Agilent Technologies 6230C LC/MS TOF
Agilent Technologies 6230C LC/MS TOF — Liquid chromatography mass spectrometry lc ms with Pumping speed 3×10⁻⁵ m³/h.
The Agilent 6230C is an accurate-mass time-of-flight LC/MS system with a Dual Agilent Jet Stream ion source, covering 800–8,000 m/z at 1.0 spectra/s. It is configured for full-spectrum acquisition with internal reference mass correction, achieving a 1.0 ng/mL detection limit. Its primary purpose is accurate-mass screening and confirmation in LC/MS workflows.
Full specifications
| Detection limit | 1.0 ng/mL |
| Pumping speed | 0.5 mL/min |
| Gas Flow | 13 L/min |
| Ion source | Dual Agilent Jet Stream |
| Nebulizer Gas Pressure | 40 psi |
| Post Time | 1.0 minutes |
| Run Time | 20.0 minutes |
| Sample volume | 2 µL |
| Scan speed | 1.0 spectra/sec |
| Sheath Gas Flow | 12 L/min |
| LC/MS system mfr | Accurate-Mass TOF LC/MS LC/MS |
| UHPLC column mfr | 3 μm |
| Stop time mfr | 12.5 minutes |
| Scan range (MS-mode) mfr | 50...1,000 amu |
| Scan rate (MS-mode) mfr | 1.5 spectra/s |
| Scan range (All Ions MS/MS mode) mfr | 50...1,000 amu |
| Scan rate (All Ions MS/MS mode) mfr | 3 spectra/s |
| Internal reference mfr | 921 |
| Sample preparation mfr | 90 |
| Column mfr | 2.1 |
| Linear regression coefficient mfr | 0.999 |
| Calibration range mfr | 10...1,000 μg/mL |
| THC concentration in hemp products mfr | 0.3 |
| Mass range | 800...8,000 m/z |
| Ref mass enabled mfr | Yes Yes |
| Capillary Voltage | 4000 V |
| Nozzle Voltage | 2000 V |
| VCap mfr | 4000 V |
| Fragmentor mfr | 175 V |
| Skimmer mfr | 65 V |
| Mobile phase A mfr | 10 water |
| Mobile phase B mfr | 0.05 acetonitrile |
| Gas Temperature | 325 °C |
| Sheath Gas Temperature | 350 °C |
Description
Construction and positioning
- The 6230C is a time-of-flight (TOF) LC/MS system built around a Dual Agilent Jet Stream ion source, with capillary voltage 4000 V and nozzle voltage 2000 V.
- No sibling models are listed in the verified facts, so positioning within the series cannot be stated beyond this model's own configuration.
Behavior under load and in different modes
- The system supports a mass range of 800–8,000 m/z and a scan speed of 1.0 spectra/s.
- Ion-source operating conditions include sheath gas at 12 L/min and 350 °C, drying gas at 13 L/min and 325 °C, and nebulizer gas pressure at 40 psi.
- A detection limit of 1.0 ng/mL is specified; no curve points are available to describe response behavior further.
Installation, connection and operation
- No PDF digests are available, so installation, connection, control and operation specifics cannot be detailed from verified facts.
- The listed LC parameters (0.5 mL/min pumping speed, 2 µL sample volume, 20.0 min run time, 1.0 min post time) describe an example method rather than instrument limits.
Integration & Operating Notes
Sheath gas flow and temperature (12 L/min, 350 °C), drying gas flow and temperature (13 L/min, 325 °C), and nebulizer pressure (40 psi) are the verified source conditions. Deviating from these setpoints changes desolvation and ion transmission, so they should be treated as method conditions rather than adjustable margins.
Capillary voltage is 4000 V and nozzle voltage is 2000 V in the verified configuration. These potentials define the electrospray regime and must be reproduced in the method; no alternative voltage settings are documented in the verified facts.
Acquisitions must be planned within the stated 800–8,000 m/z range. Ions outside this window are not covered by the verified specification, so method scan ranges and target masses should be checked against this bound before committing to a workflow.
Selection & Integration Q&A
The verified facts list no sibling models, so a direct comparison cannot be made. Choose the 6230C when the required workflow needs accurate-mass TOF acquisition over 800–8,000 m/z at 1.0 spectra/s with a 1.0 ng/mL detection limit and the Dual Agilent Jet Stream source.
The verified method uses 0.5 mL/min pumping speed, 2 µL sample volume, 20.0 min run time and 1.0 min post time. The LC deliverable must sustain these flows and injection volumes; no other column or mobile-phase requirements are stated in the verified facts.
The site must supply nebulizer gas at 40 psi and support sheath gas at 12 L/min and 350 °C plus drying gas at 13 L/min and 325 °C. Gas capacity and purity must be confirmed against these flows before installation; no further utility requirements are documented.
No maintenance intervals, service procedures or accessory lists are present in the verified facts or document digests. Consumables and cables cannot be specified from the available data; these must be obtained from the manufacturer's manual, which was not supplied for this card.