Agilent Technologies Electrospray ion Source, ESI
Agilent Technologies Electrospray ion Source, ESI — Liquid chromatography mass spectrometry lc ms with Pumping speed 2.4×10⁻⁵ m³/h.
The electrospray-esi-source is an ESI ion source configuration for Agilent LC/MS systems, specified here in positive ion mode with a 5000 V capillary, 14 L/min drying gas at 290 °C, and 12 L/min sheath gas at 400 °C. It operates at 0.4 mL/min pumping speed with a 20 psi nebulizer and 2000 V nozzle, intended to ionize LC eluent for MS detection.
Agilent Technologies LC MS Ion Sources Series — Model Comparison & Selection
| Model | Pumping speed, m³/h | Sample volume, milliliter | Column temperature, °C | Drying gas temperature, °C | Sheath gas flow, liter/minute | Sheath gas temperature, °C |
|---|---|---|---|---|---|---|
| Electrospray ion Source, ESI Current | 2.4×10⁻⁵ | 0.001 | 80 | 290 | 12 | 400 |
| Atmospheric Pressure Chemical Ionization Source, APCI | 2.4×10⁻⁵ | 0.004 | 55 | 350 | — | — |
| High sensitivity MS, high sensitivity ion source, Jet Stream | — | — | — | — | 0.011 | 350 |
Full specifications
| Pumping speed | 0.4 mL/min |
| Column temperature | 80 °C |
| Drying Gas Flow | 14 L/min |
| Sample volume | 1 µL |
| Sheath Gas Flow | 12 L/min |
| Stop time mfr | 7 minutes |
| Ion mode mfr | Positive ion mode, ESI ESI |
| Nebulizer mfr | 20 psi |
| Sample concentration mfr | 100 μg/mL |
| Capillary Voltage | 5000 V |
| Mobile phase A mfr | 0.1 water |
| Mobile phase B mfr | 90 acid |
| Nozzle mfr | 2000 V |
| Drying Gas Temperature | 290 °C |
| Sheath Gas Temperature | 400 °C |
| Sample thermostat mfr | 5 °C |
Description
Construction and positioning
- This is an electrospray ionization (ESI) source, not a complete LC/MS instrument; it is the atmospheric-pressure ionization interface between an LC column and the mass spectrometer.
- Within the Agilent LC/MS series, it is the ESI source modification, distinct from the sibling instruments (6230 TOF, 6475/6495 triple quadrupole, 6530 Q-TOF), which are full mass spectrometers that may use such a source.
- The verified configuration is positive ion mode ESI with a 5000 V capillary voltage and a 2000 V nozzle voltage.
Behavior under operating conditions
- Drying gas is specified at 14 L/min and 290 °C; sheath gas at 12 L/min and 400 °C, supporting desolvation at the stated 0.4 mL/min pumping speed.
- Nebulizer pressure is 20 psi; sample volume 1 µL at 100 µg/mL sample concentration.
- Column temperature 80 °C, column 300 µm, sample thermostat 5 °C; mobile phase A 0.1 (water), B 90 (acid), stop time 7 minutes.
Installation and control
- The attached application note (5991 2116EN) describes use with an Agilent 6550 iFunnel Q-TOF with Agilent JetStream coupled to a 1290 Infinity LC System, but provides no installation, connection, or control specifics for this source; those details are not available in the verified facts.
Integration & Operating Notes
The source is specified at 5000 V capillary and 2000 V nozzle in positive ion mode. These high voltages require the MS interlock chain to be intact; the verified facts do not include interlock logic, so the engineer must confirm startup and shutdown sequencing against the instrument manual.
Selection & Integration Q&A
This item is the ESI ion source itself, not a complete spectrometer. Choose it when you already have an Agilent LC/MS and need the electrospray interface; choose a sibling (6230 TOF, 6475/6495 QQQ, 6530 Q-TOF) when you need the full mass analyzer with its own detection limits and mass range.
It is specified for 0.4 mL/min LC flow, 20 psi nebulizer, 14 L/min drying gas at 290 °C, 12 L/min sheath gas at 400 °C, 5000 V capillary and 2000 V nozzle in positive ESI. The LC, gas supplies, and MS must support these setpoints; the verified facts do not list fitting sizes or controller interfaces.
The verified facts contain no mounting dimensions, ambient temperature range, or duty-cycle rating for the source. The only environmental setpoints given are the gas temperatures (290 °C drying, 400 °C sheath) and column/sample thermostat values (80 °C, 5 °C); installation limits must be confirmed from the instrument manual.
No maintenance interval, error-code list, cable, or consumable is specified in the verified facts. The attached document 5991 2116EN is an application note for intact protein analysis on a 6550 iFunnel Q-TOF with JetStream and a 1290 Infinity LC, not an ordering datasheet, so accessories and service parts must be confirmed separately.