Agilent Technologies AA Spray Chamber & Components | AAS Atomization Chamber
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies AA Spray Chamber & Components | AAS Atomization Chamber

Agilent Technologies AA Spray Chamber & Components | AAS Atomization Chamber — Atomic spectroscopy.

The Agilent spray chamber for atomic absorption is a replacement component for Mark 7 burner/spray chamber assemblies used in Agilent 55/240/280 flame AAS systems. It is supplied as part of a consumable and spare-parts portfolio that also covers hollow cathode lamps, sample-introduction parts, VGA 77 vapor-generation accessories, and SPS 4 autosampler items. Its primary purpose is to complete the sample-introduction path in flame AA, where aerosol conditioning and transport to the burner are required.

Full specifications

Core Performance & Functional Specifications
Burner Cleaning And Alignment Card Pack Size 100 pk
Capillary Tubing Pack Size 3 pk
Glass Impact Beads Pack Size 5 pk
Sample Vial Volume 1.1 mL
Syringe Volume 100 µL
Hydride absorption cells quantity mfr 2
Flowthrough mercury absorption cell quantity mfr 1
AA hydride module quantity mfr 1
PVC peristaltic pump tubing quantity mfr 1 each
Sample rack capacity mfr 16 od
Rack overlay positions mfr 60 positions
Standards rack positions mfr 34 positions
Dimensions, Weight & Mechanical Design
Capillary tubing inner diameter mfr 0.38 ID
SPS 4 probe inner diameter mfr 1.0 id

Description

Construction and series positioning

Behavior and media

Installation, connection, and control

Integration & Operating Notes

Maintenance
Spray chamber is a consumable spare in the Mark 7 flame-AA set

The attached flyer lists Mark 7 burner/spray chamber items among recommended consumable supplies and spare parts for Agilent Flame AAS (55/240/280 AAS). Engineers should treat the spray chamber as a replaceable sample-introduction component and verify the exact Mark 7 assembly variant before ordering, because the digest does not specify interchangeability across the 55, 240, and 280 flame systems.

Flyer: Top Supplies for Flame and Graphite Furnace AAS, 5994-5771EN
Process Limits
No operating limits are published in the supplied digest

The document digest contains no sections or actionable engineering facts, so maximum gas pressure, sample flow, acid concentration, or temperature limits for this spray chamber are not available. Any integration must rely on the instrument's own Mark 7 burner/spray chamber manual rather than this card, and no numeric limit should be assumed from the pack-size specifications.

Flyer: Top Supplies for Flame and Graphite Furnace AAS, 5994-5771EN

Selection & Integration Q&A

When should I choose this spray chamber rather than a sibling AA model such as the 240FS AA or 280Z AA?

This item is a flame-AA spray chamber component, not a spectrometer. Choose it when maintaining a Mark 7 burner/spray chamber assembly on an Agilent 55/240/280 flame AAS. The 240Z AA and 280Z AA siblings are graphite-furnace instruments and do not use this flame spray chamber; the 240FS AA and 280FS AA are the flame siblings in the same series.

What adjacent system parts must be compatible with this spray chamber?

It belongs to the Mark 7 burner/spray chamber family for Agilent Flame AAS (55/240/280). The flyer also lists capillary tubing (0.38 mm ID), glass impact beads, and burner-cleaning-and-alignment cards as related consumables, so the mating burner, capillary, and impact beads should be confirmed as Mark 7-compatible before installation. No drive, power supply, or controller interface is specified for this passive component.

Are there mounting or duty-cycle limits I must respect from the manual?

The supplied document digest contains no sections or actionable engineering facts, so mounting orientation, gas-pressure limits, and duty cycle for this spray chamber are not documented here. The only verified context is that it is a Mark 7 flame-AA spare part. Consult the instrument's Mark 7 burner/spray chamber manual for installation and operating limits before use.

What maintenance schedule and consumables are associated with this spray chamber, and what is not included?

The flyer positions Mark 7 burner/spray chamber items within a recommended spare-parts set that also includes hollow cathode lamps, sample-introduction parts, VGA 77 vapor-generation accessories, and SPS 4 autosampler accessories. Specific replacement intervals are not given in the digest. The base spray chamber delivery does not include the separately listed consumables such as 100 pk burner-cleaning cards, 3 pk capillary tubing, 5 pk glass impact beads, 1.1 mL vials, or the 100 µL syringe.