Elmo Rietschle V-VCA
Elmo Rietschle V-VCA — Central Industrial & Medical Vacuum Systems with Motor power 0.9 kW, Noise level 59 dB, Pumping speed 30 m³/h.
The V-VCA 25 is a single-stage oil-flooded rotary vane vacuum pump with G3/4 inlet and G1/2 outlet, air-cooled and close-coupled to a 0.75 kW (50 Hz) / 0.9 kW (60 Hz) flange motor. It delivers 25 m³/h at 50 Hz and 30 m³/h at 60 Hz with an ultimate pressure of 0.5 mbar, and is the fine-vacuum member of the V Series, distinguished from the V-VCE 25 by its continuous intake range of 0.5–130 mbar (abs.) at 50 Hz. It is intended for continuous fine-vacuum duty in central industrial vacuum systems, evacuating closed volumes no larger than 2 % of nominal pumping capacity.
Full specifications
| Motor power | 0.75 kW (50 Hz) 60 Hz: 0.9 kW |
| Noise level | 57 dB (50 Hz) 60 Hz: 59 dB |
| Pumping speed | 25 m³/hour (50 Hz) 60 Hz: 30 m³/hour |
| Ultimate pressure | 0.5 mbar |
| Rotational speed | 1420 rpm (50 Hz) 60 Hz: 1720 rpm |
| Nominal suction capacity mfr | 25 m3/h (50 Hz) |
| Nominal suction capacity mfr | 30 m3/h (60 Hz) |
| Intake pressure range mfr | 0,5 – 130 mbar (abs.) (50 Hz) |
| Intake pressure range mfr | 0,5 – 100 mbar (abs.) (60 Hz) |
| Motor version mfr | UA IE3 |
| Motor speed mfr | 1720 min-1 (60 Hz) |
| Nennsaugvermögen / Nominal suction capacity mfr | 25 m3/h (50 Hz) |
| Nennsaugvermögen / Nominal suction capacity mfr | 30 m3/h (60 Hz) |
| Weight | 22 kg GA IE3: 13.5 kg |
| Length | 466 mm |
| Max. weight without motor mfr | 22 kg |
| Motor weight mfr | 15.0 kg |
| max. weight ohne Motor / max. Weight without motor mfr | 22 kg |
| Current | 2.82 / 1.62 A (50 Hz) 60 Hz: 2.90 / 1.67 A |
| Voltage | 230 / 400 V (50 Hz) 60 Hz: 265 / 460 V |
| Motor voltage mfr | 330 | 380 / 660 V ± 10 % (50 Hz) |
| Motor current mfr | 1.96 | 1.71 / 0.982 A (50 Hz) |
| Motor voltage mfr | 220 / 380 | 440 V ± 10 % (60 Hz) |
| Motor current mfr | 3.49 / 2.02 | 1.75 A (60 Hz) |
| Motor voltage GA IE3 mfr | 230 / 400 V ± 10 % (50 Hz) |
| Motor voltage GA IE3 mfr | 265 / 460 V ± 10 % (60 Hz) |
| Motor speed GA IE3 mfr | 1420 min-1 (50 Hz) |
| Motor speed GA IE3 mfr | 1720 min-1 (60 Hz) |
| Motor current GA IE3 mfr | 2,82 / 1,62 A (50 Hz) |
| Motor current GA IE3 mfr | 2,90 / 1,67 A (60 Hz) |
| Motor voltage UA IE3 mfr | 330|380 / 660 V ± 10 % (50 Hz) |
| Motor voltage UA IE3 mfr | 220 / 380|440 V ± 10 % (60 Hz) |
| Motor current UA IE3 mfr | 1,96|1,71 / 0,982 A (50 Hz) |
| Motor current UA IE3 mfr | 3,49 / 2,02|1,75 A (60 Hz) |
| Motor weight UA IE3 mfr | 15,0 kg |
| Inlet connection | G3/4 |
| Outlet connection | G1/2 |
| Oil capacity mfr | 1.0 l |
| Öleinfüllmenge / Oil capacity mfr | 1,0 l |
| Cooling type | Air cooling |
| Average noise level mfr | 59 dB(A) (60 Hz) |
| Ultimate vacuum (standard) mfr | 0.5 mbar (abs.) |
| Enddruck (Standard) / Ultimate vacuum (standard) mfr | 0,5 mbar (abs.) |
| Mittlerer Schalldruckpegel / Average noise level (EN ISO 3744) mfr | 57 dB(A) (50 Hz) |
| Mittlerer Schalldruckpegel / Average noise level (EN ISO 3744) mfr | 59 dB(A) (60 Hz) |
Description
Construction and series positioning
- Single-stage oil-flooded rotary vane pump; the V-VCA 25 and V-VCE 25 share identical construction and differ only in achievable vacuum.
- This V-VCA modification is the fine-vacuum variant: continuous intake pressure 0.5–130 mbar (abs.) at 50 Hz and 0.5–100 mbar (abs.) at 60 Hz, versus 10–500 mbar (abs.) for the V-VCE 25.
- Integrated subassemblies: vacuum connection, exhaust air outlet, filter housing, cooling-air paths, oil filling point, oil sight glass, oil discharge point, gas ballast valve and oil separator housing.
- Close-coupled 3~ flange motor in UA IE3 version; motor weight 15.0 kg, max. weight without motor 22 kg, total length 466 mm. Electrical data in the specification table apply to the UA IE3 motor; GA IE3 and TA IE3 variants are listed in the data sheet with different weights (GA IE3: 13.5 kg) and must be confirmed against the motor data plate.
