar, flat panel and semiconductor applications and harsh high-gas-temperature processes such as etch and CVD, with good powder handling. The X variant features a tantalum-coated screw for harsh applications.
- Advanced screw design with integrated vacuum booster, directly mounted canned motor
- Suited for solar, flat panel and semiconductor applications; harsh processes with high gas temperatures (etch, CVD)
- Excellent powder handling; tantalum-coated screw on X variant
- Claimed benefits: low cost of ownership, long service intervals, high hydrogen throughput, low energy consumption, variable temperature control, low vibration
A data table compares the DS 1200 A, DS 1800 A and DS 1800 A X variants: pumping speed, ultimate pressure, motor ratings and speeds, sound level, cooling water and nitrogen consumption, weight, dimensions and flange connections. Pumping speed curves are for air at 20°C with ±10% tolerance.
- Nominal pumping speed: 1200 m³/h (DS 1200 A), 1700 m³/h (DS 1800 A and 1800 A X)
- Ultimate pressure: 0.003 hPa (mbar) for all variants
- Backing pump motor: 4.0/4.4 kW at 3000/3600 min⁻¹ (50/60 Hz) for DS 1200 A; 4.4 kW at 5100 min⁻¹ for DS 1800 A; 6.6 kW at 3600 min⁻¹ for DS 1800 A X
- Vacuum booster motor: 4.0 kW at 5400 min⁻¹ for all variants
- Sound pressure level (ISO 2151, KpA = 3 dB): < 62 dB(A) for all variants
- Cooling water: 7.0–8.0 l/min (min. 7.0–8.0 for the X); nitrogen: 0–75 l/min
- Weight: 500 kg (DS 1200 A / DS 1800 A), 520 kg (DS 1800 A X)
- Dimensions (L×W×H): 1073×426×740 mm (DS 1200 A), 1073×426×750 mm (DS 1800 A), 1124×426×750 mm (DS 1800 A X)
- Connections: gas inlet DN 160 ISO-K, outlet DN 40 ISO-KF on all variants
- Pumping speed measured with air at 20°C, tolerance ±10%
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Ultimate pressure is 0.003 hPa (mbar) for all three variants p.2 ↗ | Suitable for high-vacuum process applications; compare against process base-pressure requirement before selecting between variants | whole series |
| Nominal pumping speed: 1200 m³/h for DS 1200 A, 1700 m³/h for DS 1800 A and DS 1800 A X (air at 20°C, tolerance ±10%) p.2 ↗ | Size process throughput with ±10% uncertainty; a DS 1800 may deliver as little as ~1530 m³/h at nominal conditions | whole series |
| Backing pump motor ratings differ: 4.0/4.4 kW at 3000/3600 min⁻¹ (50/60 Hz) for DS 1200 A, 4.4 kW at 5100 min⁻¹ for DS 1800 A, 6.6 kW at 3600 min⁻¹ for DS 1800 A X p.2 ↗ | Electrical supply sizing must be per variant; DS 1800 A X requires roughly 50% more backing-pump power than the standard DS 1800 A | per model as listed |
| All variants include an integrated vacuum booster with a 4.0 kW motor running at 5400 min⁻¹ p.2 ↗ | Provide power and controls for two motors per pump package; booster speed is fixed regardless of line frequency | whole series |
| Required cooling water flow is 7.0–8.0 l/min (minimum 7.0–8.0 l/min for DS 1800 A X) p.2 ↗ | Water cooling circuit of at least ~8 l/min must be provisioned; loss of cooling likely limits operation | whole series |
| Nitrogen consumption is 0–75 l/min depending on operating mode p.2 ↗ | Purge-gas supply and mass-flow control up to 75 l/min N2 must be included in the process installation design | whole series |
| Sound pressure level is < 62 dB(A) per ISO 2151 with tolerance KpA = 3 dB p.2 ↗ | Typical installation may not need special acoustic measures; allow up to 65 dB(A) in worst-case acoustic planning | whole series |
| Gas inlet is DN 160 ISO-K and outlet DN 40 ISO-KF on all variants p.2 ↗ | Specify ISO-K 160 inlet hardware and ISO-KF 40 foreline piping; connections are identical so piping design is common across variants | whole series |
| Weight is approx. 500 kg (DS 1200 A and DS 1800 A) and 520 kg (DS 1800 A X) p.2 ↗ | Foundations, lifting gear and frames must be rated for ≥520 kg plus piping loads | whole series |
| Footprint dimensions: 1073×426×740 mm (DS 1200 A), 1073×426×750 mm (DS 1800 A), 1124×426×750 mm (DS 1800 A X) p.2 ↗ | Allow ~1.13 m length clearance for the X variant; width is uniform at 426 mm enabling interchangeable layouts | whole series |
| The DS 1800 A X uses a tantalum-coated screw p.1 ↗ | Select the X variant where corrosive/harsh chemistry (e.g., etch/CVD byproducts) would attack a standard screw; expect higher power draw (6.6 kW) and weight (520 kg) | COBRA DS 1800 A X only |
| Backing pump nominal motor speed is 3000/3600 min⁻¹ for the DS 1200 A (50/60 Hz) but 5100 min⁻¹ for the DS 1800 A regardless of frequency listing p.2 ↗ | Speed-dependent noise, wear and sizing of downstream components differ between the two; the DS 1800 A runs its backing pump substantially faster | DS 1200 A vs DS 1800 A |