BINDER FD-S 115
BINDER FD-S 115 — Drying ovens with Temperature 10…250 °C.
The FD-S 115 is a forced-convection drying and heating oven with a 106 L stainless-steel chamber (550 × 550 × 350 mm) and an R-S PID controller, operating from +10 to 250 °C. Within the FD-S series it is the larger 115-size chamber, distinguished from the 56-size sibling by volume and load capacity (75 kg total, 20 kg per rack). It is intended for reproducible drying, heating and thermal treatment of harmless materials where forced air circulation and defined air-change rate are required.
BINDER FD-S Series — Model Comparison & Selection
| Model | Temperature, °C | Air change rate, 1/hour | Depth, mm | Heating up time to 150 c, min | Height, cm | Interior depth, mm |
|---|---|---|---|---|---|---|
| FD-S 115 Current | 10–250 | 2 | 616 | 20 | 73.5 | 350 |
| FD-S 56 | 10–250 | 4 | 577 | 15 | 62.5 | 310 |
Full specifications
| Temperature | 10...250 °C |
| Air change rate | 2 x/h |
| Heating time to 150°C | 20 min |
| Interior volume | 106 L |
| Load per rack | 20 kg (FDS115-230V) |
| Nominal power | 1.3 kW |
| Permitted load | 75 kg (FDS115-230V) |
| Temperature fluctuation | 0.4 K |
| Temperature uniformity | 2.0 K |
| Rear wall clearance | 160 mm (FDS115-230V) |
| Side wall clearance | 100 mm (FDS115-230V) |
| Article Number mfr | 9090 |
| Recovery time after door was opened for 30 s at 150°C mfr | 8 min |
| Depth | 616 mm (FDS115-230V) |
| Height | 735 mm (FDS115-230V) |
| Interior depth | 350 mm (FDS115-230V) |
| Interior height | 550 mm (FDS115-230V) |
| Interior width | 550 mm (FDS115-230V) |
| Width | 764 mm (FDS115-230V) |
| Net weight of the unit (empty) mfr | 48 kg |
| Power frequency | 50 Hz |
| Rated voltage | 230 V |
| Unit fuse | 6.3 A |
| Phase (Nominal voltage) mfr | 1 |
Description
Construction and series positioning
The FD-S 115 (Art. No. 9090-0024, designation 115-230) is the 230 V, 50 Hz variant of the 115-size forced-convection oven. The interior and door interior are stainless steel 1.4016 (AISI 430); the housing is polyester-coated RAL 9003. Compared with the FD-S 56 sibling, the 115 offers a 106 L interior instead of the smaller 56-size chamber, with net dimensions of 764 × 735 × 616 mm and a net weight of 48 kg. Unlike the natural-convection ED-S line, the FD-S uses forced-air circulation, which supports faster heat-up (20 min to 150 °C) and defined air exchange.
Thermal behaviour and control
- Working range: +10 to 250 °C, with a display resolution of 1 °C (typical for the ED-S/FD-S oven line; the BD-S incubator line offers 0.1 °C).
- Temperature fluctuation is 0.4 K and temperature uniformity 2.0 K, measured under the factory conditions of the 115-230 V variant.
- Recovery time after a 30 s door opening at 150 °C is 8 min.
- Air-change rate is 2 ×/h, adjustable via the exhaust air flap as described in the operating manual.
- Heating power is 1.3 kW at 230 V single-phase; the chamber fuse is 6.3 A.
- Overtemperature protection class 1 per DIN 12880 is standard; the safety controller is class 2 for the FD-S line.
Installation and operation
- Electrical: 230 V 1~ 50 Hz, grounded CEE 7/7 plug, 6.3 A fusing; voltage tolerance ±10 %.
- Clearances: 160 mm at the rear and 100 mm at the sides; do not install in unventilated recesses.
- Load limits: 75 kg total permitted load, 20 kg per rack.
- The R-S microprocessor controller handles set-point entry, °C/°F selection, delayed-off timer and safety-controller settings.
- Maintenance: at least annually, with repeat electrical inspection per EN 50678/VDE 0701 and EN 50699/VDE 0702.
Integration & Operating Notes
The chamber is rated for 230 V 1~ 50 Hz with a 6.3 A fuse and 1.3 kW nominal power. Operating outside the ±10 % voltage tolerance stated on the type plate can cause controller faults and invalid thermal results; verify mains quality and provide a protective-earth connection before commissioning.
The 115-230 V variant requires 160 mm wall clearance at the back and 100 mm at the sides. Installing the chamber in an unventilated recess or closer than these distances prevents heat dispersal and can lead to overheating damage; the manual explicitly prohibits unventilated recess installation.
The chamber has no explosion-protection measures. Do not introduce combustible or explosive substances, and ensure the operating temperature remains below the flash point or sublimation point of the load. Corrosive materials (acids, halides) can attack the 1.4016 stainless steel interior and are excluded from liability.
The permitted load for the 115-230 V variant is 75 kg overall, with a maximum of 20 kg per rack. Exceeding these limits can deform racks or the chamber floor and compromise temperature uniformity; distribute loads evenly across racks.
The FD-S line uses an overtemperature safety controller of class 2 per DIN 12880, in addition to the standard class 1 protective device. Set the safety-controller cut-out above the working set-point but below the load's critical temperature, and verify alarm response before leaving the chamber unattended.
Plan maintenance at least once a year, including repeat electrical inspection per EN 50678/VDE 0701 and EN 50699/VDE 0702 before initial start-up and after any repair. Disconnect the power plug before service; do not remove the rear panel; replace the door gasket only when cold.
The 2 ×/h air-change rate is adjusted at the exhaust air flap during start-up. If an external exhaust connection is used, account for the additional ventilation path when setting the flap, since it affects both the air-change rate and the thermal uniformity inside the 106 L chamber.
Selection & Integration Q&A
Choose the FD-S 115 when the 106 L interior and 75 kg total load (20 kg per rack) are needed for larger batches or bulky parts. The FD-S 56 is preferable for smaller loads where its reduced chamber volume heats faster and uses less bench space; both share the +10 to 250 °C range and forced convection.
It requires 230 V 1~ 50 Hz with protective earth, a CEE 7/7 grounded plug and a 6.3 A chamber fuse; nominal power is 1.3 kW. A standard grounded outlet is acceptable provided the supply stays within ±10 % of nominal voltage and the circuit is fused at 6.3 A.
Install with 160 mm rear and 100 mm side clearance, never in an unventilated recess. Transport/storage limits are -10 to +60 °C and max. 70 % r.h. non-condensing; after cold storage, wait at least one hour at ambient temperature and ensure the chamber is dry before start-up.
Plan annual maintenance and repeat electrical inspection per EN 50678/VDE 0701 and EN 50699/VDE 0702. Racks, exhaust/ventilation connections and spare door gaskets are accessories/spare parts not included in base delivery; order them separately. Replace the door gasket only when cold.