Elmo Rietschle IDP
Elmo Rietschle IDP — Screw Vacuum Pumps with Motor power 22 kW, Pumping speed 1030 m³/h, Ultimate pressure 5 mbar.
The IDP is a dry screw vacuum pump with a 22 kW motor (IDP1100) or 18.5 kW motor (IDP850), achieving an ultimate pressure of 0.005 mbar and pumping speeds of 1030 m³/h and 850 m³/h respectively. It is distinguished within the series by its motor power and rotational speed (3600 rpm for IDP1100, 3300 rpm for IDP850), while sharing the same ISO100 inlet and DN100 PN10/ISO80 outlet connections. This pump is intended for clean, dry vacuum applications in industrial processes where oil-free operation and high pumping speed are required.
Full specifications
| Motor power | 18.5 kW (IDP850) IDP1100: 22 kW |
| Pumping speed | 850 m³/h (IDP850) IDP1100: 1030 m³/h |
| Ultimate pressure | 0.005 mbar (IDP850) IDP1100: 0.005 mbar |
| Rotational speed | 3300 rpm (IDP850) IDP1100: 3600 rpm |
| Height | 787 mm (IDP850 / IDP1100) |
| Length | 1907 mm (IDP850 / IDP1100) |
| Weight | 1055 kg (IDP850 / IDP1100) |
| Width | 868 mm (IDP850 / IDP1100) |
| Inlet flange | ISO100 (IDP850 / IDP1100) |
| Outlet flange | DN100 PN10 / ISO80 (IDP850 / IDP1100) |
| Noise level | 60 dB (IDP850) IDP1100: 61 dB |
| Operating temperature | 5~46 °C (IDP850 / IDP1100) |
Description
Construction and Positioning
- The IDP is a dry screw vacuum pump available in two power variants: IDP850 (18.5 kW) and IDP1100 (22 kW). Both share the same footprint (1907 mm L × 868 mm W × 787 mm H) and weight (1055 kg).
- The series also includes IDS models, which differ in motor type (fixed vs variable frequency), cooling method (air vs water), and controller options (none vs PLC touch screen). The IDP variant is distinguished by its higher motor power and rotational speed, targeting higher pumping speeds.
- The pump is designed for oil-free operation, making it suitable for processes where contamination is a concern.
Performance Characteristics
- Ultimate pressure is 0.005 mbar for both variants, indicating identical sealing and rotor design.
- Pumping speed differs: IDP850 delivers 850 m³/h, while IDP1100 delivers 1030 m³/h, due to the higher motor power and rotational speed (3300 rpm vs 3600 rpm).
- Noise levels are 60 dB(A) for IDP850 and 61 dB(A) for IDP1100, reflecting the increased speed of the larger model.
- The pump operates within an ambient temperature range of 5–46 °C.
Installation and Operation
- Inlet connection is ISO100, outlet is DN100 PN10 / ISO80, allowing integration with standard vacuum fittings.
- The pump requires a suitable controller or starter for the motor; the series offers variants with or without a PLC touch screen controller. For the IDP, the motor is fixed-speed, so a direct-on-line or soft starter is typical.
- Cooling method is not specified in the provided facts; however, the series includes air and water cooling options. The IDP likely uses air cooling (as the IDS variant may offer water cooling), but this should be confirmed with the manufacturer.
- Regular maintenance includes inspecting the screws for wear, though the pump is dry-running.
Integration & Operating Notes
The pump weighs 1055 kg and generates vibration during operation. Mount on a rigid, level surface capable of withstanding the static weight and dynamic forces. Use appropriate anchor bolts and vibration isolators if necessary to prevent transmission to the building structure.
The motor is rated at 22 kW for IDP1100 and 18.5 kW for IDP850. Ensure the power supply can deliver the required current and voltage (typically 400 V, 50 Hz or 460 V, 60 Hz). Use proper overload protection and wiring sized for the full load current. Consult the motor nameplate for exact electrical data.
The pump achieves an ultimate pressure of 0.005 mbar. It is designed for continuous operation at inlet pressures down to this ultimate pressure. Operating at higher pressures may cause overheating or increased wear. Ensure the process gas is clean and dry, as the pump is oil-free and not suitable for condensable or particulate-laden gases without proper filtration.
The pump is rated for ambient temperatures between 5 °C and 46 °C. Outside this range, performance and reliability may be affected. Ensure adequate ventilation in the installation area to prevent overheating, especially if the pump is enclosed.
Although the pump is dry-running, periodic inspection of the screw rotors and bearings is recommended to detect wear or debris. Follow the maintenance schedule in the manual. The pump does not require oil changes, but the bearings may be greased for life or require periodic relubrication depending on the design.
Selection & Integration Q&A
Choose IDP1100 for higher pumping speed (1030 m³/h vs 850 m³/h) and 22 kW motor. IDP850 suits lower flow needs. IDS variants offer variable frequency, water cooling, or PLC controller for more flexible process control.
Inlet is ISO100, outlet is DN100 PN10 / ISO80. Use compatible flanges and gaskets. Ensure piping supports are independent to avoid stress on pump. For outlet, consider a silencer or filter if exhaust is in a sensitive area.
Yes, the pump is designed for continuous operation at ultimate pressure of 0.005 mbar. However, ensure process gas is clean and dry. For processes with high dust or condensables, install appropriate filters or traps upstream.
Base delivery includes pump only. Required accessories: inlet filter, exhaust silencer, vibration isolators, and motor starter. Spare parts like screw rotors and bearings are available separately. Regular maintenance kits may be recommended.