Agilent Technologies 1290 Infinity III LC
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 1290 Infinity III LC

Agilent Technologies 1290 Infinity III LC — Liquid chromatography with Pumping speed 6×10⁻⁵ m³/h.

The 1290 Infinity II high-throughput system is a UHPLC configuration built around a 1290 Infinity II pump and autosampler, distinguished within the 1260 Infinity II GPC/SEC series by its 800 bar Quick Turn fitting pressure limit and sub-3 µm column compatibility. It is intended for fast, high-resolution separations in GPC/SEC workflows where sample throughput and method speed are the primary constraints.

Pumping speed
6×10⁻⁵ m³/h

Full specifications

Core Performance & Functional Specifications
Pumping speed 1 mL/minute
Column Particle Size 2.7 µm
Column temperature 55 °C
Drying Gas Flow 15 L/min
Filter Membrane Diameter 47 mm
Filter Membrane Pore Size 0.2 μm
Flow Rate (1220 Infinity Ii Lc) 10 mL/minute
Flow Rate (1290 Infinity Iii Lc) 5 mL/minute
Gas Flow 9 L/min
Maximum operating pressure 1300 bar
Ptfe Frits Per Pm Kit 5 pk
Sample volume 10 µL
Scan speed 4 spectra/sec
Sheath Gas Flow 11 L/min
Solvent Bottle Volume 1 L
Solvent Filtration Assembly Flask Volume 1 L
Solvent Filtration Assembly Funnel Volume 250 mL
Solvent Inlet Filter Pore Size 10 μm
Well-plate Closing Mat Quantity 50 pk
Well-plate Volume 0.5 mL
Quick Connect heat exchanger flow rate mfr 2.5 mL/min
Capillary dimensions mfr 0.12 mm
Preventive maintenance cost reduction mfr 30
Pump seals per PM kit mfr 4
Seal cap assembly sets per PM kit mfr 2
Gold seals for outlet valve per PM kit mfr 2
Seal washes per PM kit mfr 4
Solvent bottles per convenience kit mfr 3 amber
Analysis time (ACR configuration) mfr 5.1 min
Analysis time reduction with ACR mfr 30
Number of analytes mfr 125
Eluent pump flow rate mfr 0.35 mL/min
Regeneration pump flow rate mfr 0.5 mL/min
Needle wash mfr 50 O
Nebulizer pressure mfr 60 psig
Column dimensions mfr 2.1 mm
Gradient mfr 5 equilibration
Binary Pump mfr High-Speed Pump*
Quaternary Pump mfr Flexible Pump**
Solvent Preparation mfr 1260 Degasser
Solvent Delivery mfr 1260 Pump
Valve Solutions mfr InfinityLab Quick Change Valves Valves
Maximum operating pressure (1260 Infinity III Prime LC) mfr 800 bar
Maximum operating pressure (1260 Infinity III LC) mfr 400 bar
Maximum operating pressure (1220 Infinity II LC) mfr 600 bar
Pressure at 2 mL/min (1290 High-Speed Pump) mfr 1300 bar
Pressure at 5 mL/min (1290 High-Speed Pump) mfr 800 bar
Pressure (1260 Infinity III Flexible Pump) mfr 800 bar
Pressure (1260 Infinity III Binary Pump) mfr 600 bar
Pressure (1260 Infinity III Quaternary Pump VL) mfr 400 bar
Flow rate (1260 Infinity III Quaternary Pump VL) mfr 10 ml/min
Sample capacity (1290 Infinity III Multisampler) mfr 6144 samples
Carryover (1290 Infinity III Multisampler multiwash) mfr 9 ppm
Wavelength range (1290 Infinity III DAD) mfr 190...640 nm
Wavelength range (1260 Infinity III DAD WR) mfr 190...950 nm
ELSD flow range (1290 Infinity III ELSD) mfr 0.2...5 mL/min
RI measurement range (1290 Infinity III RID) mfr 600 RIU
Quick Turn pressure (finger-tight) mfr 600 bar
inline filter pore size (HPLC) mfr 0.5 μm
high-flow heat exchanger volume mfr 3.0 μL
low-dispersion heat exchanger volume mfr 1.1 μL
high flow rate threshold mfr 2.5 mL/min
Electrical, Power & Drive Specifications
Capillary Voltage 3750 V
Mobile phase A mfr 2 Acid
Mobile phase B mfr 0.01 Acid
Mobile phase A (positive mode) mfr 5
Mobile phase B (positive mode) mfr 0.1 ACN
Mobile phase A (negative mode) mfr 0.1 water
Vcap mfr 3500 V
Fragmentor mfr 125 V
Interfaces, Connections & Control
Quick Turn Fitting Pressure Limit 800 bar
Solvent bottle thread mfr 45
Operating Conditions, Environment & Protection
Autosampler Temperature 5 °C
Gas Temperature 300 °C
Sheath Gas Temperature 380 °C
Column thermostat range (1290 Infinity III Multicolumn thermostat) mfr 20...110 °C
Column thermostat range (1260 Infinity III Multicolumn thermostat) mfr 10...85 °C
Standards, Safety & General Data
Analysis time (standard configuration) mfr 7.35 min

