Elmo Rietschle V-DTN
Elmo Rietschle V-DTN — Central Industrial & Medical Vacuum Systems with Max differential pressure 0.6 mbar, Noise level 63 dB, Pumping speed 20.5 m³/h.
The V-DTN is a side-channel blower configured as a compressor, delivering 17.0 m³/h at 50 Hz and 20.5 m³/h at 60 Hz with a maximum differential pressure of 0.7 mbar (50 Hz) or 0.6 mbar (60 Hz). It is distinguished within the series by its size-specific connections (Rp 1/2 for V-DTN 16/26, Rp 3/4 for V-DTN 41) and compact footprint. It serves as a low-pressure air source in central vacuum or pressure systems requiring oil-free, pulsation-free flow.
Full specifications
| Max differential pressure | 0.7 mbar (50 Hz) 60 Hz: 0.6 mbar |
| Noise level | 61 dB (50 Hz) 60 Hz: 63 dB |
| Pumping speed | 17.0 m³/hour (50 Hz) 60 Hz: 20.5 m³/hour |
| Suction connection mfr | Rp 1/2 (V-DTN 16) |
| Suction connection mfr | Rp 1/2 (V-DTN 26) |
| Suction connection mfr | Rp 3/4 (V-DTN 41) |
| Pressure connection mfr | Rp 1/2 (V-DTN 16) |
| Pressure connection mfr | Rp 1/2 (V-DTN 26) |
| Pressure connection mfr | Rp 3/4 (V-DTN 41) |
| Volumenstrom / Volume flow mfr | 17,0 m3/h (50 Hz) |
| Volumenstrom / Volume flow mfr | 20,5 m3/h (60 Hz) |
| Überdruck / Overpressure mfr | 1,0 bar (50 Hz) |
| Überdruck / Overpressure mfr | 1,0 bar (60 Hz) |
| a1 mfr | 30 mm |
| b mfr | 254 mm |
| b1 mfr | 236 mm |
| c mfr | 283 mm |
| e mfr | 180 mm |
| f mfr | 220 mm |
| l mfr | 125 mm |
| l2 mfr | 65 mm |
| m mfr | 79 mm |
| n mfr | 126 mm |
| o mfr | 150 mm |
| p mfr | 170 mm |
| r mfr | 164 mm |
| r1 mfr | 11 mm |
| v mfr | 246 mm |
| v2 mfr | 14 mm |
| R1 mfr | Rp 1/2 |
| Überdruck (alt 50 Hz) mfr | 1,0 mbar (50 Hz) |
| Overpressure (alt 60 Hz) mfr | 1,0 mbar (60 Hz) |
| Weight | 29 kg (3~) 1~: 29 kg |
| Dimension a1 mfr | 30 mm (V-DTN 16) |
| Dimension a1 mfr | 33 mm (V-DTN 26) |
| Dimension a1 mfr | 42 mm (V-DTN 41) |
| Dimension b mfr | 254 mm (V-DTN 16) |
| Dimension b mfr | 254 mm (V-DTN 26) |
| Dimension b mfr | 275 mm (V-DTN 41) |
| Dimension b1 mfr | 236 mm (V-DTN 16) |
| Dimension b1 mfr | 236 mm (V-DTN 26) |
| Dimension b1 mfr | 270 mm (V-DTN 41) |
| Dimension c mfr | 283 mm (V-DTN 16) |
| Dimension c mfr | 283 mm (V-DTN 26) |
| Dimension c mfr | 319 mm (V-DTN 41) |
| Dimension e mfr | 180 mm (V-DTN 16) |
| Dimension e mfr | 180 mm (V-DTN 26) |
| Dimension e mfr | 200 mm (V-DTN 41) |
| Dimension f mfr | 220 mm (V-DTN 16) |
| Dimension f mfr | 220 mm (V-DTN 26) |
| Dimension f mfr | 242 mm (V-DTN 41) |
| Dimension l mfr | 125 mm (V-DTN 16) |
| Dimension l mfr | 125 mm (V-DTN 26) |
| Dimension l mfr | 147 mm (V-DTN 41) |
| Dimension l2 mfr | 65 mm (V-DTN 16) |
| Dimension l2 mfr | 65 mm (V-DTN 26) |
| Dimension l2 mfr | 72 mm (V-DTN 41) |
| Dimension m mfr | 79 mm (V-DTN 16) |
| Dimension m mfr | 79 mm (V-DTN 26) |
| Dimension m mfr | 90 mm (V-DTN 41) |
| Dimension n mfr | 126 mm (V-DTN 16) |
| Dimension n mfr | 161 mm (V-DTN 26) |
| Dimension n mfr | 175 mm (V-DTN 41) |
| Dimension o mfr | 150 mm (V-DTN 16) |
| Dimension o mfr | 150 mm (V-DTN 26) |
| Dimension o mfr | 190 mm (V-DTN 41) |
| Dimension p mfr | 170 mm (V-DTN 16) |
| Dimension p mfr | 170 mm (V-DTN 26) |
| Dimension p mfr | 210 mm (V-DTN 41) |
| Dimension r mfr | 164 mm (V-DTN 16) |
| Dimension r mfr | 164 mm (V-DTN 26) |
| Dimension r mfr | 201 mm (V-DTN 41) |
| Dimension r1 mfr | 11 mm (V-DTN 16) |
| Dimension r1 mfr | 11 mm (V-DTN 26) |
| Dimension r1 mfr | 10 mm (V-DTN 41) |
| Dimension v mfr | 246 mm (V-DTN 16) |
| Dimension v mfr | 246 mm (V-DTN 26) |
| Dimension v mfr | 282 mm (V-DTN 41) |
| Dimension v2 mfr | 14 mm (V-DTN 16) |
| Dimension v2 mfr | 14 mm (V-DTN 26) |
| Dimension v2 mfr | 8 mm (V-DTN 41) |
| Average noise level (EN ISO 3744) mfr | 61 dB (50 Hz) |
