Agilent Technologies IDP 7 Dry Scroll Pump
Agilent Technologies IDP 7 Dry Scroll Pump — Liquid chromatography with Motor power 2.24 kW.
The IDP-7 is a single-hermetic dry scroll vacuum pump delivered in low-voltage (100–120 VAC) and high-voltage (200–240 VAC) configurations, with an optional integral inlet isolation valve. It reaches 20 mT at 60 Hz (30 mT at 50 Hz) and pumps 152 L/min at 60 Hz (120 L/min at 50 Hz), serving as an oil-free backing or roughing stage for analytical instruments and clean vacuum systems.
Full specifications
| Motor power | 3 HP |
| Coverslip type | No corrosive, explosive or particulate forming gases |
| Dimensions | 248 mm |
| Inlet Pressure | 1.0 atm |
| Operating Speed | 1450 RPM |
| Water Vapor Handling Per Pneurop 6602 | 120 g/hr |
| Peak pumping speed mfr | 50 L/min |
| Maximum recommended continuous inlet pressure mfr | 150 T |
| Maximum outlet pressure mfr | 5 psig |
| Exhaust connection mfr | 16 |
| Gas ballast mfr | 1 |
| Motor thermal protection mfr | Automatic thermal protection protection |
| Leak rate (with exhaust sealed) mfr | 1 helium |
| Hour meter mfr | 1 hour |
| Emissions and Immunity mfr | 61236 device |
| Safety mfr | 61010 Canada |
| Installation mfr | 2 |
| Ultimate pressure mfr | 30 mT |
| Europe mfr | 10 m |
| Denmark mfr | 10 m |
| Switzerland mfr | 10 m |
| UK/Ireland mfr | 13 m |
| India mfr | 10 m |
| Israel mfr | 10 m |
| Japan mfr | 12 m |
| North America mfr | 15 m |
| Operating voltages** mfr | 100 phase |
| Will not start mfr | Fuse blown blown |
| Poor ultimate pressure mfr | System leak leak |
| Pump runs intermittently mfr | Motor thermal protector is cycling open and clos |
| Service, Maintenance, Tip Seal, or Part Replacement mfr | Wear or damage damage |
| X3807-67002 mfr | Front Cowling Assembly Assembly |
| X3807-67003 mfr | Rear Cowling Assembly Assembly |
| X3807-68008 mfr | Gas Ballast Kit Kit |
| Fax: 00 39 011 9979 330 mfr | 1 |
| Fax Free: 00 800 345 00 mfr | 800 |
| Toll Free: 00 800 234 00 mfr | vpl-ra@agilent.com agilent.com |
| Clearance around pump mfr | 60 cm |
| Extension cord wire gauge mfr | 16 wire |
| Water vapor handling with both gas ballast ports mfr | 120 g/hr |
| Dry nitrogen flow for gas ballast mfr | 5 l/min |
| Tip seal M5 bolt torque mfr | 4 m |
| Shipping Weight | 28.1 kg |
| Weight | 24.5 kg |
| Extension cord maximum length mfr | 25 feet |
| Typical Maximum Starting Current | 22 A |
| Operating voltages mfr | 100 VAC |
| Fuse Type mfr | 5 equivalent |
| Power cord capacity mfr | 10 A |
| Inlet flange | 25 |
| Cooling System | Air-cooled |
| Operating temperature | 5 °C |
| Storage temperature | 20...60 °C |
| Ambient Relative Humidity mfr | 5 condensing |
| Altitude mfr | 2000 m |
| Hammering noise mfr | Pump overheated overheated |
| Noise Level (per ISO 11201) mfr | 52 dB |
| Vibration level at inlet (per ISO 10816-1) mfr | 1 mm/s |
Description
Construction and series positioning
- Single-hermetic dry scroll architecture: no oil, no sliding vanes; only air or inert gases are permitted (no corrosive, explosive, or particulate-forming gases).
- Delivered factory-set for high voltage (200–240 VAC); a voltage selector switch must be moved to 115 for low-voltage (100–120 VAC) operation.
- Two mains-frequency performance points define the model: 152 L/min and 20 mT at 60 Hz versus 120 L/min and 30 mT at 50 Hz. There are no other series siblings in the supplied data, so the IDP-7 is positioned by its voltage/frequency configuration and by the presence or absence of the optional inlet isolation valve.
- Air-cooled, 24.5 kg, 248 mm high; inlet connection 25, exhaust connection 16, gas ballast ports 1 and 2.
Behavior under load and media
- Maximum recommended continuous inlet pressure is 150 T (200 mbar); continuous operation above this risks overheating and tip-seal wear.
- Maximum outlet pressure is 5 psig at 115 VAC or greater, derating linearly to 0 psig at 90 VAC; likewise 5 psig at 230 VAC or greater, derating to 0 psig at 180 VAC. Exhaust restrictions must be kept small, especially at low line voltage.