Description

Construction and series positioning

Behavior under load and in different modes

Installation, connection and operation

Integration & Operating Notes

Process Limits
Do not exceed 800 bar at Quick Turn fittings

The Quick Turn fitting pressure limit is 800 bar; operating above this risks fitting failure and leakage. Verify that column backpressure at the configured flow rate (1 mL/min) and mobile phase viscosity remains below this limit, especially at low temperatures or with high-viscosity solvents.

Factory Specification Sheet
Process Limits
Column particle size must be 2.7 µm or compatible

The system is specified with 2.7 µm column particles; using larger particles may reduce resolution, while smaller particles can raise backpressure beyond the 800 bar fitting limit. Select columns and flow rates together to stay within the pressure ceiling.

Factory Specification Sheet
Maintenance
PM kit contains 2 pump seals and 4 seal washes

Preventive maintenance kits include 2 pump seals, 2 seal cap assembly sets, 2 gold seals for the outlet valve, and 4 seal washes. Schedule seal replacement according to the PM interval to avoid leaks and baseline noise; the kit is not included in base delivery.

Flyer LC Supplies Recommendations 5994-5755EN
Cooling & Media
Solvent filtration required before use

Use 47 mm, 0.2 µm filter membranes and 10 µm solvent inlet filters to remove particulates; unfiltered mobile phases can clog frits and damage the pump. The filtration assembly includes a 1 L flask and 250 mL funnel.

Flyer LC Supplies Recommendations 5994-5755EN

Selection & Integration Q&A

When should I choose the 1290 Infinity II high-throughput system instead of the 1220 Infinity II LC or the 1260 amino acid analysis system?

Choose the 1290 high-throughput system when method speed and sub-3 µm column performance are critical: it supports 2.7 µm particles and 800 bar fittings, with analysis times of 7.35 min (standard) or 5.1 min (ACR). The 1220 Infinity II LC is a lower-pressure analytical system; the 1260 amino acid system is dedicated to amino acid analysis.

What are the requirements for the LC column and fittings when integrating this system with a mass spectrometer?

Use Quick Turn fittings rated to 800 bar and columns with 2.7 µm particles, such as Poroshell 120 EC-C18 (2.1 × 10 mm) for ACR. The system has been demonstrated with a 6470 TQ MS; ensure the column backpressure at 1 mL/min stays below 800 bar and that the 0.17 mm capillary connects properly.

What maintenance parts and consumables are needed, and are they included in the base delivery?

Preventive maintenance kits (2 pump seals, 2 seal cap assembly sets, 2 gold seals, 4 seal washes), PTFE frits (5 pk), solvent inlet filters (10 µm), and filter membranes (47 mm, 0.2 µm) are not included in base delivery. Order them separately; PM cost reduction is stated as 30%.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Agilent Infinity III LC Series Brochure
Brochure ·7,7 МБ ·36 pp.
View PDF
PDF
Top Supplies to Optimize Your LC Workflow
Brochure ·1,1 МБ ·7 pp.
View PDF