| Average noise level (EN ISO 3744) mfr | 63 dB (60 Hz) |
Description
Construction and series positioning
The V-DTN is a side-channel (regenerative) blower from Elmo Rietschle, available in sizes 16, 26, and 41. This model code covers the base configuration with either 3~ IE3 motors (GX, GA, GB, GD, GE) or 1~ motors, for 50 Hz or 60 Hz operation. The suction and pressure connections are Rp 1/2 for sizes 16 and 26, and Rp 3/4 for size 41. Overall dimensions vary by size: dimension b is 254 mm for 16/26 and 275 mm for 41; dimension c is 283 mm for 16/26 and 319 mm for 41. Weight is 29 kg for both 3~ and 1~ variants.
Performance and operating behavior
At 50 Hz, the V-DTN delivers 17.0 m³/h pumping speed and a maximum differential pressure of 0.7 mbar; at 60 Hz, these are 20.5 m³/h and 0.6 mbar. Noise level is 61 dB at 50 Hz and 63 dB at 60 Hz. The side-channel principle provides oil-free, pulsation-free air flow, making it suitable for continuous duty in central vacuum or pressure systems. No digitized curve points are available; refer to the technical data sheet for detailed performance curves.
Installation and connections
Mounting dimensions are provided per size: for V-DTN 16/26, dimension a1 is 30/33 mm, b1 is 236 mm, e is 180 mm, f is 220 mm, l is 125 mm, and l2 is 65 mm; for V-DTN 41, a1 is 42 mm, b1 is 270 mm, e is 200 mm, f is 242 mm, l is 147 mm, and l2 is 72 mm. The blower can be installed in any orientation, but ensure sufficient clearance for motor cooling. Electrical connection must match the motor variant: 3~ IE3 motors require a suitable starter with overload protection; 1~ motors are supplied with capacitor and require a dedicated circuit. Control and I/O are not integrated; external contactors or variable frequency drives (for 3~) must be provided by the installer.
Integration & Operating Notes
The blower must be bolted down using all four mounting points to a rigid, flat surface. Excessive vibration from improper mounting can lead to bearing damage and increased noise. Use anti-vibration mounts if the structure is flexible.
3~ IE3 motors must be connected via a contactor with thermal overload protection set to the motor's full-load current. For 1~ motors, ensure the capacitor is correctly wired and protected. Incorrect protection can void warranty and cause motor burnout.
If a suction filter is fitted, inspect and clean it periodically; a clogged filter reduces performance and can cause overheating. Replace the filter if damaged. Refer to the spare parts list for filter part numbers specific to V-DTN 16 and V-DTN 26; for V-DTN 41, consult the spare parts list for the applicable filter part number.
The V-DTN is a bare-shaft blower without built-in control electronics. The installer must provide motor starting equipment, overload protection, and any required sensors or switches for system integration.
Selection & Integration Q&A
Choose V-DTN 16 or 26 for Rp 1/2 connections; V-DTN 41 offers Rp 3/4 connections. The published pumping speed of 17.0 m³/h at 50 Hz and 20.5 m³/h at 60 Hz applies to the V-DTN series; size-specific flow figures are not provided in the verified data. Select based on required connection size and confirm performance from the technical data sheet.
For 3~ IE3 motors, provide a contactor with thermal overload protection set to motor FLC. For 1~ motors, ensure correct capacitor wiring and dedicated circuit. Supply voltage must match motor nameplate (e.g., 230/400 V or 230/460 V).
The base delivery excludes suction filter, pressure relief valve, and motor starter. Spare parts such as filters and gaskets are listed in the Spare Parts List E381. If a suction filter is fitted, regular cleaning is recommended.