Elmo Rietschle V-DTR
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle V-DTR

Elmo Rietschle V-DTR — Central Industrial & Medical Vacuum Systems with Max differential pressure 1000 mbar, Motor power 6.5 kW, Noise level 79 dB.

The V-DTR is a single-stage, dry-running rotary vane compressor with an eccentrically mounted rotor and vanes, driven by a flanged three-phase motor via a coupling. This modification delivers 100 m³/h at 50 Hz (120 m³/h at 60 Hz) and up to 0.8 bar differential pressure (1.0 bar at 60 Hz), positioning it as the mid-capacity unit in the V-DTR 100/140 series. It is intended for continuous oil-free air supply in central vacuum/pressure systems where 30–90% relative humidity air is conveyed.

Max differential pressure
1000 mbar
Motor power
6.5 kW
Noise level
79 dB
Pumping speed
120 m³/h
Weight
148 kg

Full specifications

Core Performance & Functional Specifications
Max differential pressure 0.8 bar (50 Hz)
60 Hz: 1.0 bar
Motor power 4.0 kW (50 Hz)
60 Hz: 6.5 kW
Noise level 75 dB (50 Hz)
60 Hz: 79 dB
Pumping speed 100 m³/hour (50 Hz)
60 Hz: 120 m³/hour
Rotational speed 1455 rpm (50 Hz)
60 Hz: 1740 rpm
Capacity mfr 100 m3/h (50 Hz)
Capacity mfr 100 m3/h (60 Hz)
Overpressure mfr 0.8 bar (50 Hz)
Overpressure mfr 1.0 bar (60 Hz)
Motor efficiency mfr 88.6 % (50 Hz)
Motor efficiency mfr 91.7 % (60 Hz)
Volumenstrom | Capacity (alt 50 Hz) mfr 130 m**3/hour (50 Hz)
Volumenstrom | Capacity (alt 60 Hz) mfr 155 m**3/hour (60 Hz)
Überdruck | Overpressure (alt 50 Hz) mfr 1,4 bar (50 Hz)
Überdruck | Overpressure (alt 60 Hz) mfr 1,2 bar (60 Hz)
speed | Speed (alt 50 Hz) mfr 1450 rpm (50 Hz)
Dimensions, Weight & Mechanical Design
Weight 148 kg
Max. weight | Max. weight (alt var) mfr 174 kg
Electrical, Power & Drive Specifications
Current 13.9 / 8.0 A (50 Hz)
60 Hz: 12.8 / 7.4 A
Voltage 230 / 400 V ± 10 % V (50 Hz)
60 Hz: 380 / 660 V ± 10 % V
Motor rating mfr 6.5 kW (60 Hz)
Rated voltage mfr 380/660 V (60 Hz)
Voltage tolerance mfr ±10 %
Current drawn mfr 12.8/7.4 A (60 Hz)
Bemessungsspannung | Rated voltage (alt 50 Hz) mfr 400 / 690 V ± 10 % V (50 Hz)
Motorleistung | Motor rating (alt 50 Hz) mfr 7,5 kW (50 Hz)
Motorleistung | Motor rating (alt 60 Hz) mfr 9,0 kW (60 Hz)
Stromaufnahme | Current drawn (alt 50 Hz) mfr 14,4 / 8,36 A (50 Hz)
Stromaufnahme | Current drawn (alt 60 Hz) mfr 17,8 / 10,2 A (60 Hz)
Operating Conditions, Environment & Protection
Protection rating IP 55
Operating temperature F
Average noise level mfr 79 dB(A) (60 Hz)
Mittlerer Schalldruckpegel | Average noise level (alt 50 Hz) mfr 77 dB (50 Hz)

Description

Construction and series positioning

Behavior under load and media

Installation, connection and control

Integration & Operating Notes

Mounting
Horizontal mounting with max. 10° inclination and 40 cm clearance

The machine must be set up horizontally on a level floor able to carry its weight, with no external vibrations, and secured against tipping or falling. At least 40 cm free space around the machine is required for pipe installation and maintenance access. Cooling air inlets and outlets must be at least 10 cm from adjacent walls, and recirculation of hot exhaust air must be prevented to avoid overheating.

Operating Instructions BA 361-EN, Chapter 5.1 and 5.2

Selection & Integration Q&A

When should I choose the V-DTR 100 over the V-DTR 140 in the series?

Choose the V-DTR 100 when your required flow is around 100 m³/h at 50 Hz and differential pressure up to 0.8 bar. The V-DTR 140 delivers 140 m³/h at 50 Hz and 7.5 kW motor power, so select it for higher flow or power demands. The V-DTR 100 is the more compact, lower-power option for mid-range duties.

What are the requirements for connecting the V-DTR 100 to outlet piping and parallel machines?

Pipes must be screwed in by hand only; use flexible connections if necessary. For connection pipes with the same cross-section as the machine connection and longer than 3 m, a non-return valve (accessory ZRK) is recommended to prevent reverse running after stop. For parallel operation of multiple machines, an external non-return valve must be installed in the inlet line upstream of each machine.

What are the mounting and ambient limits for the V-DTR 100?

Mount horizontally on a level floor with max. 10° inclination in all directions, secured against tipping. Allow at least 40 cm clearance around the machine for maintenance, and keep cooling air inlets/outlets at least 10 cm from walls. Ambient and inlet temperature must be 5–40°C; avoid recirculation of hot exhaust air. Above 1000 m altitude, output reduction is noticeable—consult manufacturer.

What maintenance items and accessories are not included in the base delivery but are needed for reliable operation?

The base delivery does not include the main switch and motor protection switch (to be provided by the operating company), nor the non-return valve ZRK (accessory) recommended for long outlet pipes. Spare parts such as filter cartridges (replace every 6 months), vanes (check at 3,000 h), and bearings (A bearing at 20,000 h) are consumables. A phase sequence indicator is needed for rotation check.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Operating Instructions — compressor (BA 361-EN, ed. 1.1 09/08/2023, EN)
Manual ·2,0 МБ ·34 pp.
View PDF
PDF
Technical Data Sheet — IE3 compressor DE/EN)
Datasheet ·398,9 КБ ·3 pp.
View PDF
PDF
Spare Parts List — (E 361, EN)
Spare parts ·347,3 КБ ·2 pp.
View PDF