Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Cary 635 FTIR Spectrometer—Compact, Benchtop FTIR

Agilent Technologies Cary 635 FTIR Spectrometer—Compact, Benchtop FTIR — Molecular spectroscopy.

Benchtop FTIR spectrometer with a 25 mm optical aperture and interchangeable sampling modules, including single-reflection ZnSe and Ge ATR, multireflection ZnSe ATR, DialPath and TumblIR. The Cary 635 covers 5100–600 cm⁻¹ and accepts 20 µL sample volumes; its ATR path length is 2.6 µm with a 2.5 mm surface diameter. It is used for quantitative polymer additive analysis and blend-ratio determination in QA/QC laboratories.

Full specifications

Core Performance & Functional Specifications
Wavelength range 5100...600
Atr Surface Diameter 2.5 mm
Diamond Atr Active Area 200 µm
Diamond Atr Sampling Surface Diameter 1 mm
Dimensions 16 centimeters
Effective Pathlength 2.6 μm
Firmware Load Time 15 seconds
Ge Atr Effective Pathlength 0.15 µm
Optical Aperture 25 mm
Sample volume 20 µL
Warmup Period 5 minutes
Znse Atr Active Area 200 µm
Znse Atr Sampling Surface Diameter 1 mm
Bench space required mfr 20 cm
ATR spectral range mfr 5100...600
Analyzed additive concentration (Irganox 1010 in polyethylene) mfr 0.16 wt%
Dimensions (main optical unit) mfr 16 cm
Warmup period before reliable analysis mfr 5 minutes
Warmup before performance validation tests mfr 120 minutes
Energy (center-burst) diagnostic, optimal mfr 28000
Energy (center-burst) diagnostic, marginal mfr 28000
Energy (center-burst) diagnostic, critical mfr 30000
Laser signal diagnostic, optimal mfr 15000
Laser signal diagnostic, marginal mfr 15000
Laser signal diagnostic, critical mfr 17000
Diamond ATR window thickness mfr 0.5 mm
ZnSe ATR window thickness mfr 0.5 mm
Germanium ATR effective pathlength at 1,700 cm-1 mfr 0.36 μm
Germanium ATR effective pathlength at 600 cm-1 mfr 1.02 μm
Performance test resolution mfr 4
Performance test collection time mfr one minute minute
Performance test duration mfr two minutes per test minutes minutes
Minimum number of performance tests mfr 15 tests
Performance test spectral regions mfr 2600
Stability test spectral regions mfr 3000
Main optical unit dimensions mfr 6.2 in
Validation warmup period mfr 120 minutes
Energy (center-burst) optimal mfr 28000
Energy (center-burst) marginal mfr 28000
Energy (center-burst) critical mfr 30000
Laser signal optimal mfr 15000
Laser signal marginal mfr 15000
Laser signal critical mfr 17000
Unpacking mfr 11
Installation mfr 12
Components mfr 13
Connecting power mfr 13
Power cord selection mfr 14
MicroLab software mfr 16
Turning On the Instrument mfr 16
Turning Off mfr 17
Performance Verification mfr 17
G8043-67483 mfr Replacement flat tip for ATR ATR
G8043-67484 mfr Replacement pellet tip for ATR ATR
G8043-67405 mfr Polystyrene film for ATR/Transmission sampling a
G8043-67406 mfr Polystyrene film for TumblIR/DialPath sampling a
PIKE-162-5450 mfr 38 μm
G8043-67400 mfr Infrared source with purge fitting fitting
G8043-67401 mfr Desiccant with purge fitting fitting
G8043-67402 mfr KBr window with removal tool tool
G8043-67403 mfr ZnSe window with removal tool tool
G8043-67003 mfr Cary FTIR Swivel Diamond ATR Press Press
G8043-67004 mfr Cary FTIR Swivel Ge-ZnSe Press Press
G8043-67012 mfr Purge kit for engine and Transmission sampling a
G8043-67524 mfr Cary FTIR Base Plate Rubber Bumper+Screw Screw
G8043-67407 mfr 635 Supply
G8043-67408 mfr 635 Cable
System OFF mfr Red Red
System startup mfr Red / green green
System ON mfr Green Green
Firmware update mfr Red / green green
Validation warmup mfr 120 minutes
ATR window thickness mfr 0.5 mm
Post-maintenance equilibration time mfr 30 hours
Dimensions, Weight & Mechanical Design
Atr Path Length 2.6 μm
Diamond Atr Depth Of Penetration 2 µm
Weight 3.8 kg
Electrical, Power & Drive Specifications
Source diagnostic, optimal mfr 2.1 A
Source diagnostic, marginal mfr 2.4 A
Source diagnostic, critical mfr 2.7 A
Source current optimal mfr 2.1 A
Source current marginal mfr 2.4 A
Source current critical mfr 2.7 A
Materials, Media & Process Compatibility
ATR effective pH range mfr 1...14
ZnSe ATR pH range mfr 5...9
Operating Conditions, Environment & Protection
Environment mfr 15
Desiccant replacement humidity mfr 30

