Agilent Technologies 1260 Infinity II Bio-SEC System
Agilent Technologies 1260 Infinity II Bio-SEC System — Liquid chromatography with Pumping speed 0.024 m³/h.
The 1260 Infinity II Bio-SEC Multidetector System is a size-exclusion chromatography platform built around a 2.1 mm × 50 mm, 1.8 µm column and a 2 µL, 3 mm path-length flow cell, configured for bio-inert operation with tolerance to 2 M NaCl, 8 M urea, 0.5 M NaOH and 0.5 M HCl. It is distinguished within the 1260 Infinity II series by its multidetector SEC configuration and 6144-sample capacity, positioning it for high-throughput aggregate and fragment analysis of proteins and biopolymers.
Agilent Technologies GPC SEC Solutions Series — Model Comparison & Selection
| Model | Pumping speed, m³/h | Sample volume, milliliter | Column particle size, µm | Column temperature, °C | Column inner diameter, mm | Column length, m |
|---|---|---|---|---|---|---|
| 1260 Infinity II Bio-SEC System Current | 0.024 | — | 1.8 | — | 2.1 | 0.05 |
| 1260 Infinity II Bio-SEC system | Biological polymer analysis | 4.8×10⁻⁵ | 0.01 | 2.7 | 30 | — | — |
| 1260 Infinity II Multidetector GPC/SEC System | — | 5...500 | — | 220 | — | — |
| 1290 Infinity II GPC/SEC system | 3.6×10⁻⁶ | 0.02 | 3 | 35 | 4.6 | 0.25 |
Full specifications
| Pumping speed | 0.400 mL/min |
| Carryover | 9 ppm |
| Column Particle Size | 1.8 µm |
| Flow Cell Volume | 2 µL |
| Sample Capacity | 6144 samples |
| Membrane pore size mfr | 0.22 μm |
| Salt concentration tolerance mfr | 2 NaCl |
| Urea concentration tolerance mfr | 8 urea |
| NaOH concentration tolerance mfr | 0.5 NaOH |
| HCl concentration tolerance mfr | 0.5 HCl |
| Column Inner Diameter | 2.1 mm |
| Column Length | 50 mm |
| Flow Cell Path Length | 3 mm |
Description
Construction and series positioning
- This model is the bio-SEC multidetector configuration of the 1260 Infinity II series; sibling models cover analytical-scale purification, amino-acid analysis and the 1220 Infinity II LC platform.
- The flow path is defined by a 2.1 mm inner-diameter, 50 mm length column with 1.8 µm particles, coupled to a 2 µL flow cell with a 3 mm path length.
- Bio-inert wetted materials are implied by the stated tolerance to 2 M NaCl, 8 M urea, 0.5 M NaOH and 0.5 M HCl; membrane pore size is 0.22 µm.
Behavior under load and in different media
- The system is specified at a pumping speed of 0.400 mL/min, with 9 ppm carryover.
- Sample capacity is 6144 samples, supporting long unattended SEC runs.
- No digitized curve points are available; retention and resolution behavior must be established per method.
Installation, connection and control
- The attached brochure covers the InfinityLab Bio LC family (1290 Infinity II Bio LC, 1260 Infinity II Prime Bio LC, 1260 Infinity II Bio-Inert LC) and SEC workflow solutions but prints no ordering codes or part numbers.
- The nucleotide application note describes a 1290 Infinity II Bio LC system with Bio Flexible Pump (G7131A), Bio Multisampler (G7137A) with Sample Thermostat (option #101), Multicolumn Thermostat (G7116B) with biocompatible heat exchanger (G7116-60071), and Variable Wavelength Detector (G7114B) with biocompatible micro flow cell (G1314-60189), controlled by OpenLab CDS 2.6 or later; these are adjacent-system references, not this model's own configuration.
Integration & Operating Notes
The stated salt and chaotrope tolerances define the wetted-path compatibility envelope. Exceeding 2 M NaCl, 8 M urea, 0.5 M NaOH or 0.5 M HCl risks damage to bio-inert components and invalid SEC results; verify mobile-phase composition before each method.
The 0.22 µm membrane pore size specification sets the filtration requirement for buffers and samples. Particulates above this rating can foul the 1.8 µm column and the 2 µL flow cell, so filter all phases before use.
Because the column particle size is 1.8 µm and the flow cell volume is only 2 µL, particulate loading is the main service driver. Establish a filter-replacement interval and column guard policy to protect resolution and detector baseline.
Selection & Integration Q&A
Choose this model when the workflow is size-exclusion with multidetector detection and bio-inert solvent tolerance (2 M NaCl, 8 M urea, 0.5 M NaOH, 0.5 M HCl) plus 6144-sample capacity. Siblings target analytical-scale purification or routine 1220 LC, not SEC multidetection.
The bio-LC reference configuration uses a Bio Flexible Pump (G7131A), Bio Multisampler (G7137A) with Sample Thermostat option #101, Multicolumn Thermostat (G7116B) with biocompatible heat exchanger (G7116-60071), and a VWD (G7114B) with biocompatible micro flow cell (G1314-60189), controlled by OpenLab CDS 2.6 or later.
No maintenance schedule is stated in the verified facts. Consumables to plan for include 0.22 µm filters and the 1.8 µm, 2.1 mm × 50 mm SEC column; the brochure prints no ordering codes, so column, filter and flow-cell part numbers must be confirmed separately.