Agilent Technologies Pulsed-field CE technology, Femto Pulse system
Agilent Technologies Pulsed-field CE technology, Femto Pulse system — Automated electrophoresis.
The Femto Pulse System is an automated pulsed-field capillary electrophoresis instrument built on the Fragment Analyzer platform, configured with a pulsed-field power supply and a 12-capillary array. It resolves DNA fragments up to 165 kb and quantifies inputs down to 50 fg/µL with ultra-sensitivity kits, separating 165 kb fragments in 1.5 hours. It serves as a QC station for HMW gDNA and long-read sequencing libraries, replacing manual PFGE with faster, quantitative sizing.
Full specifications
| Analysis time | 30 minutes |
| Average Smear Size (final Library) | 7.7 kb |
| Centrifugation Speed | 7600 rpm |
| Maximum Separable Dna Fragment Size | 165000 bp |
| Maximum Separable Genomic Dna Size | 165000 bp |
| Minimum Dna Fragment Input Concentration (ultra Sensitivity Kits) | 50 fg/µL |
| Sample Amount | Picograms |
| Sample Volume Per Well | 2 µL |
| Separation Time For 165,000 Bp Fragments | 1.5 hours |
| Size-selection Cutoff (example, Blue Pippin) | 8 kb |
| Smear Analysis Upper Limit | 165 kb |
| Samples per run mfr | 1...14 samples |
| Total time (incl. gel prep., separation, and staining) mfr | 12...26 hours |
| Size range mfr | 10 Mb |
| Result format mfr | Agarose gel image; requires manual annotation an |
| BAC insert size range mfr | 100...300 kb |
| Parallel sample capacity mfr | 12 samples |
| Maximum fragment size resolved mfr | 165 kb |
| Sizing range mfr | 1.3...165 kb |
| Quantification accuracy mfr | 20 |
| Quantification precision mfr | 25 %CV |
| Electrophoresis method mfr | Pulsed field field |
| Sizing precision (final library) mfr | 6 less |
| Recommended input gDNA GQN threshold mfr | 7.0 higher |
| Recommended gDNA shearing size mfr | 10...25 kb |
| Maximum DNA sizing range mfr | 165 kb |
| Size-selection cutoff method mfr | 40 kb |
| Sample shearing device mfr | g-TUBE TUBE |
| Mean read quality mfr | 11.0 |
| Median read quality mfr | 11.2 |
| Number of reads mfr | 58413 |
| Total bases mfr | 973 millions |
| Sizing precision, final library mfr | 6 less |
| gDNA shearing target size mfr | 10...25 kb |
| Smear analysis lower limit mfr | 400 bp |
| Speed advantage vs pulsed-field gel electrophoresis (PFGE) mfr | 10 faster |
| Input concentration range (fragments) mfr | 0.1 pg/μL |
| Input concentration range (smears) mfr | 25 pg/μL |
| Kit size mfr | 275 samples |
| Input concentration range (total RNA) mfr | 15 pg/μL |
| Input concentration range (mRNA) mfr | 25 pg/μL |
| Input concentration range (fragment up to 48 kb) mfr | 3 pg/μL |
| Input concentration range (fragment <2 kb) mfr | 1 pg/μL |
| Input concentration range (fragment <48 kb) mfr | 1.6 pg/μL |
| Input concentration range (fragment >48 kb) mfr | 3 pg/μL |
| Input concentration range (multiple frags) mfr | 12.5 pg/μL |
| Sizing precision mfr | 20 %CV |
| Recommended GQN threshold (input gDNA) mfr | 7.0 |
| Target sheared gDNA size mfr | 10...25 kb |
| Ladder upper size (gDNA ScreenTape) mfr | 48.5 kb |
| Sizing accuracy mfr | 15 |
| Number of reads above Q7 mfr | 58409 |
| Number of reads above Q10 mfr | 47903 |
| Number of reads above Q12 mfr | 11682 |
| Number of reads above Q15 mfr | 5 |
