No photo available yet

Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Liquid Explosive Detectors, Bottle Liquid Scanners

Agilent Technologies Liquid Explosive Detectors, Bottle Liquid Scanners — Molecular spectroscopy.

Handheld through-barrier Raman identification system using spatially offset Raman spectroscopy (SORS) to detect hazardous materials, explosives, narcotics and NPS behind colored/opaque plastics, glass, paper, card, wrapping and fabrics, including single and multiple barrier layers. Scan times are 5 s for metal containers and 6 s for nonmetal containers, with a 2.5 % false-alarm rate. ECAC type A and B certified and UK DfT approved for containers under 100 mL, it is deployed for field screening of sealed bottles and packages without opening them.

Agilent Technologies Raman Spectroscopy Series — Model Comparison & Selection

Model TechnologyApproval for small containers, mLFalse alarm rate, %Scan time metal containers, secScan time nonmetal containers, sec
Liquid Explosive Detectors, Bottle Liquid Scanners Current spatially offset Raman s1002.556
Raman Analyzers for Pharmaceutical Quality Control spatially offset Raman s1002.556

Full specifications

Core Performance & Functional Specifications
Technology spatially offset Raman spectroscopy
Approval For Small Containers 100 mL
False Alarm Rate 2.5 %
Scan Time, Metal Containers 5 sec
Scan Time, Nonmetal Containers 6 sec
Measurement mode mfr through-barrier identification identification
Barrier types mfr colored and opaque plastics, glass, paper, card,
Barrier layers mfr single and multiple multiple
Target substances mfr hazardous materials, explosives, narcotics, NPS
Library mfr continuously updated with new psychoactive subst
Fluorescence interference mfr reduced reduced
Certification mfr ECAC type A and B B
Detection technology mfr Spatially Offset Raman Spectroscopy Spectroscopy
Deployments mfr 1000
Fentanyl potency relative to heroin mfr 10...1,000 times
Active dose of several NPS types mfr micrograms μg μg
Deployments worldwide mfr 1000
laser wavelength mfr 830 nm
library size (narcotics/NPS/controlled substances) mfr 300
library size (cutting agents) mfr 200
scans per method mfr 10 scans
repeat tests per model mfr three times times
spectral region mfr 1500
approved container volume mfr 100 mL
Dimensions, Weight & Mechanical Design
Form factor mfr handheld handheld

Description

Construction and positioning

Behavior under load / in different modes

Installation, connection, control and operation

Integration & Operating Notes

Maintenance
Substance library must be kept current for NPS coverage

The library is continuously updated with new psychoactive substances. An instrument whose library has not been updated will not identify newly scheduled NPS, so library update status must be part of the routine service schedule rather than a one-time commissioning step.

Factory Specification Sheet
Control & I/O
No control, power or interface data supplied for this model

The verified facts contain no voltage, current, battery, data-interface or control-signal specifications for this handheld unit. Integration planning for power, charging or data export cannot be based on this card and must come from the instrument's own manual.

Factory Specification Sheet

Selection & Integration Q&A

When should this liquid-explosive/bottle-scanner configuration be chosen instead of the sibling Handheld Chemical Detector, Hazmat ID, Resolve or the Raman Analyzers for Pharmaceutical Quality Control?

Pick this modification when the task is screening sealed liquid bottles and packages for explosives, narcotics and NPS with ECAC type A and B certification and UK DfT approval for containers under 100 mL. The Resolve sibling is positioned for hazmat ID, and the pharmaceutical Raman analyzers for raw-material QC; both share SORS but not this certification scope.

What adjacent system parts or accessories must be specified with this handheld unit, and what is not included in base delivery?

The verified facts list no cables, chargers, batteries, docking stations or calibration accessories, and no power or data-interface specifications. Adjacent power, charging and data-export hardware therefore cannot be confirmed from this card and must be taken from the instrument manual and order configuration.

What maintenance and library-service actions are required, and which consumables are outside base delivery?

The substance library is continuously updated with new psychoactive substances, so scheduled library updates are required to retain NPS coverage. No calibration standards, reference samples, batteries or cables are listed as included; the verified facts do not define service intervals beyond the library-update requirement.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Detection of Hazardous Narcotics
Brochure ·1,7 МБ ·4 pp.
View PDF
PDF
Identification of Commercially Sterile Products Using the Vaya
Manual ·770,4 КБ ·7 pp.
View PDF
PDF
How Much Are False Alarms
Brochure ·675,2 КБ ·2 pp.
View PDF