COBRA DS 3010 G — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Busch COBRA DS 3010 G and DS 3161 C dry screw vacuum pumps — integrated pump systems combining a screw backing pump (15 kW, 3600 min⁻¹) with a vacuum booster (15 kW, 5400 min⁻¹) on a compact base frame with canned motor and indirect water cooling. Optional powder process version available only for DS 3010 G and DS 3161 C; optional tantal coating. Intended for chemical vapor deposition, rapid thermal processing, and atomic layer deposition.
Section-by-Section Technical Breakdown
The COBRA DS 3010/3161 C/G are high-performance dry screw vacuum pumps with an advanced screw design and an integrated vacuum booster, targeting semiconductor-type processes such as CVD, RTP, and ALD. The design emphasizes low cost of ownership, long service intervals, high hydrogen throughput, and efficient indirect water cooling. The backing pump and booster are combined on a compact base frame with a directly mounted canned motor.
- Advanced screw design with excellent running qualities
- Integrated vacuum booster on compact base frame
- Suited for chemical vapor deposition, rapid thermal processing, atomic layer deposition
- Efficient indirect water cooling; high hydrogen throughput
- Optional powder process version (only for DS 3010 G and DS 3161 C)
- Optional tantal coating
Both models deliver 3200 m³/h nominal pumping speed and 0.001 hPa ultimate pressure (air at 20°C, ±10% tolerance), with identical motor ratings of 15 kW for the backing pump and 15 kW for the booster. The DS 3010 G weighs approx. 1500 kg (1420 x 722 x 1452 mm) while the DS 3161 C is lighter and more compact at approx. 1375 kg (1316 x 633 x 1249 mm). Cooling requires min. 10 l/min water; purge nitrogen usage is 0–200 l/min.
- Nominal pumping speed: 3200 m³/h (both models)
- Ultimate pressure: 0.001 hPa (mbar)
- Motor ratings: 15 kW backing pump, 15 kW vacuum booster (both models)
- Power consumption at ultimate pressure / idle mode: 11.8 / 9.9 kW
- Motor speeds: 3600 min⁻¹ (backing pump), 5400 min⁻¹ (booster)
- Sound pressure level < 75 dB(A) per ISO 2151 (KpA = 3 dB)
- Water consumption: min. 10 l/min; nitrogen consumption: 0–200 l/min
- Gas inlet/outlet: DN 160 / DN 63
- DS 3010 G: 1500 kg, 1420 x 722 x 1452 mm; DS 3161 C: 1375 kg, 1316 x 633 x 1249 mm
- Pumping speed curves based on air at 20°C, tolerance ± 10%
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Nominal pumping speed is 3200 m³/h for both COBRA DS 3010 G and DS 3161 C, with ultimate pressure of 0.001 hPa (mbar). p.2 ↗ | Both models can be treated as performance-equivalent in pump-down calculations; selection can be driven by footprint, weight, and options rather than throughput. | Both DS 3010 G and DS 3161 C |
| Pumping speed data is measured with air at 20°C with a tolerance of ±10%. p.2 ↗ | Size the vacuum system with a 10% margin; actual performance with process gases or different temperatures may differ from catalog curves. | Both models |
| Backing pump motor is 15 kW at 3600 min⁻¹ and the vacuum booster motor is 15 kW at 5400 min⁻¹ (total 30 kW nominal). p.2 ↗ | Electrical supply sizing must account for 30 kW of connected motor load across two separately driven stages. | Both models |
| Power consumption at ultimate pressure is 11.8 kW and in idle mode 9.9 kW. p.2 ↗ | Operating cost and heat load estimates should use ~12 kW continuous draw at ultimate pressure, not the 30 kW nominal motor rating. | Both models |
| Cooling water consumption is a minimum of 10 l/min via indirect water cooling. p.2 ↗ | Facility cooling loop must guarantee ≥10 l/min continuous flow; no oil-based cooling is involved (dry pump with canned motor). | Both models |
| Nitrogen consumption range is 0–200 l/min. p.2 ↗ | Purge gas supply and mass flow controller should be dimensioned up to 200 l/min; processes can run without purge at the low end. | Both models |
| Sound pressure level is below 75 dB(A) per ISO 2151 with KpA = 3 dB. p.2 ↗ | Suitable for installation without dedicated acoustic enclosures in most cleanroom/lab noise budgets; uncertainty of measurement is ±3 dB. | Both models |
| Gas connections are DN 160 inlet and DN 63 outlet for both models. p.2 ↗ | Piping and flange hardware must match DN 160 (ISO/ISO-K style) on the process side and DN 63 on the exhaust side. | Both models |
| DS 3010 G weighs approx. 1500 kg with dimensions 1420 x 722 x 1452 mm; DS 3161 C weighs approx. 1375 kg with 1316 x 633 x 1249 mm. p.2 ↗ | Floor loading and rigging plans must support ~1.5 t; the DS 3161 C saves ~125 kg and significant footprint (about 104 mm less length, 89 mm less width, 203 mm less height). | DS 3010 G and DS 3161 C respectively |
| A powder process version is available as an option, only for the DS 3010 G and DS 3161 C variants. p.1 ↗ | For processes generating particulates/byproducts, specify the powder process variant at ordering time; it is not offered for the DS 3010 C/G other combinations. | DS 3010 G and DS 3161 C only |
| Tantal coating is available as an option. p.1 ↗ | For corrosive semiconductor process chemistries, order the tantal-coated version to improve material compatibility of wetted surfaces. | Both models |
| The pump uses a canned motor directly mounted, with the backing pump and vacuum booster combined on one base frame. p.1 ↗ | No shaft seals/coupling alignment between motor and pump; installation is a single-frame placement, simplifying alignment and leak-tightness at the pump-motor interface. | Both models |