Agilent Technologies 1220 Infinity II LC System
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 1220 Infinity II LC System

Agilent Technologies 1220 Infinity II LC System — Liquid chromatography.

The 1220 Infinity II LC System is a compact, integrated HPLC platform for analytical-scale liquid chromatography, including cannabinoid potency testing in industrial hemp. It is positioned below the 1260 Infinity II series, which adds higher-pressure and bio-inert variants. The system is used for routine quantification and method development where a simple, self-contained LC is sufficient.

Agilent Technologies Analytical HPLC Systems Series — Model Comparison & Selection

Model Flow rate, liter/minuteSample volume, milliliterColumn temperature, °CData rate, HzOperating altitude, mWeight, kg
1220 Infinity II LC System Current —15080200030
1260 Infinity III LC System 0.60.00540120——
1260 Infinity III Prime LC System 9×10⁻⁴0.0024040300011.5

Full specifications

Core Performance & Functional Specifications
Wavelength range 190...600 nm
Centrifugation Speed 5000 rpm
Column temperature 50 °C
Data Rate 80 Hz
Extraction Solvent Volume 20 mL
Filter Membrane Diameter 47 mm
Filter Membrane Pore Size 0.2 μm
Filter Pore Size 0.45 μm
Internal Volume 6 µL
Light source Deuterium lamp
Linearity 2 limit
Maximum Sampling Rate 80 Hz
Ptfe Frits Per Pm Kit 5 pk
Sample Capacity 100 tray
Sample volume 1 microvial
Solvent Bottle Volume 1 L
Solvent Filtration Assembly Flask Volume 1 L
Solvent Filtration Assembly Funnel Volume 250 mL
Solvent Inlet Filter Pore Size 10 μm
Temperature Accuracy 0.8 °C
Well-plate Closing Mat Quantity 50 pk
Well-plate Volume 0.5 mL
Target compounds quantified mfr 11 ytocannabinoids
Target cannabinoid mfr Cannabidivarin Cannabidivarin
Regulatory THC limit for industrial hemp mfr 0.3
Total THC calculation factor mfr 0.877
Quick Connect heat exchanger flow rate mfr 2.5 mL/min
Capillary dimensions mfr 0.12 mm
Preventive maintenance cost reduction mfr 30
Pump seals per PM kit mfr 4
Seal cap assembly sets per PM kit mfr 2
Gold seals for outlet valve per PM kit mfr 2
Seal washes per PM kit mfr 4
Solvent bottles per convenience kit mfr 3 amber
Safety standards mfr IEC, CSA, UL UL
Hydraulic system mfr Dual plunger in series pump with proprietary ser
Flow range mfr 0.001...10 mL/min
Flow precision mfr 0.07 greater
Flow accuracy mfr 1 greater
Pressure operating range mfr 40 mL/min
Pressure pulsation mfr 2 greater
Compressibility compensation mfr User-selectable, based on mobile phase compressi
Recommended pH mfr 1.0...12.5
Gradient formation (optional) mfr Low pressure binary mixing/gradient capability u
Delay volume mfr 600...900 pressure
Composition precision mfr 0.2 greater
Gradient formation mfr Low pressure binary mixing/gradient capability u
Injection range mfr 0.1...100 increments
Replicate injections mfr 1...99 vial
Carry over mfr 0.1 cleaning
Injection cycle time mfr 50 volume
Column capacity mfr 1 cm
Detection type mfr 1024 array
Wavelength accuracy mfr 1 nm
Flow cells mfr 14 maximum
Number of signals mfr 8
Flow cell mfr 13 maximum
Time programmable mfr Wavelength, polarity, peak width, lamp bandwidth
Number of target cannabinoids mfr 11
Precision mfr 1 μL
extraction shake time mfr 10 minutes
oil aliquot volume mfr 100 μL
oil dilution flask volume mfr 10 mL
ethanol volume for oil dilution mfr 8 mL
second dilution aliquot mfr 100 μL
second dilution solvent volume mfr 900 μL
autosampler vial volume mfr 2 mL
Control and data evaluation mfr Agilent EZChrom Compact, Agilent ChemStation, Ag
Communications mfr -232 LAN
GLP features mfr Early maintenance feedback , electronic records
IP address: mfr 192.168.254.11
Subnet Mask: mfr 255.255.255.0
Default Gateway mfr not specified specified
? mfr displays syntax and descriptions of commands com
ip <x.x.x.x> mfr sets new ip address address
sm <x.x.x.x> mfr sets new subnet mask mask
gw <x.x.x.x> mfr sets new default gateway gateway
exit mfr exits shell and saves all changes changes
Recommended flow mfr 0.2...10.0 mL/min
Dimensions, Weight & Mechanical Design
Slit Width 6.5 range
Weight 30 kg
Dimensions (height × width × depth) mfr 640 mm
Diode width mfr 1 nm
Electrical, Power & Drive Specifications
Line voltage mfr 100...240
Line frequency mfr 50
Power consumption mfr 240 BTU
Interfaces, Connections & Control
Quick Turn Fitting Pressure Limit 800 bar
Solvent bottle thread mfr 45
Materials, Media & Process Compatibility
Sample weight (plant material) mfr 200 mg
Recommended pH range mfr 1.0...12.5
Sample viscosity range mfr 0.2...50 cp
sample weight (plant material) mfr 200 mg
Operating Conditions, Environment & Protection
Noise 1 nm
Operating Altitude 2000 m
Humidity mfr 95 °C
Non-operating altitude mfr 4600 m
Short term noise (ASTM) mfr 0.25 nm
Short term noise (ASTM) Single and Multi-Wavelength mfr 0.7 nm
Standards, Safety & General Data
Instrument part number mfr 8417 AA

