HiLobe 1004 — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum HiLobe series vacuum boosters (Roots-type), covering three models: HiLobe 1004, HiLobe 1304, and HiLobe 2104. Brochure includes accessories/options list (Profinet converter, barrier gas kit, OmniControl, horizontal version, drive and cooling options), dimensional drawings, pumping speed curves (50/60 Hz), and technical data tables.
Section-by-Section Technical Breakdown
Highlights the HiLobe key selling points: condition monitoring via integrated sensors, high pumping speed with best performance-to-size ratio, and efficiency via hermetically sealed IE5 canned motor without shaft seals, variable speed drive and extended maintenance intervals. Lists available accessories and options.
- Intelligent condition monitoring via integrated sensors for high up-time
- Hermetically sealed synchronous motor (IE5), canned motor design, no shaft seals
- Options: Profinet converter, barrier gas kit (plastic or stainless steel), gear chamber evacuation, flushing device (spray lance)
- Temperature and pressure monitoring (inlet and exhaust side), extension cable package, OmniControl
- Horizontal version, operating fluids available
- Electronic drive options: box version, mounting plate for switch cabinet integration, without drive electronics
- Cooling options: convection cooling, active-air cooling, water cooling
Provides dimensional drawings and pumping speed curves at 50 Hz and 60 Hz for HiLobe 1004, 1304 and 2104. This section graphically presents pump dimensions and pumping speed behavior.
- Dimensional drawings for HiLobe 1004, 1304, 2104
- Pumping speed curves shown for 50 Hz (solid) and 60 Hz (dashed) operation
Comprehensive specification table covering pumping speed, rotational speed, differential pressure limits, flanges, electrical data, drive unit, cooling, environment, noise, operating fluid, leak rate, dimensions and weight for all three models.
- Nominal pumping speed: 1004: 250-1050 m³/h; 1304: 260-1300 m³/h; 2104: 260-2100 m³/h
- Rotational speed: 1004: 1500-6000 rpm; 1304: 1500-7500 rpm; 2104: 1500-12000 rpm
- Max differential pressure: 52 hPa (1004), 35 hPa (1304), 12 hPa (2104) at max speed; 75 hPa for all at min speed
- Flanges: DN 100 ISO-F or DN 100 PN 16 on inlet and outlet for all models
- Input voltage: 380-480 V AC (±10%), 50/60 Hz; three-phase motor with PTC protection
- Rated power at full speed: 2 kW (1004), 2.5 kW (1304), 3.5 kW (2104)
- Electronic drive unit RC 5500, recommended mains fuse 16 A, interfaces PV.can and RS485
- Active air cooling, ambient temperature 5-40 °C, shipping temperature -10-40 °C
- Sound pressure level (EN ISO 2151) at 1 hPa inlet pressure: 67/68/69 dB(A)
- Operating fluid D2, filling 0.65 l; IP54 / type 12; leak rate 1E-06 Pa·m³/s
- Dimensions 875 x 282 x 240 mm, weight approx. 115 kg (all models)
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Max differential pressure at max rotational speed differs sharply by model: 52 hPa (HiLobe 1004), 35 hPa (HiLobe 1304), 12 hPa (HiLobe 2104); at min rotational speed all models allow up to 75 hPa. p.2 ↗ | For high-pressure-ratio duty the 1004 tolerates much higher Δp at speed; if the process requires >12 hPa Δp during fast operation, the 2104 must be operated at reduced speed. | All models; differential pressure limits are model-specific |
| HiLobe 2104 reaches 2100 m³/h at up to 12,000 rpm; HiLobe 1004 delivers 1050 m³/h at 6,000 rpm and HiLobe 1304 delivers 1300 m³/h at 7,500 rpm. p.2 ↗ | Selecting the 2104 doubles pumping speed without changing footprint (identical 875 x 282 x 240 mm envelope), but at the cost of a much lower max Δp at full speed. | All three models |
| Input voltage is 380-480 V AC (±10%), 50/60 Hz, with recommended mains fuse capacity of 16 A. p.2 ↗ | Standard 400/480 V industrial supply is sufficient; specify a 16 A branch protection fuse per pump with RC 5500 drive. | Whole series |
| Rated motor power at full rotational speed: 2 kW (1004), 2.5 kW (1304), 3.5 kW (2104); three-phase synchronous motor (IE5) with PTC protection. p.2 ↗ | Size supply cabling and drive sizing per model power; PTC sensors must be wired into the drive/motor protection circuit for thermal monitoring. | Whole series; power values per model |
| The motor is a hermetically sealed canned-motor design (IE5) with no shaft seals. p.1 ↗ | Eliminates shaft seal leak paths and shaft-seal maintenance; contributes to the specified 1E-06 Pa·m³/s integral leak rate. | Whole series |
| Electronic drive unit is the RC 5500 for all models, with I/O interfaces PV.can and RS485. p.2 ↗ | Plan control integration around PV.can/RS485; add the optional Profinet converter if the plant uses Profinet. | Whole series |
| Ambient temperature range is 5-40 °C; shipping/storage temperature is -10-40 °C. p.2 ↗ | Provide heating or location selection for installations below 5 °C; freeze protection is not specified for operation. | Whole series |
| Standard cooling method is active air cooling; optional cooling variants are convection cooling and water cooling. p.1 ↗ | Water or convection cooling options can be ordered for hot environments or noise-restricted installations; active air cooling is the default configuration. | Whole series |
| Operating fluid is D2 with a filling volume of 0.65 l per pump. p.3 ↗ | Stock D2 oil for commissioning and maintenance; 0.65 l is the refill quantity per gearbox/oil chamber. | Whole series |
| Protection degree IP54 / type 12; integral leak rate 1E-06 Pa·m³/s. p.3 ↗ | Suitable for dusty industrial cabinets environments (type 12); leak rate supports demanding vacuum process tightness requirements. | Whole series |
| Sound pressure level per EN ISO 2151 at 1 hPa inlet pressure: 67 dB(A) (1004), 68 dB(A) (1304), 69 dB(A) (2104). p.3 ↗ | Below typical 80 dB(A) thresholds; hearing protection generally not required for the pump alone, but system-level noise should be verified. | All models; values per model |
| Inlet and outlet flanges are DN 100 ISO-F or DN 100 PN 16 for all three models. p.2 ↗ | Identical connections across the series allow model swaps without changing pipework; PN 16 option for pressure-rated (e.g. barrier gas) installations. | Whole series |
| Dimensions 875 x 282 x 240 mm and weight approx. 115 kg are identical for all three models. p.3 ↗ | Footprint, skid layout and lifting equipment can be standardized across the range; ~115 kg requires two-person or hoist handling. | Whole series |
| Available accessories include barrier gas kit (plastic or stainless steel), gear chamber evacuation, flushing device (spray lance), temperature and pressure monitoring on inlet and exhaust side, and a horizontal version. p.1 ↗ | Order the barrier gas kit for processes with particles/condensables; gear chamber evacuation and flushing options extend suitability for harsh process gases; specify horizontal version at ordering time. | Whole series |
| Drive electronics can be ordered as box version, mounting plate for switch cabinet integration, or without drive electronics. p.1 ↗ | Choose 'without drive electronics' only when a third-party VFD with matching control capability is used; cabinet-integration option saves floor space in electrical rooms. | Whole series |