No photo available yet

Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Upgrade kits for HPLC injector improve functionality

Agilent Technologies Upgrade kits for HPLC injector improve functionality — Liquid chromatography.

The 1260 Infinity II GPC/SEC System is a high-performance liquid chromatography platform for gel permeation and size-exclusion separations. This injector-upgrade configuration is defined by its electrical interface: 100 V AC input at 50 Hz, 3 A input current, 200 W nominal power, and a 36 V DC / 5.55 A output stage. It is intended for integration into a complete GPC/SEC workflow where the injector module is specified separately from the base LC system.

Agilent Technologies HPLC Uhplc Upgrades Series — Model Comparison & Selection

Model Pumping speed, m³/hColumn particle size, µmDepth, mmFilter membrane pore size, µmFlow cell path length, mmFrequency, Hz
Upgrade kits for HPLC injector improve functionality Current ——795——50
Infinity III LC upgrades | Upgrade existing HPLC/UHPLC systems 3×10⁻⁵1.8—0.2210—

Full specifications

Core Performance & Functional Specifications
Nominal power 200 W
Nominal power 200 W
Dimensions, Weight & Mechanical Design
Depth 795 mm
Height 770 mm
Weight 18.79 kg
Width 1270 mm
Electrical, Power & Drive Specifications
Frequency 50 Hz
Input Current 3 A
Output current 5.55 A
Output voltage 36 V
Input voltage mfr 100 AC
Input line voltage mfr 100 V
Operating Conditions, Environment & Protection
Operating Altitude 3000 m
Operating humidity range mfr 95 condensing

Description

Construction and positioning

Electrical behavior

Installation and operation

Integration & Operating Notes

Electrical
Match supply to 100 V AC / 50 Hz input, not to the 36 V DC output

The configuration is rated for a 100 V AC, 50 Hz line with 3 A input current and 200 W nominal power. The 36 V DC / 5.55 A figures belong to the internal output stage and must not be used to size the facility supply. Confirm the site provides 100 V AC at 50 Hz before installation.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose this injector-upgrade configuration instead of a complete 1220 Infinity II LC System or a 1260 purification system?

Pick this configuration when the GPC/SEC separation hardware is already specified and only the injector layer is being upgraded within the 1260 Infinity II series. Choose the 1220 Infinity II LC System for a complete analytical LC, or the 1260 Analytical-Scale LC Purification System when purification duty is the target.

What supply and adjacent hardware must be in place before this configuration can be powered and connected?

A 100 V AC, 50 Hz line rated for 3 A and 200 W nominal is required; the 36 V DC / 5.55 A output is internal and not a facility supply. Autosampler integration follows the PAL3 RTC 120/160 site-preparation checklists, which cover the G7370B/G7396B modules and tray-cooler hardware.

What is included for installation and what must be ordered or scheduled separately?

The supplied documentation consists of PAL3 site-preparation checklists (D0130828, D0113215) covering autosampler modules and tray-cooler hardware. No cables, consumables, service-interval schedule, or error-code table were included in the supplied digests, so these must be confirmed with the vendor before commissioning.

Dimensional Drawings & Technical Documentation

Technical documentation