- Water-vapor handling: gas ballast port 1 for moderate loads, port 2 for high loads; with both in use the pump handles up to 120 g/hr. For dry-nitrogen purge, supply approximately 5 L/min at the gas ballast inlet via 1/4 NPT.
- Ultimate pressure is reached only after at least 24 hours of running with the inlet sealed; new or atmosphere-exposed pumps should be run with GB1 open for 15 minutes and/or flushed with dry nitrogen to remove water.
Installation, control and operation
- The optional isolation valve opens 30 seconds after pump start and closes immediately on power loss or switch-off, allowing the pump to reach speed before chamber exposure and preventing backstreaming.
- Motor thermal protection is automatic (auto-reset); a 5×20 mm, 10 A Slo-Blo fuse (Littelfuse 215010 or equivalent) is required to withstand starting inrush.
- Typical maximum starting current ranges from 12 A to 25 A depending on voltage and frequency (e.g., 25 A at 120 V 60 Hz, 12 A at 200 V 60 Hz).
- Extension cords must be minimum 16-gage, maximum 25 ft (7.6 m), 3-wire with ground.
- Noise is 52 ±2 dB(A) per ISO 11201; an exhaust silencer option is available. Leak rate is <1×10⁻⁶ helium with exhaust sealed.
Integration & Operating Notes
The pump leaves the factory configured for 200–240 VAC. Applying 100–120 VAC without moving the selector to 115, or the reverse, can damage the motor and invalidate the installation. Confirm the selector position and the correct 10 A Slo-Blo fuse (5×20 mm) before energizing.
Starting current can reach 25 A at 120 V 60 Hz and 12 A at 200 V 60 Hz. Breakers, wiring, and any extension cord must be rated for this inrush; use only 16-gage or heavier 3-wire grounded cords up to 25 ft (7.6 m). Undersized or long cords cause voltage drop, loss of power, and overheating.
Continuous operation above 150 T (200 mbar) overheats the pump and accelerates tip-seal wear. For processes that routinely run at higher pressure, throttle the inlet or select a larger pump rather than relying on the IDP-7 to hold the load.
Maximum outlet pressure is 5 psig at 115 VAC or greater, falling linearly to 0 psig at 90 VAC; similarly 5 psig at 230 VAC or greater, falling to 0 psig at 180 VAC. Any exhaust restriction, filter, or long exhaust line must be sized so that backpressure stays within the value corresponding to the actual line voltage.
The pump is air-cooled and its surface can exceed 65 °C (150 °F), which is potentially damaging. Install with at least 60 cm (24 in) of clear space on all sides for ventilation and access, keep fan ducts unobstructed, and operate only within 5–40 °C ambient and 5–95% relative humidity (up to 2000 m altitude).
Use gas ballast port 1 for moderate water-vapor loads and port 2 for high loads; with both ports in use the pump can handle up to 120 g/hr. For dry-nitrogen purge, supply approximately 5 L/min at the gas ballast inlet through a 1/4 NPT connection. After exposure to atmosphere, open GB1 for 15 minutes and/or flush with dry nitrogen before expecting ultimate pressure.
With the optional integral inlet isolation valve, the valve opens 30 seconds after pump start and closes immediately on power loss or switch-off. Sequence chamber exposure and venting around this delay; the pump must reach operating speed before the chamber is connected, and the valve prevents backstreaming on shutdown.
Tip-seal replacement uses kit P/N X3807-67000 (seals and O-rings). During reassembly, torque the four M5 frame bolts to 4 N·m (40 in-lbs) to ensure proper sealing and avoid damage to the scroll housing. New tip seals may require several hours of running to seat before ultimate pressure is recovered.
To reach maximum vacuum, leave the pump running for at least 24 hours with the inlet sealed. If the pump or system is new or has been exposed to atmosphere, first open GB1 for 15 minutes and/or flush with dry nitrogen to remove water; otherwise the specified 20 mT (60 Hz) or 30 mT (50 Hz) ultimate pressure will not be achieved.
Selection & Integration Q&A
Choose the IDP-7 when your required flow and base pressure match its frequency point: 152 L/min and 20 mT at 60 Hz, or 120 L/min and 30 mT at 50 Hz. Select the low-voltage (100–120 VAC) or high-voltage (200–240 VAC) build to suit your mains, and add the optional inlet isolation valve if the chamber must be protected from backstreaming on power loss.
Provide a grounded supply matching the selected voltage configuration (100–120 VAC or 200–240 VAC) and a circuit rated for 12–25 A starting inrush. Fit the specified 5×20 mm, 10 A Slo-Blo fuse (Littelfuse 215010 or equivalent); fast-blow fuses will nuisance-trip. Extension cords must be 16-gage minimum, 3-wire with ground, and no longer than 25 ft (7.6 m).
The base delivery does not include the tip-seal replacement kit P/N X3807-67000 (seals and O-rings), the optional inlet isolation valve, the exhaust silencer, or country-specific power cords. Plan for tip-seal replacement with the kit and torque the four M5 frame bolts to 4 N·m (40 in-lbs); new seals may need several hours to seat.