c10g-e102
Technical Reference Summary
Covered Models & Document Scope
Application booklet 'The Coming Hydrogen Energy Society' covering Shimadzu analytical and testing instruments for hydrogen-related analyses: Gas Chromatograph (Brevis GC-2050, Nexis GC-2030), Gas Chromatograph Mass Spectrometer, Fourier Transform Infrared Spectrophotometer, Ion Chromatograph / High Performance Liquid Chromatograph, Precision Universal Testing Machine, Microfocus X-ray CT System, Fatigue and Endurance Testing Machine, Transportable Gas Analyzer, Electron Probe Microanalyzer, X-Ray Photoelectron Spectrometer, Differential Scanning Calorimeter, Total Organic Carbon Analyzer, Ultrasonic Optical Flaw Detector. No model-specific ordering codes or part numbers are printed.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Detectable impurity (CO2) | 2 p.3 ↗ | Analysis of impurities in hydrogen, GC-MS/IC/HPLC/FTIR with BID/TCD/FID/SCD |
| Detectable impurity (CO) | 0.2 p.3 ↗ | Analysis of impurities in hydrogen, GC-MS/IC/HPLC/FTIR with BID/TCD/FID/SCD |
| Molecular weight (Hydrogen) | 2.0 p.4 ↗ | Hydrogen |
| Molecular weight (Liquid Hydrogen) | 2.0 p.4 ↗ | Liquid Hydrogen |
| Molecular weight (Ammonia) | 17.0 p.4 ↗ | Ammonia |
| Molecular weight (Formic Acid) | 46.0 p.4 ↗ | Formic Acid |
| H2 content | 100.0 wt % p.4 ↗ | Hydrogen |
| H2 content | 100.0 wt % p.4 ↗ | Liquid Hydrogen |
| H2 content | 6.2 wt % p.4 ↗ | Ammonia |
| H2 content | 17.8 wt % p.4 ↗ | Formic Acid |
| Boiling point | -253 °C p.4 ↗ | Hydrogen |
| Boiling point | -33 °C p.4 ↗ | Ammonia |
| Boiling point | 101 °C p.4 ↗ | Formic Acid |
| Sulfur compound concentration (average) | 3.876 ppb p.6 ↗ | GC-SCD, 10 replicates |
| Sulfur compound peak area (average) | 51105 p.6 ↗ | GC-SCD, 10 replicates |
| Repeatability (%RSD) | 1.23 % p.6 ↗ | GC-SCD, 10 replicates |
| Gas composition (H2) | 37.3 % p.10 ↗ | Before/after ammonia synthesis |
| Gas composition (N2) | 31.3 % p.10 ↗ | Before/after ammonia synthesis |
| Gas composition (NH3) | 31.4 % p.10 ↗ | Before/after ammonia synthesis |
| Upper compression | 30 p.16 ↗ | Compression fatigue test of gasket |
| Stroke | 12.3 µm p.16 ↗ | Compression fatigue test of gasket |
| Stroke | 32.1 µm p.16 ↗ | Compression fatigue test of gasket |
| Displacement gauge | 7.4 µm p.16 ↗ | Compression fatigue test of gasket |
| Displacement gauge | 12.4 µm p.16 ↗ | Compression fatigue test of gasket |
| Pt(0) binding energy | 71.8 eV p.20 ↗ | MEA sample A, XPS |
Operating Limits
- Minimum detectable CO concentration: 0.2 p.3 ↗
- Minimum detectable CO2 concentration: 2 p.3 ↗
- Boiling point of hydrogen: -253 °C p.4 ↗
- Boiling point of ammonia: -33 °C p.4 ↗
- Boiling point of formic acid: 101 °C p.4 ↗