Induztr
Engineering Digest Document Viewer Related Models

HiLobe 2704 — product leaflet

Technical Reference Summary

Covered Models & Document Scope

Pfeiffer Vacuum HiLobe vacuum booster series, covering three models: HiLobe 2704, HiLobe 4504 and HiLobe 6204. Options/accessories: Profinet converter, barrier gas kit (plastic/stainless), gear chamber evacuation, flushing device (spray lance), temperature/pressure monitoring (inlet and exhaust), extension cable package, OmniControl, horizontal version, operating fluids, electronic drive options (box version, switch-cabinet mounting plate, without drive electronics), cooling options (convection, active-air, water).

Section-by-Section Technical Breakdown

pp. 1
Product Highlights and Options

Overview of key selling points: reliability via integrated sensor condition monitoring, high pumping speed with best performance-to-size ratio, and efficiency via IE5 canned synchronous motor, variable speed drive, optimized rotors and no shaft seals. Lists available accessories, spare parts and options.

  • Condition monitoring via integrated sensors for high up-time
  • Hermetically sealed IE5 synchronous motor, canned motor design, no shaft seals
  • Variable speed drive and optimized rotor geometries
  • Options: Profinet converter, barrier gas kit (plastic/stainless steel), gear chamber evacuation, spray-lance flushing device, inlet/exhaust temperature and pressure monitoring, extension cable package, OmniControl, horizontal version
  • Electronic drive options: box version, mounting plate for switch cabinet integration, or without drive electronics
  • Cooling options: convection, active-air, water cooling
pp. 2-3
Technical Data

Tabulated specifications for the three models covering pumping speed, rotational speed, differential pressure limits, flanges, electrical data, drive unit, interfaces and dimensions/weight.

  • Nominal pumping speed: 890-2700 m³/h (2704), 890-4440 m³/h (4504), 890-6220 m³/h (6204)
  • Rotational speed: 1500-4500 rpm (2704), 1500-7500 rpm (4504), 1500-10500 rpm (6204)
  • Max differential pressure at max speed: 35 hPa (2704), 17 hPa (4504), 10 hPa (6204); all 50 hPa at min speed
  • Main and secondary flanges all: DN 160 ISO-F | DN 150 PN 16
  • Input voltage: 380-480 V AC (±10%), 50/60 Hz; three-phase motor with PTC protection
  • Rated power at full speed: 3.5 kW (2704), 5.5 kW (4504), 7.5 kW (6204)
  • Electronic drive unit RC 7500; recommended mains fuse 25 A; I/O: PV.can, RS485
  • Active air cooling; ambient temperature 5-40 °C
  • Shipping temperature -10 to 40 °C; sound pressure level (EN ISO 2151) at 1 hPa inlet: 62 dB(A) (2704), 65 dB(A) (4504/6204)
  • Operating fluid D2, fill 3.2 l; protection IP54 / type 12
  • Integral leak rate 1E-06 Pa·m³/s; dimensions 1122 x 430 x 354 mm; weight approx. 280 kg (all models)

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Max differential pressure at maximum rotational speed is 35 hPa (HiLobe 2704), 17 hPa (4504) and 10 hPa (6204) p.2 ↗ Select a smaller model when a higher pressure differential must be tolerated at full speed; larger pumps need lower differential or reduced speed whole series (model-specific values)
All models allow max 50 hPa differential pressure at minimum rotational speed (1500 rpm) p.2 ↗ Operating at reduced speed permits higher differential pressures, useful during pump-down/startup whole series
Rotational speed ranges: 1500-4500 rpm (2704), 1500-7500 rpm (4504), 1500-10500 rpm (6204) p.2 ↗ Variable speed drive allows matching pumping speed to process; speed range defines adjustable throughput whole series
Inlet and outlet flanges are DN 160 ISO-F | DN 150 PN 16 on both main and secondary sides for all models p.2 ↗ Identical connections on suction and exhaust simplify piping design and allow both vacuum (ISO-F) and pressure (PN16) flange systems whole series
Input voltage 380-480 V AC (±10%), 50/60 Hz, recommended mains fuse 25 A p.2 ↗ Size supply cabling and breaker accordingly; fuse rating governs installation protection whole series
Rated motor power at full rotational speed: 3.5 kW (2704), 5.5 kW (4504), 7.5 kW (6204) p.2 ↗ Defines electrical load and energy budget per model whole series
Motor is a hermetically sealed IE5 synchronous canned motor with no shaft seals; motor protection via PTC p.1 ↗ Eliminates shaft-seal leak paths (integral leak rate 1E-06 Pa·m³/s); PTC sensors must be wired into the motor protection circuit whole series
Electronic drive unit is RC 7500 with I/O interfaces PV.can and RS485; Profinet converter available as option p.1 ↗ Plan control integration via RS485/PV.can or add Profinet converter for PLC networks whole series
Standard cooling is active air cooling; convection and water cooling are options p.1 ↗ Convection cooling enables sites without compressed air/fans; water cooling for high-duty cycles or confined spaces whole series
Ambient temperature range 5-40 °C; shipping/storage temperature -10 to 40 °C p.2 ↗ Ensure installation location stays within 5-40 °C; storage before commissioning may be colder but not below -10 °C whole series
Sound pressure level (EN ISO 2151) at 1 hPa inlet pressure: 62 dB(A) for 2704, 65 dB(A) for 4504/6204 p.3 ↗ Noise assessment for workplace planning; all models below typical 80 dB(A) action threshold whole series
Operating fluid is Pfeiffer D2 with 3.2 l filling volume for all models p.3 ↗ Stock D2 operating fluid for commissioning and oil changes; fixed fill volume simplifies maintenance planning whole series
Protection degree IP54 / type 12 p.3 ↗ Suitable for dusty indoor industrial environments; not for wash-down or outdoor unprotected use whole series
Integral leak rate 1E-06 Pa·m³/s p.3 ↗ Supports high-vacuum applications as booster stage; helium-tightness class to consider in leak-rate budgets whole series
All three models share identical footprint 1122 x 430 x 354 mm and weight approx. 280 kg p.3 ↗ One mounting design and lifting arrangement covers all three models; supports footprint standardization whole series
Options include barrier gas kit (plastic or stainless steel), gear chamber evacuation, spray-lance flushing device, and inlet/exhaust temperature and pressure monitoring p.1 ↗ For particulate or condensable process loads, order barrier gas kit and flushing device; monitoring option enables predictive maintenance whole series