| Speed advantage versus PFGE mfr | 10 faster |
| Sample dilution mfr | single dilution dilution |
| Capillary arrays mfr | 12 arrays |
| n–1 resolution mfr | 60 nt |
| Samples separated per run mfr | 12 samples |
| Samples per Run mfr | 1...14 |
| Total Time (Inc. Gel Prep., Separation, and Staining) mfr | 12...26 hours |
| Size Range mfr | 10 Mb |
| Result Format mfr | Agarose gel image; requires manual annotation an |
| Digestion reaction volume mfr | 20 μL |
| Sample dilution factor mfr | 10 X |
| Diluent Marker volume mfr | 18 μL |
| PFGE separation time mfr | 10.5 hours |
| PFGE agarose gel concentration mfr | 1 |
| PFGE loaded sample volume mfr | 20 μL |
| UV exposure wavelength mfr | 365 nm |
| Kit name mfr | 165 kit |
| Sample concentration range mfr | 0.3...30 pg/μL |
| Femto Pulse run time mfr | 1.5 hours |
| Femto Pulse sizing range mfr | 165 kb |
| Fragment Analyzer run time mfr | 70 less |
| TapeStation sample capacity mfr | 96 samples |
| Femto Pulse loading concentration mfr | 300 pg/μL |
| Fragment Analyzer loading concentration mfr | 1 ng/μL |
| TapeStation loading concentration mfr | 30 ng/μL |
| Femto Pulse gDNA smear lower limit mfr | 400 bp |
| Femto Pulse ladder last fragment mfr | 165 kb |
| Fragment Analyzer ladder last fragment mfr | 48.5 kb |
| TapeStation gDNA ladder upper limit mfr | 48.5 kb |
| TapeStation smear extrapolation limit mfr | 60 kb |
| PacBio HiFi WGS shear target mfr | 10...25 kb |
| needle gauge mfr | 25 gauge |
| shear sample volume (needle) mfr | 50 μL |
| shear sample concentration (needle) mfr | 150 ng/μL |
| g-TUBE sample volume mfr | 150 μL |
| g-TUBE sample concentration mfr | 100 ng/μL |
| DNA input for library mfr | 500 ng |
| sizing range mfr | 165 kb |
| speed advantage vs PFGE mfr | 10 faster |
| maximum queued samples mfr | 288 samples |
| number of gel types mfr | two gel types types |
| sample separation time mfr | 30 minutes |
| samples per run mfr | 12 samples |
| capillary array options mfr | 12 arrays |
| resolution range mfr | 60 nt |
| Median Read Length | 8587 bp |
| Read Length N50 | 12152 bp |
| Mean read length mfr | 36259.8 bp |
| Average read length mfr | 7.2 kb |
| E. coli library mean HiFi read length mfr | 19.0 kb |
| Human library mean HiFi read length mfr | 7.2 kb |
| Maximum Extended Warranty | 5 years |
| Standard Warranty | 1 year |
| Maximum extended warranty time mfr | five years total total |
| standard warranty period mfr | one-year year |
Description
Construction and series positioning
- The Femto Pulse is a dedicated configuration of the Fragment Analyzer platform: the same automated capillary electrophoresis architecture, but fitted with a pulsed-field power supply and a 12-capillary array to extend the resolvable size range to 165 kb.
- It is the high-molecular-weight member of Agilent's automated electrophoresis portfolio; the 5200/5300/5400 Fragment Analyzer systems and 4150/4200 TapeStation systems cover lower size ranges, while the Femto Pulse is specified for fragments and genomic DNA up to 165 kb.
- The instrument is supplied with ProSize data analysis software; consumables are quantitative kits (gDNA 165 kb, Ultra Sensitivity NGS, Ultra Sensitivity RNA) and qualitative kits (55 kb BAC, 165 kb BAC), all in 275-sample kit sizes, plus the Femto Pulse 12-Capillary Array.
