Elmo Rietschle L-NEV2
Elmo Rietschle L-NEV2 — Liquid Ring Vacuum Pumps with Max inlet pressure 2.7 kPa, Motor power 0.81 kW, Pumping speed 27 m³/h.
The L-NEV2 is an oil-free liquid ring vacuum pump in the NEV2 series, operating at 50 Hz with a 0.81 kW motor and 220 V supply. It delivers 27 m³/h pumping speed at a maximum inlet pressure of 27 mbar, distinguishing it as a compact, low-capacity unit within the series. Its primary purpose is to provide clean, oil-free vacuum for processes where contamination from lubricants is unacceptable.
Full specifications
| Max inlet pressure | 27 mbar (50 Hz) |
| Motor power | 0.81 kW (50 Hz) |
| Operating principle | Liquid Ring |
| Pumping speed | 27 m³/h (50 Hz) |
| Height | 90 mm (50/60 Hz) |
| Length | 456 mm (50/60 Hz) |
| Weight | 24 kg (50 Hz) |
| Width | 186 mm (50/60 Hz) |
| Power supply | 220 V (50 Hz) |
| Noise level | 62 dB (50 Hz) |
Description
Construction and Positioning
- The L-NEV2 is a liquid ring vacuum pump. It is an oil-free design, meaning the working chamber is sealed by a liquid ring (typically water) rather than oil, eliminating oil contamination in the pumped gas.
- This model has a pumping speed of 27 m³/h at 50 Hz, suitable for small-scale applications.
- The pump is constructed with a 0.81 kW motor, designed for 220 V at 50 Hz. Dimensions are 456 mm length, 186 mm width, and 90 mm height, with a weight of 24 kg.
Performance and Behavior
- At 50 Hz, the pump achieves an ultimate pressure of 27 mbar (absolute pressure) and a pumping speed of 27 m³/h. These values are typical for liquid ring pumps in this size class, where the liquid ring limits the ultimate pressure due to vapor pressure of the service liquid.
- The pump is oil-free, so it can handle gases with high moisture content or slight particulate without oil degradation. However, performance depends on the service liquid temperature and flow; higher liquid temperatures reduce achievable vacuum.
- Noise level is 62 dB at 50 Hz, which is moderate and suitable for industrial environments with standard hearing protection.
Installation and Operation
- The pump requires a service liquid supply (usually water) to form the liquid ring. The liquid must be clean and compatible with the pump materials (cast iron or bronze/stainless steel variants). The pump is not self-priming; it needs to be filled with liquid before startup.
- Electrical connection is to a 220 V, 50 Hz supply, with a motor rated at 0.81 kW. Ensure the supply can handle the starting current, which may be several times the running current.
- The pump can be mounted in any position, but typical installation is horizontal. Inlet and outlet connections should be sized to avoid excessive pressure drop. The discharge should be piped to a safe location for the liquid and gas mixture.
- Regular maintenance includes checking the service liquid flow and temperature, and inspecting for wear or clogging. The pump has no oil to change, but the liquid ring system may require filtration.
Integration & Operating Notes
The pump achieves an ultimate pressure of 27 mbar absolute. Operating at lower absolute pressures (deeper vacuum) may cause cavitation and loss of liquid ring integrity, leading to vibration and damage. Ensure the process pressure is controlled and monitored, especially during startup or upset conditions.
The motor is designed for 220 V, 50 Hz. Operating at higher voltage or frequency can overheat the motor and void warranty. Verify supply stability and use appropriate protection.
The liquid ring performance depends on clean service liquid. Inspect filters and ensure flow rate is within specification. Contaminated liquid can cause erosion and reduced vacuum.
Selection & Integration Q&A
Choose L-NEV2 for low-capacity, oil-free vacuum needs up to 27 m³/h with an ultimate pressure of 27 mbar. Larger models like NEV2 070 offer higher flow; select based on required pumping speed and ultimate pressure.
The pump requires a continuous supply of clean, compatible liquid (typically water) at a flow rate sufficient to maintain the ring. Piping should be sized to avoid pressure drop, and discharge must handle two-phase flow.
Mount on a level surface in a well-ventilated area, ambient temperature typically 0–40°C. Avoid corrosive atmospheres unless the stainless steel variant is used. Ensure adequate clearance for maintenance.
Base delivery includes the pump only. Service liquid filtration, piping, valves, and control instruments are not included. Regular maintenance includes checking liquid quality and inspecting seals; spare parts kits are available separately.