Agilent Technologies 1260 Infinity Amino Acid Analysis System
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 1260 Infinity Amino Acid Analysis System

Agilent Technologies 1260 Infinity Amino Acid Analysis System — Liquid chromatography.

The 1260 Infinity Amino Acid Analysis System is a dedicated LC configuration built around the 1260 Infinity II Vialsampler or Multisampler with a 100 µL analytical head and 100 µL loop, paired with an AdvanceBio AAA column (3.0 mm × 2.7 µm) and guard (4.6 mm). It performs automated OPA/FMOC derivatization at room temperature with fluorescence detection at 340/260 nm excitation and a 10-stage PMT gain, using a 0.4 M borate buffer at pH 10.2 and 2.5 mg/mL FMOC reagent. This modification is the application-specific amino acid workflow, distinct from the general-purpose Bio-Inert and Prime Bio siblings.

Agilent Technologies Bio LC Solutions Series — Model Comparison & Selection

Model Flow rate, liter/minuteMass rangeMax pressure, megapascalPumping speed, m³/hWavelength rangeSample volume, milliliter
1260 Infinity Amino Acid Analysis System Current ——————
1260 Infinity III Bio-Inert LC System 0.01—606×10⁻⁴190...950—
1290 Infinity III Bio LC | Biocompatible UHPLC system —300...3,200———0.005

Full specifications

Core Performance & Functional Specifications
Analytical Head Volume 100 µL
Loop Volume 100 µL
Vial Volume 2 mL
AdvanceBio AAA LC column dimensions mfr 3.0 mm
AdvanceBio AAA LC column particle size mfr 2.7 μm
AdvanceBio AAA guard column dimensions mfr 4.6 mm
Borate buffer concentration mfr 0.4 M
Borate buffer pH mfr 10.2
FMOC reagent concentration mfr 2.5 mg/mL
DTDPA reagent quantity mfr 5 g
Fluorescence detection excitation (primary) mfr 340 nm
Fluorescence detection excitation (secondary) mfr 260 nm
PMT gain mfr 10
Gradient %B at 0.35 min mfr 2
Gradient %B at 13.4 min mfr 57
Sample thermostat option mfr 101
Diluent draw volume mfr 80 μL
Wait time mfr 0.6 minutes
Column mfr 120
Calibration concentration levels mfr 20
Caffeine stock solution concentration mfr 100 μg/mL
Calibration function slope (Multisampler 100 μL, manual) mfr 27.85
Calibration function slope (Multisampler 100 μL, autosampler) mfr 27.64
Calibration function slope (Vialsampler 100 μL, manual) mfr 27.76
Calibration function slope (Vialsampler 100 μL, autosampler) mfr 27.65
Calibration function slope (Multisampler 900 μL, manual) mfr 27.69
Calibration function slope (Multisampler 900 μL, autosampler) mfr 27.53
Calibration function R2 (Multisampler 100 μL, manual) mfr 0.99999
Calibration function R2 (Multisampler 100 μL, autosampler) mfr 1.00000
Calibration function R2 (Vialsampler 100 μL, manual) mfr 0.99999
Calibration function R2 (Vialsampler 100 μL, autosampler) mfr 0.99999
Calibration function R2 (Multisampler 900 μL, manual) mfr 0.99999
Calibration function R2 (Multisampler 900 μL, autosampler) mfr 1.00000
Electrical, Power & Drive Specifications
Mobile phase A composition mfr 10
Operating Conditions, Environment & Protection
Signal-to-noise acceptance criterion mfr 3
Standards, Safety & General Data
AA standard concentration mfr 1 nmol/μL
AA standard quantity mfr 250 pmol

Description

Construction and series positioning

Derivatization and separation behavior

Installation and operation

Integration & Operating Notes

Mounting
Column and guard are separate items with distinct dimensions

The AdvanceBio AAA LC column is 3.0 mm with 2.7 µm particles, while the guard column is 4.6 mm; the guard must be installed on the matching hardware and is a consumable replaced independently of the analytical column. Confirm the column compartment (Multicolumn Thermostat G7116A) holds the 3.0 mm column format.

5991 7694EN AdvanceBio AAA How To Guide

Selection & Integration Q&A

When should I choose the 1260 Infinity Amino Acid Analysis System instead of the 1260 Infinity III Bio-Inert LC System?

Choose this AAA system when the workflow is OPA/FMOC amino acid quantification with fluorescence detection at 340/260 nm and the AdvanceBio AAA column. The Bio-Inert LC System is a general-purpose 600 bar, 10 mL/min, 190–950 nm platform for bio-inert separations, not a derivatization kit.

What sampler configuration and adjacent modules are required to run the validated calibration method?

The method is validated on a 1260 Infinity II Vialsampler (G7129C) or Multisampler (G7167A) with 100 µL analytical head and 100 µL loop, plus Flexible Pump G7104C, Multicolumn Thermostat G7116A, and Diode Array Detector HS G7117C. The Multisampler can alternatively use a 900 µL head (option #163) and 900 µL loop (option #156).

What are the sample thermostat and injector-program requirements for the serial dilution calibration?

Sample thermostat option #101 is available for the sampler. The injector program performs serial dilution with an 80 µL diluent draw and 0.6 min wait; calibration slopes are 27.85 (Multisampler 100 µL, manual) and 27.64 (autosampler), with R² of 0.99999–1.00000.

Which reagents, columns, and consumables are not included in the base instrument delivery?

Borate buffer (0.4 M, pH 10.2), FMOC reagent (2.5 mg/mL), DTDPA (5 g), amino acid standard (1 nmol/µL, 250 pmol), AdvanceBio AAA LC column (3.0 mm, 2.7 µm) and guard (4.6 mm), plus vials, caps, and septa are separate consumables ordered independently of the instrument.

Dimensional Drawings & Technical Documentation

Dimensional drawings

performance curve performance curve

Click drawing to inspect vector dimensions

Technical documentation