Description

Construction and series positioning

The Cary 635 is a benchtop FTIR engine built around a 25 mm optical aperture and a modular sampling interface. Unlike the handheld 4200 FlexScan, 4300 and 4500 models, it is a laboratory instrument requiring 20 cm of bench space and weighing 3.8 kg. Within the Cary 635 line, the base engine is configured by selecting one of the interchangeable sampling modules: single-reflection ZnSe ATR, single-reflection Ge ATR, multireflection ZnSe ATR, DialPath, TumblIR, diffuse reflectance, 45° or 10° specular reflectance, or transmission.

Sampling behavior and media

Installation and operation

Bench space of 20 cm is required. Sampling modules are exchanged at the instrument interface; no ordering codes or size variants are printed in the brochures. The application brochure pairs the Cary 635 with DialPath and TumblIR accessories and MicroLab software for PE/PP additive and copolymer blend-ratio analysis. No electrical, control or I/O specifications are given in the supplied documents.

Integration & Operating Notes

Process Limits
ATR crystal pH must stay within 5–9

Samples outside the stated ATR effective pH range of 5 to 9 can chemically attack the ZnSe or Ge crystal, degrading the 2.6 µm path length and the 2.5 mm surface. Neutralize or dilute aggressive samples before measurement, or select a different sampling module.

Factory Specification Sheet
Process Limits
Minimum 20 µL sample volume for reliable spectra

The ATR and transmission modules require at least 20 µL to fully cover the 2.5 mm ATR surface. Underfilling produces poor contact and non-reproducible absorbance, especially for the 0.16 wt% additive-level measurements described in the application brochure.

Factory Specification Sheet; Brochure Applications of FTIR 5994-2009EN
Maintenance
Inspect and clean ATR crystal after each sample set

Residue on the 2.5 mm ATR surface changes the effective path length and can scratch the ZnSe or Ge crystal. Clean the crystal with a solvent compatible with the pH 5–9 window after each sample set, and verify the background spectrum before quantitative runs.

Brochure Cary 635 FTIR 5994-9110EN

Selection & Integration Q&A

When should I choose the Cary 635 benchtop FTIR instead of the 4200 FlexScan or 4300 handheld models?

Choose the Cary 635 when 20 µL sample volumes, a 25 mm aperture and interchangeable ATR/DialPath/TumblIR modules are needed for quantitative polymer additive analysis in a fixed laboratory. The handheld 4200/4300 models suit field identification where bench space and module exchange are not available.

What sampling accessories and software are required to run the 0.16 wt% Irganox 1010 polyethylene analysis?

The application brochure uses the Cary 635 with DialPath or TumblIR sampling accessories and MicroLab software. The base engine alone does not include these modules; they must be specified separately to reproduce the 0.16 wt% additive determination.

What maintenance and consumables are not included with the base Cary 635 delivery?

The base engine ships without sampling modules; ZnSe/Ge ATR, DialPath and TumblIR accessories and MicroLab software are separate items. Routine maintenance includes cleaning the 2.5 mm ATR crystal within the pH 5–9 window; no service interval is printed in the supplied brochures.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
User's Guide
Manual ·66 pp.
View PDF