COBRA BC 0601 G — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Busch COBRA BC 0601 G, BC 1001 G and BC 1200 A dry screw vacuum pumps — each an integrated package combining a screw backing pump with a mounted vacuum booster (canned motor) on a compact base frame. Data sheet covers performance, technical data and dimensional/consumable figures for the three models.
Section-by-Section Technical Breakdown
The COBRA BC series are dry screw vacuum pumps with a bell-shaped construction, patented self-balancing screws and an integrated vacuum booster. They are directly water-cooled with a directly mounted canned motor and combine backing pump plus booster on a compact base frame. Targeted at semiconductor and coating applications such as cold ALD, load lock/transfer chambers, metrology, lithography, PVD, RTA and oxide/silicon/metal etching.
- Advanced screw design with patented self-balancing screws and bell-shaped construction
- Integrated vacuum booster combined with backing pump on a compact base frame
- Direct water cooling and directly mounted canned motor
- Applications: cold atomic layer deposition, load lock and transfer chambers, metrology, lithography, PVD, rapid thermal annealing, oxide/silicon/metal etching
- Positioned for low cost of ownership, minimal maintenance, long service intervals and high uptime
Performance and connection data are given for air at 20°C with ±10% pumping speed tolerance, for 50 Hz and 60 Hz operation. All models reach an ultimate pressure of 0.003 hPa and use a 1.5 kW / 3000 min⁻¹ backing pump motor; booster motor rating and speed increase with model size. Noise level is 60 dB(A) per ISO 2151 for all models.
- Nominal pumping speed: BC 0601 G 550/640 m³/h, BC 1001 G 870 m³/h, BC 1200 A 1200 m³/h (50/60 Hz)
- Ultimate pressure 0.003 hPa (mbar) for all models at 50 and 60 Hz
- Backing pump motor 1.5 kW at 3000 min⁻¹ for all models; booster motors 1.5 / 2.9 / 4.0 kW (BC 0601/1001/1200)
- Booster speeds 3000/3600 min⁻¹ (BC 0601 G), 5400 min⁻¹ (BC 1001 G and BC 1200 A)
- Power consumption at ultimate/idle: 1.25/1.35 kW (0601 G), 1.7/1.2 kW (1001 G), 1.9/1.3 kW (1200 A)
- Cooling water minimum 3.0–4.0 l/min (0601 G, 1001 G), 4.0–5.0 l/min (1200 A)
- Nitrogen purge 0–70 l/min (0601 G, 1001 G), 0–200 l/min (1200 A)
- Weight approx. 320 kg (0601 G), 310 kg (1001 G), 360 kg (1200 A)
- Dimensions L×W×H: 905×354×660 mm (0601 G), 1054×425×615 mm (1001 G and 1200 A)
- Inlet/outlet: DN 63 ISO-K / DN 40 ISO-KF (0601 G), DN 100 ISO-K / DN 40 ISO-KF (1001 G), DN 160 ISO-K / DN 40 ISO-KF (1200 A)
- Sound pressure level 60 dB(A) (ISO 2151, KpA = 3 dB) for all models
Page 2 provides a dimensional drawing for footprint/installation planning and pumping speed curves plotted for 50 Hz (solid) and 60 Hz (dashed). Curves are measured with air at 20°C and carry a ±10% tolerance.
- Dimensional drawing included for all three models
- Pumping speed curves for 50 Hz and 60 Hz operation
- Curves valid for air at 20°C, tolerance ±10%
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Ultimate pressure is 0.003 hPa (mbar) for BC 0601 G, BC 1001 G and BC 1200 A at both 50 and 60 Hz. p.2 ↗ | Suitable for high-vacuum semiconductor processes (ALD, load lock, metrology) without a separate high-vacuum stage beyond the integrated booster. | whole series |
| Nominal pumping speeds: 550/640 m³/h (BC 0601 G, 50/60 Hz), 870 m³/h (BC 1001 G), 1200 m³/h (BC 1200 A). p.2 ↗ | Model selection by required throughput; 60 Hz gives ~16% more speed only on the BC 0601 G. | whole series |
| Pumping speed tolerance is ±10% for air at 20°C. p.2 ↗ | Size process plumbing and pump-down time calculations with this margin. | whole series |
| Backing pump motor is 1.5 kW at 3000 min⁻¹ on all models; booster motors are 1.5, 2.9 and 4.0 kW respectively. p.2 ↗ | Total connected electrical load ranges from ~3.0 kW (0601 G) to 5.5 kW (1200 A) for supply sizing. | BC 0601 G / BC 1001 G / BC 1200 A |
| Booster speed is 3000/3600 min⁻¹ (BC 0601 G) but 5400 min⁻¹ for BC 1001 G and BC 1200 A. p.2 ↗ | Higher-speed boosters on the larger models imply stricter dynamic balance/vibration service expectations. | BC 1001 G and BC 1200 A |
| Power consumption at ultimate/idle: 1.25/1.35 kW (0601 G), 1.7/1.2 kW (1001 G), 1.9/1.3 kW (1200 A). p.2 ↗ | Allows energy cost estimation at base vacuum and idle operation. | whole series |
| Minimum cooling water flow is 3.0–4.0 l/min for BC 0601 G/BC 1001 G and 4.0–5.0 l/min for BC 1200 A (direct water cooling). p.2 ↗ | Cooling water circuit must be sized before commissioning; no separate oil cooling loop is needed. | whole series |
| Nitrogen purge consumption ranges 0–70 l/min on BC 0601 G/BC 1001 G and 0–200 l/min on BC 1200 A. p.2 ↗ | For etching/ALD processes, N2 purge supply must cover up to 200 l/min on the largest model for dilution of corrosive/condensable species. | whole series |
| Inlet/outlet connections: DN 63 ISO-K / DN 40 ISO-KF (0601 G), DN 100 ISO-K / DN 40 ISO-KF (1001 G), DN 160 ISO-K / DN 40 ISO-KF (1200 A). p.2 ↗ | Exhaust lines can share DN 40 ISO-KF hardware across models; inlet flange must match the chosen model. | whole series |
| Weights are approx. 320 kg (0601 G), 310 kg (1001 G) and 360 kg (1200 A). p.2 ↗ | Lifting equipment and frame loading must be rated for ≥360 kg including rigging. | whole series |
| Envelope dimensions 905×354×660 mm (BC 0601 G) and 1054×425×615 mm (BC 1001 G / BC 1200 A). p.2 ↗ | Fit-in-place planning in semiconductor substories: the 0601 G has a notably narrower 354 mm width. | whole series |
| Sound pressure level is 60 dB(A) per ISO 2151 (KpA = 3 dB) for all models at 50/60 Hz. p.2 ↗ | Acceptable near process tools without acoustic enclosure in most fab environments. | whole series |
| The pumps use a directly mounted canned motor and direct water cooling, dry screw operating principle with integrated vacuum booster. p.1 ↗ | No lubricant in the pumping chamber — suitable for clean/corrosive semiconductor processes and oil-free applications. | whole series |