Induztr
Engineering Digest Document Viewer Related Models

ACP 90 — product leaflet

Technical Reference Summary

Covered Models & Document Scope

Pfeiffer Vacuum ACP 90 multi-stage Roots vacuum pump, dry (maintenance-free) design. Document is a 2-page datasheet covering one model; available options/accessories listed: dust filter, external silencer, isolation valve, preventive maintenance packages, corrosive gas version. Pumping speed curves given for 50 Hz and 60 Hz operation.

Section-by-Section Technical Breakdown

pp. 1
Product Features

Highlights of the ACP 90: efficiency via an IE5 permanent magnet motor with low power consumption, high pumping speed at high pressures suited to large volumes and frequent pump-downs, high water vapor capacity, and reliability with high-quality bearings and near maintenance-free operation.

  • Low power consumption with IE5 permanent magnet motor
  • High pumping speed at high pressures — ideal for large volumes and frequent pump-downs
  • High water vapor capacity
  • Nearly maintenance-free, high-quality bearings, long life cycle
pp. 1
Accessories, Spare Parts and Options

Lists optional accessories and variants available for the ACP 90, including protection and process adaptations.

  • Dust filter
  • External silencer
  • Isolation valve
  • Preventive maintenance packages
  • Corrosive gas version
pp. 2
Technical Data

Complete performance and installation data: pumping speed, ultimate pressures (with/without gas ballast), power figures, supply voltages, connections, dimensions and weight for the ACP 90.

  • Max. pumping speed 88 m³/h (50 Hz and 60 Hz curves provided)
  • Ultimate pressure 3·10⁻² mbar without dilution; 1.6·10⁻¹ mbar with gas-ballast valve
  • Max. continuous inlet pressure 1013 mbar (atmospheric)
  • Max. water pumping capacity 2400 g/h (depending on configuration)
  • Power consumption 1.3 kW at ultimate pressure, max. 2 kW
  • Supply: 200–240 VAC 1-/2-phase; 380–480 VAC 3-phase
  • Air cooled; sound pressure level <65 dB(A) at ultimate pressure
  • Flanges: DN 40 ISO-KF inlet and outlet
  • Dimensions 671 x 319 x 324 mm; weight 75 kg; max. leak rate <5·10⁻⁶ hPa·l/s

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Max. pumping speed is 88 m³/h p.90 ↗ Size the backing/foreline and pump-down time calculations around 88 m³/h; performance differs between 50 Hz and 60 Hz per the pumping speed curves. ACP 90
Ultimate pressure is 3·10⁻² mbar without dilution and 1.6·10⁻¹ mbar with gas-ballast valve open p.90 ↗ Using gas ballast for vapor handling degrades achievable base pressure ~5x; select based on whether vapor purge or low ultimate pressure is the priority. ACP 90
Max. continuous inlet pressure is 1013 mbar p.90 ↗ Pump can start and run from atmospheric pressure without a bypass or soft-start staging — suitable for direct pump-down of vented vessels. ACP 90
Max. water pumping capacity is 2400 g/h, depending on configuration p.90 ↗ For condensable-heavy processes, verify the configuration supports this capacity; consider gas ballast operation (which raises ultimate pressure). ACP 90 (configuration-dependent)
Power consumption is 1.3 kW at ultimate pressure, 2 kW max p.90 ↗ Dimension supply/breaker sizing for 2 kW peak; the IE5 PM motor keeps running power low at base pressure. ACP 90
Supply voltage is 200–240 VAC (1-/2-phase) or 380–480 VAC (3-phase) p.90 ↗ Check site power availability before ordering; both single-phase and three-phase installations are supported. ACP 90
Sound pressure level is <65 dB(A) at ultimate pressure p.90 ↗ Acceptable for lab/close-proximity installation without mandatory acoustic enclosure; external silencer available as option for further reduction. ACP 90
Cooling method is air cooling p.90 ↗ Ensure adequate ambient airflow/clearance at installation; no cooling water circuit required. ACP 90
Max. leak rate is <5·10⁻⁶ hPa·l/s p.90 ↗ Tight enough for clean/high-vacuum train integration; use this as acceptance criterion for leak checking after installation. ACP 90
Inlet and outlet connections are both DN 40 ISO-KF p.90 ↗ Simplify installation with standard KF40 clamps, centering rings and O-rings; same fitting on foreline side. ACP 90
Dimensions 671 x 319 x 324 mm (L x W x H), weight 75 kg p.90 ↗ Plan mounting frame and lifting/handling for 75 kg; footprint fits compact skids. ACP 90
A corrosive gas version and preventive maintenance packages are available p.90 ↗ Specify the corrosive-gas variant for aggressive process gases rather than modifying the standard pump; plan maintenance via the PM packages. ACP 90 (option)
Pumping speed curves are provided separately for 50 Hz and 60 Hz supply frequencies p.90 ↗ Use the correct frequency curve for pump-down calculations per the installation region/mains supply. ACP 90

Related models