Behavior and performance envelope
- Separation of 165 kb fragments takes 1.5 hours; the broader separation window is 10–24 hours, and total time including gel preparation, separation, and staining is 12–26 hours.
- Sizing range extends down to 75 bp and up to 165 kb; smear analysis covers 400 bp to 165 kb. Quantification accuracy is 20 and precision is 15 %CV.
- Ultra-sensitivity NGS kits lower the minimum DNA input concentration to 50 fg/µL, enabling library QC from picogram-level samples.
- For long-read workflows, the system supports gDNA shearing targets of 10–25 kb (g-TUBE) and size-selection cutoffs (e.g., Blue Pippin at 8 kb); reported mean read length in the application note is 36,259.8 bp with mean read quality 10.8 and median 11.0.
- The system is cited as 10× faster than pulsed-field gel electrophoresis (PFGE) for BAC analysis, with a 100–300 kb BAC insert size range.
Installation, control, and operation
- The instrument is controlled through the platform software with ProSize for data analysis; results are presented as agarose gel images that require manual annotation and documentation.
- Sample volume per well is 2 µL; parallel sample capacity is 12 capillaries, with 1–14 samples per run depending on kit and array configuration.
- The pulsed-field power supply is integral to the instrument; no external high-voltage supply is described in the source documents.
- Standard warranty is one year, upgradeable to CrossLab Silver for up to five years total.
Integration & Operating Notes
The recommended input genomic DNA GQN threshold is 7.0; below this, sizing and quantification results for HMW libraries are not reliable. Verify GQN before shearing to 10–25 kb, since degraded starting material will not yield the 165 kb upper-range performance the instrument is specified for.
The recommended gDNA shearing size is 10–25 kb using the g-TUBE device. Loading unsheared high-molecular-weight gDNA outside this window can exceed the sizing range or produce smears that are difficult to annotate; the 165 kb upper limit applies to resolved fragments, not to arbitrary input size distributions.
The Femto Pulse 12-Capillary Array is a consumable supplied separately from the instrument; kits are provided in 275-sample kit sizes. Plan array replacement and kit consumption together, because the capillary array is not part of the base instrument delivery and its condition directly affects sizing precision (6% CV for final libraries).
Output is an agarose gel image processed by ProSize software; the system does not automatically annotate or archive results. Integrate a documentation step into the workflow so that sizing and smear calls are traceable, especially when the instrument is used as a QC gate before sequencing.
The pulsed-field capability is built into the instrument configuration; there is no separate external pulsed-field supply to site or connect. Electrical ratings are not stated in the supplied documents, so confirm facility requirements against the instrument's site preparation guide before installation.
Selection & Integration Q&A
Choose the Femto Pulse when fragments or gDNA exceed the sizing range of the 5200/5300/5400 Fragment Analyzer or 4150/4200 TapeStation systems: it resolves up to 165 kb and performs smear analysis from 400 bp to 165 kb. For routine NGS libraries below ~50 kb, the Fragment Analyzer or TapeStation is sufficient and the Femto Pulse's 10–24 h separation window is unnecessary.
The base instrument does not include the 12-Capillary Array or analysis kits. Order the Femto Pulse 12-Capillary Array plus the appropriate kit: quantitative gDNA 165 kb, Ultra Sensitivity NGS, or Ultra Sensitivity RNA, or qualitative 55 kb BAC or 165 kb BAC kits, all in 275-sample sizes. ProSize software is part of the platform; CrossLab Silver service is an optional warranty upgrade.
Input gDNA should have a GQN of at least 7.0 and be sheared to 10–25 kb with the g-TUBE device. Load 2 µL per well; ultra-sensitivity NGS kits accept down to 50 fg/µL. For BAC analysis, the 165 kb BAC kit covers 100–300 kb inserts. Size selection upstream (e.g., Blue Pippin at 8 kb cutoff) should be completed before the run.
Dimensional Drawings & Technical Documentation
Dimensional drawings
Click drawing to inspect vector dimensions