No photo available yet
Agilent Technologies HT NGS sample prep workstation, HT NGS sample prep robot, Bravo
Agilent Technologies HT NGS sample prep workstation, HT NGS sample prep robot, Bravo — Automated liquid handling.
The Bravo NGS workstation is an automated liquid-handling platform configured for high-throughput next-generation sequencing sample preparation, specifically Option B and Option B+ protocols for Avida DNA and SureSelect XT HS2 DNA kits. It processes cfDNA inputs of 1–100 ng and gDNA inputs of 10–100 ng, targeting 150–300 bp insert sizes with 1.96 Mb target and 3.43 Mb probe sizes. This modification is distinguished within the series by its on-deck thermal cycler (ODTC) capability in the B+ configuration, enabling integrated library prep and target enrichment.
Agilent Technologies Automated Liquid Handling Applications Series — Model Comparison & Selection
| Model | Software | Storage temperature, °C | Application | Consumables | Pipetting volume, microliter | Size, mm |
|---|---|---|---|---|---|---|
| HT NGS sample prep workstation, HT NGS sample prep robot, Bravo Current | — | 20 | — | — | — | — |
| Metabolomics Sample Prep Automation, Plasma Sample Prep Robots | Agilent Bravo Metabolomi | — | extracting metabolites i | 96 | wide | hood-friendly |
Full specifications
| Input quantity (cfDNA) mfr | 1...100 ng |
| Input quantity (gDNA) mfr | 10...100 ng |
| Fragmentation insert size mfr | 150...300 bp |
| Target size mfr | 1.96 Mb |
| Probes size mfr | 3.43 Mb |
| Storage temperature | 20 °C |
Description
Construction and series positioning
- The Bravo NGS workstation is a benchtop automated liquid handler built around a multichannel pipetting head and a deck that accepts labware for reagent, sample, and tip storage.
- Within the Agilent automated liquid handling series, this model is the NGS sample-prep configuration (Option B / B+), distinct from sibling configurations for metabolomics, plasma sample prep, and NGS enrichment/library prep.
- Option B+ adds an on-deck thermal cycler (ODTC), allowing thermal cycling steps to occur without manual transfer; Option B lacks the ODTC and is used where thermal cycling is performed off-deck.
- The workstation is qualified for use with Avida DNA reagent kits (96 reactions) and SureSelect XT HS2 DNA kits, including MBC, Hyb time, and pooling options.
Process behavior and media
- Input quantity ranges are protocol-defined: 1–100 ng for cfDNA and 10–100 ng for gDNA, with fragmentation insert sizes of 150–300 bp.
- Target size is 1.96 Mb and probe size is 3.43 Mb for the referenced capture panels (Discovery, Expanded, Focused, Onco LB, Onco LB Plus, Lymphoma, and Custom AddOn).
- Storage temperature is specified at 20 °C; no other environmental or electrical ratings are provided in the verified facts.
- No digitized curve points are available; performance is defined by the protocol guides rather than by a published liquid-handling curve.
Installation, control, and operation
- Operation is driven by VWorks Form for Option B (Version A2, October 2023) and protocol versions C0–C2 and B0 for Avida DNA; the B+ configuration uses the SureSelect XT HS2 DNA protocol with ODTC.
- The workstation is integrated with Illumina paired-end multiplexed sequencing workflows; an appendix covers FFPE-derived DNA samples.
- No electrical, interface, or compliance specifications are listed in the verified facts; these must be obtained from the site-preparation or user manual before installation.
Integration & Operating Notes
The Avida DNA and SureSelect XT HS2 protocols define separate input ranges: 1–100 ng for cfDNA and 10–100 ng for gDNA. Loading outside these windows invalidates the library prep assumptions and may require a different protocol version or kit configuration.
On the B+ configuration, the on-deck thermal cycler (ODTC) executes thermal cycling steps within the VWorks protocol. The run sequence must allocate ODTC time correctly; Option B protocols without ODTC require off-deck cycling and manual transfer between steps.
Avida DNA protocols are issued as versions C0–C2 and B0, and SureSelect XT HS2 uses VWorks Form Version A2 (October 2023). Using a mismatched form or protocol version with a given reagent kit can produce incorrect reagent volumes and failed libraries; verify version against the kit before each run.
Selection & Integration Q&A
Choose this configuration when the workflow is NGS library prep and target enrichment with Avida DNA or SureSelect XT HS2 kits, especially if on-deck thermal cycling is needed (Option B+). Sibling metabolomics and plasma configurations are for different sample matrices and assays, not for NGS library construction.
The workstation requires the matching reagent kits (Avida DNA G9418A/G9418B, 96 reactions, or SureSelect XT HS2 DNA kits), the appropriate capture probe panel, VWorks Form Version A2 for Option B, and Illumina paired-end sequencing downstream. Labware and tips must be qualified for the Bravo deck; no electrical or interface ratings are given in the verified facts.
Protocol versions C0–C2 and B0 (Avida DNA) and VWorks Form A2 (SureSelect XT HS2) must be verified against each kit lot before runs. Reagent kits, capture panels, labware, tips, and the ODTC (Option B+ only) are separate items; the verified facts do not list a maintenance interval or included accessories.