COMBI RH 1102 — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum COMBI RH series vacuum pump units (roots booster + dry backing pump combos), covering ~28 model variants spanning COMBI RH 902 to COMBI RH 5104 L, each pairing a HiLobe vacuum booster (HiLobe 1302/2104/2704/4504/6204) with COBRA NC/NX series backing pumps. 'L' variants pair HiLobe boosters with COBRA NX backing pumps; non-L variants use COBRA NC backing pumps.
Section-by-Section Technical Breakdown
Highlights reliability (integrated process monitoring sensors, intelligent booster UI), performance (high pumping speed at low ultimate pressures, fast pump-down, energy efficiency) and flexibility (configurable booster/backing-pump combinations and design options).
- High uptime and increased safety via process monitoring through integrated sensors
- Intelligent user interface on the vacuum booster
- High pumping speed at low ultimate pressures, fast pump-down times, high energy efficiency
- Various design options; different combinations of backing pumps and vacuum boosters possible
Lists available accessories and configuration options for the COMBI RH units, including control, protection, monitoring and mounting options.
- Control unit for booster and backing pump
- Protective strainer
- Splinter protection
- Temperature sensor
- Gas ballast and barrier gas
- Gear chamber evacuation
- Various feet: height-adjustable machine foot, castor wheels, floor mounting
Tabulated specifications for all COMBI RH variants: booster and backing pump pairing, pumping speed at 1 hPa, ultimate pressure, max power consumption, input voltage, noise level (ISO 2151), weight and gas inlet/outlet flange sizes. Pumping speeds range from 959 to 5098 m³/h, ultimate pressures from 1·10⁻³ to 1·10⁻² hPa.
- All models: 400 V AC (±10%), 50 Hz input; noise ≤80 dB(A) at 1 hPa (ISO 2151)
- Best ultimate pressure: 1·10⁻³ hPa (COMBI RH 1252, NC 0630 C pairing); COBRA NC-based units reach 2–7·10⁻³ hPa, COBRA NX 'L' units 1·10⁻² hPa
- Highest pumping speed: COMBI RH 5104 L at 5098 m³/h (HiLobe 6204 + COBRA NX 0950 A)
- Power consumption range: 6 kW (RH 902) to 26 kW (RH 5104 L)
- Weight range: ~550 kg (RH 902) to ~1450 kg (RH 2504/3804/5104 L)
- Inlet flanges: DN 100 ISO-F (smaller units) or DN 160 ISO-F/PN 16 (larger units); outlets DN 40–DN 80 PN 16, G 2"/G 3", or DN 100 ISO-K
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| All COMBI RH variants operate on 400 V AC ±10% at 50 Hz. p.2 ↗ | Single supply specification simplifies site electrical design across the whole series; verify local grid tolerance. | whole series |
| Noise level ≤80 dB(A) at 1 hPa for every model (ISO 2151). p.2 ↗ | No special acoustic enclosure typically needed even for the largest variants. | whole series |
| Best achievable ultimate pressure is 1·10⁻³ hPa with COMBI RH 1252 (HiLobe 1302 + COBRA NC 0630 C). p.4 ↗ | For lowest-pressure processes, select NC-based (non-L) combinations rather than NX 'L' variants. | COMBI RH 1252 |
| All COBRA NX 'L' variants (e.g. RH 2204 L, RH 2404 L, RH 4904 L) have ultimate pressure 1·10⁻² hPa. p.2 ↗ | NX-based units trade ultimate pressure for higher speed; avoid for processes needing <1·10⁻² hPa. | all COMBI RH L-variants with NX backing pumps |
| Highest pumping speed is 5098 m³/h at 1 hPa (COMBI RH 5104 L: HiLobe 6204 + COBRA NX 0950 A). p.3 ↗ | Upper performance ceiling for series selection; requires 26 kW and ~1450 kg support. | COMBI RH 5104 L |
| Largest units (RH 2504/3804/5104 L) weigh ~1450 kg; smallest (RH 902) ~550 kg. p.3 ↗ | Floor loading and lifting equipment must be sized to 1450 kg for the large NX 0950 A-based units. | COMBI RH 2504 L / 3804 L / 5104 L |
| Max power consumption spans 6 kW (RH 902) to 26 kW (RH 5104 L). p.2 ↗ | Electrical supply sizing: from ~9 A to ~38 A per phase at 400 V, accounting for motor starting current. | whole series |
| Gas inlet flanges are DN 100 ISO-F for smaller units and DN 160 ISO-F/PN 16 for larger units. p.2 ↗ | Pipework and mating flange hardware must be matched per model class before ordering. | whole series (per model) |
| Gas outlet options include DN 40/DN 50/DN 80 PN 16, G 2", G 3", and DN 100 ISO-K depending on model. p.2 ↗ | Exhaust line and fore-vacuum plumbing must match the specific variant's outlet standard. | per model |
| COMBI RH 1252 (NC-based) reaches 1·10⁻³ hPa while the same-speed RH 1252 L (NX-based) reaches only 7·10⁻³ hPa. p.4 ↗ | Same pump-speed class exists in two configurations; ultimate-pressure requirement dictates NC vs NX choice. | COMBI RH 1252 vs RH 1252 L |
| Optional gas ballast and barrier gas connections and gear chamber evacuation are available. p.1 ↗ | Enables handling of condensable vapors and protection of the booster gear oil against process contamination. | whole series |
| Optional temperature sensor and protective strainer / splinter protection are offered. p.1 ↗ | Recommended for process monitoring and inlet particle protection to safeguard the booster. | whole series |
| Mounting options include height-adjustable machine feet, castor wheels, and floor mounting. p.1 ↗ | Installation layout can be adapted for fixed or mobile deployment; floor anchoring available. | whole series |
| Pumping speed ratings are specified at 1 hPa (mbar), not at ultimate pressure. p.2 ↗ | Size the pump by speed at your actual operating pressure; speed at 1 hPa does not extrapolate directly to lower pressures. | whole series |
| COMBI RH 4254 L uses HiLobe 6204 with the smaller COBRA NX 0450 A backing pump, giving 4239 m³/h at only 15 kW and 940 kg. p.3 ↗ | An efficient mid/high-speed option where power and floor load are constrained but flow is not. | COMBI RH 4254 L |