- Oil capacity 1.0 l; oil viscosity must be ISO VG 100 per DIN ISO 3448.
Behavior under load and in different media
- Nominal suction capacity 25 m³/h at 50 Hz and 30 m³/h at 60 Hz with free intake; motor speed 1420 min⁻¹ (50 Hz) and 1720 min⁻¹ (60 Hz).
- Ultimate vacuum 0.5 mbar (abs.) in standard execution.
- Continuous operation outside the stated intake pressure range risks oil leakage through the outlet; the range is the defining operating envelope of this modification.
- Evacuating closed systems: the volume to be evacuated must be no more than 2 % of the nominal pumping capacity per hour (i.e. ≤ 0.5 m³ at 25 m³/h, 50 Hz; ≤ 0.6 m³ at 30 m³/h, 60 Hz).
- Maximum permissible back pressure on the exhaust side is +100 mbar; no filter may be installed on the exhaust air side.
- Average noise level 57 dB(A) at 50 Hz and 59 dB(A) at 60 Hz (EN ISO 3744).
- Output reduction is noticeable above 1000 m above sea level.
Installation, connection and operation
- Set up horizontally with max. inclination 1° in all directions on a plane, even floor able to carry the machine weight; secure against tipping and falling.
- Cooling air inlets and outlets at least 20 cm from adjacent walls; at least 40 cm free space around the machine for maintenance access.
- Permitted ambient and inlet temperature 5–40 °C; install in a ventilated room.
- Motor connection: verify the data plate against the mains; unless otherwise stated, tolerances are ±5 % voltage and ±2 % frequency. Motors comply with DIN EN 60034, IP 55, insulation class F; use an appropriate motor protection switch.
- Rotation direction: looking at the motor fan, the motor must rotate clockwise; check with a phase sequence indicator before continuous operation.
- After first start, stop the motor after 2 minutes and top oil up to the upper edge of the sight glass; repeat until all oil pipes are filled. The filling point must not be open while the pump is running.
- Check oil level daily.
Integration & Operating Notes
Operating the V-VCA 25 continuously outside its fine-vacuum intake range risks oil leakage through the outlet. At 60 Hz the upper limit drops to 100 mbar (abs.). Size the process so the pump does not run continuously in rough-vacuum conditions; for rough vacuum duty the V-VCE 25 is the correct series member.
When evacuating closed systems, the volume to be evacuated must be no more than 2 % of the nominal pumping capacity per hour. With 25 m³/h at 50 Hz this corresponds to a maximum closed volume of 0.5 m³; at 30 m³/h (60 Hz) the limit is 0.6 m³. Larger volumes require a different sizing approach or pump selection to avoid operating outside the intended use.
Exhaust lines must be sized and routed so that back pressure stays below +100 mbar. No filter may be installed on the exhaust air side. Excessive back pressure affects operation and can force oil out through the outlet.
The machine may only be operated set up horizontally with a maximum inclination of 1° in all directions. Mount on a plane, even floor able to carry the machine weight and secure it against tipping and falling; a tilted installation compromises oil circulation and lubrication.
Cooling air inlets and outlets must be at least 20 cm away from adjacent walls to prevent recirculation of hot cooling air and overheating. Provide at least 40 cm space around the machine for access to filter housing, oil filling point, oil sight glass, oil drain, gas ballast and oil separator housing.
Looking at the motor fan, the motor must rotate clockwise; check with a phase sequence indicator (anti-clockwise rotating field). Reverse rotation can draw in media and damage the machine, so the check must be completed before the pump is released for continuous duty.
After first start, stop the motor after 2 minutes and top oil up to the upper edge of the sight glass; repeat until all oil pipes are filled. The filling point must not be open while the pump is running. Thereafter check the oil level every day; low oil level can damage the pump, and visible oil mist in the exhaust air or leaks must be investigated immediately.
Oil viscosity must comply with ISO VG 100 as per DIN ISO 3448; the oil capacity is 1.0 l. Incorrect viscosity can cause overheating, insufficient pumping capacity or motor protection trips. The maintenance table in Chapter 7 covers oil change, oil separator insert, air filter cleaning and motor/coupling checks.
Selection & Integration Q&A
Pick the V-VCA 25 for fine-vacuum duty: continuous intake 0.5–130 mbar (abs.) at 50 Hz (0.5–100 mbar at 60 Hz), ultimate 0.5 mbar. Choose the V-VCE 25 for rough vacuum, 10–500 mbar (abs.) at 50 Hz. Both share identical construction and differ only in achievable vacuum.
Verify the motor data plate against the mains; unless stated otherwise, tolerances are ±5 % voltage and ±2 % frequency. Motors are IP 55, insulation class F per DIN EN 60034, so fit an appropriate motor protection switch. Confirm clockwise rotation at the motor fan with a phase sequence indicator before continuous operation. The electrical data in the specification table apply to the UA IE3 motor; confirm the actual motor variant (UA/GA/TA IE3) against the data plate.
Operate only horizontally with max. 1° inclination in all directions on a floor able to carry the weight, secured against tipping. Keep 20 cm clearance at cooling-air inlets/outlets and 40 cm around the machine for maintenance. Ambient and inlet temperature 5–40 °C; above 1000 m altitude output drops noticeably.
Plan for ISO VG 100 oil per DIN ISO 3448 (1.0 l capacity), topped up after the first 2 minutes of running and checked daily. The maintenance table also covers air filter cleaning, oil separator insert and oil change. Exhaust-side filters are not permitted; back pressure must stay below +100 mbar.