Description

Construction and positioning

Behavior and application scope

Installation and operation

Integration & Operating Notes

Maintenance
Preventive maintenance kit includes pump seals and seal washes

The PM kit contains 2 pump seals, 2 seal cap assembly sets, 2 gold seals for the outlet valve, and 4 seal washes. Plan seal replacement according to the maintenance schedule; the kit is not part of the base delivery and must be ordered separately.

Flyer LC Supplies Recommendations 5994-5755EN

Selection & Integration Q&A

When should I choose the 1220 Infinity II LC System instead of a 1260 Infinity II sibling such as the amino acid analysis or bio-inert purification system?

Choose the 1220 for routine analytical HPLC, including cannabinoid potency testing in hemp, where a compact integrated system is sufficient. The 1260 siblings add specialized capabilities: amino acid analysis, bio-inert flow paths, or analytical-scale purification. Select the 1260 when your method requires those dedicated configurations.

What consumables and fittings are required to connect the 1220 Infinity II LC System to my solvent supply and column?

Use 10 µm solvent inlet filters, 47 mm/0.2 µm filter membranes for mobile-phase filtration, and quick-turn fittings rated to 800 bar. Solvent bottles are 1 L with a 45 mm thread. Capillaries of 0.17 mm ID are listed. These supplies are not included in the base delivery and must be ordered separately.

What are the mounting and environmental limits for the 1220 Infinity II LC System?

The supplied documents do not specify mounting, ambient temperature, humidity, or duty-cycle limits for this model. The only temperature fact is a 50 °C column temperature, which is an application condition, not a system limit. Consult the site preparation guide or Agilent for environmental requirements.

What maintenance parts are needed for the 1220 Infinity II LC System and are they included with the instrument?

The preventive maintenance kit includes 2 pump seals, 2 seal cap assembly sets, 2 gold seals for the outlet valve, and 4 seal washes. These are not included in the base delivery. Also stock 10 µm inlet filters and 47 mm/0.2 µm filter membranes. No service interval is stated in the supplied documents.

Dimensional Drawings & Technical Documentation

Dimensional drawings

performance curve

Click drawing to inspect vector dimensions

Technical documentation

PDF
Quantification of Cannabinoids
Manual ·306,7 КБ ·4 pp.
View PDF
PDF
Agilent InfinityLab LC Series 1220 Infinity II LC System User Manual
Manual ·398 pp.
View PDF