Elmo Rietschle V-VTN
Elmo Rietschle V-VTN — Central Industrial & Medical Vacuum Systems with Motor power 0.65 kW, Noise level 58 dB, Pumping speed 20.5 m³/h.
The V-VTN is a rotary vane vacuum pump configured with a G 1/2 suction port and R 1/2 exhaust silencer, available with IE3 motors from 0.55 to 1.5 kW. It delivers 17 m³/h at 50 Hz and 20.5 m³/h at 60 Hz, with noise levels of 58 dB and 61 dB respectively. This pump is intended for integration into central industrial vacuum systems where a compact, directly driven rotary vane stage is required.
Full specifications
| Motor power | 0.55 kW (50 Hz / GX IE3) 60 Hz / GX IE3: 0.63 kW · 50 Hz / GA IE3: 0.75 kW · 60 Hz / GA IE3: 0.9 kW · 50 Hz / GD IE3: 1.5 kW · 60 Hz / GD IE3: 1.8 kW · 50 Hz / 1~ 230 V: 0.55 kW · 60 Hz / 1~ 230 V: 0.65 kW |
| Noise level | 58 dB (50 Hz) 60 Hz: 61 dB |
| Pumping speed | 17 m³/hour (50 Hz) 60 Hz: 20.5 m³/hour |
| Rotational speed | 1463 rpm (50 Hz / GX IE3) 60 Hz / GX IE3: 1755 rpm · 50 Hz / GA IE3: 1445 rpm · 60 Hz / GA IE3: 1740 rpm · 50 Hz / GD IE3: 1450 rpm · 60 Hz / GD IE3: 1746 rpm · 50 Hz / 1~: 1450 rpm · 60 Hz / 1~: 1740 rpm |
| Exhaust silencer mfr | R 1/2 |
| Vacuum safety valve mfr | G 1/2 (01) |
| Vacuum regulation valve mfr | G 1/2 (02) |
| Screw cap mfr | G 1/2 |
| Nominal suction capacity mfr | 17 m3/h (50 Hz) |
| Nominal suction capacity mfr | 20.5 m3/h (60 Hz) |
| a1 mfr | 11 mm ((01) Standard version with vacuum safety valve) |
| a1 mfr | 29 mm ((02) Version with vacuum regulating valve) |
| b mfr | 254 mm |
| b1 mfr | 236 mm |
| c mfr | 283 mm |
| e mfr | 180 mm |
| f mfr | 220 mm |
| l mfr | 125 mm |
| l1 mfr | 60 mm |
| m mfr | 79 mm |
| n mfr | 106 mm ((01) Standard version with vacuum safety valve) |
| n mfr | 125 mm ((02) Version with vacuum regulating valve) |
| o mfr | 150 mm |
| p mfr | 170 mm |
| r mfr | 164 mm |
| r1 mfr | 11 mm |
| v mfr | 246 mm |
| v1 mfr | 16 mm |
| b1 (alt var) mfr | 236 mm |
| c (alt var) mfr | 283 mm |
| e (alt var) mfr | 180 mm |
| f (alt var) mfr | 220 mm |
| l (alt var) mfr | 125 mm |
| l1 (alt var) mfr | 60 mm |
| m (alt var) mfr | 79 mm |
| o (alt var) mfr | 150 mm |
| p (alt var) mfr | 170 mm |
| r (alt var) mfr | 164 mm |
| r1 (alt var) mfr | 11 mm |
| v (alt var) mfr | 246 mm |
| v1 (alt var) mfr | 16 mm |
| Weight | 29 kg (3~) 1~: 28 kg |
| Length | 254 mm GX IE3: 45 mm · GA IE3: 5 mm · GD IE3: 59 mm |
| max. Weight mfr | 28 kg (1~) |
| Total length a* mfr | 45 mm (GX IE3 0.55 kW) |
| Total length a* mfr | 5 mm (GA IE3 0.75 kW) |
| Total length a* mfr | 59 mm (GD IE3 1.5 kW) |
| Current | 2.4 / 1.4 A (50 Hz / GX IE3) 60 Hz / GX IE3: 2.5 / 1.45 A · 50 Hz / GA IE3: 2.98 / 1.72 A · 60 Hz / GA IE3: 3.01 / 1.74 A · 50 Hz / GD IE3: 6.0 / 3.45 A · 60 Hz / GD IE3: 6.0 / 3.45 A · 50 Hz / 1~: 3.9 A · 60 Hz / 1~: 4.4 A |
| Voltage | 230 / 400 V (50 Hz / GX IE3) 60 Hz / GX IE3: 230 / 460 V · 50 Hz / GA IE3: 230 / 400 V · 60 Hz / GA IE3: 230 / 460 V · 50 Hz / GD IE3: 230 / 400 V · 60 Hz / GD IE3: 230 / 460 V · 50 Hz / 1~: 230 V · 60 Hz / 1~: 230 V |
| Inlet connection | G 1/2 |
| Average noise level (EN ISO 3744) mfr | 58 dB (50 Hz) |
| Average noise level (EN ISO 3744) mfr | 61 dB (60 Hz) |
Description
The V-VTN is a directly driven rotary vane vacuum pump. Its suction connection is G 1/2, and the exhaust is fitted with an R 1/2 silencer. The pump is offered in two functional variants: standard version (01) with a vacuum safety valve (G 1/2) and version (02) with a vacuum regulating valve (G 1/2). Motor options include 3~ IE3 variants GX (0.55 kW at 50 Hz, 0.63 kW at 60 Hz), GA (0.75 kW at 50 Hz, 0.9 kW at 60 Hz), and GD (1.5 kW at 50 Hz, 1.8 kW at 60 Hz), as well as 1~ 230 V variants (0.55 kW at 50 Hz, 0.65 kW at 60 Hz). The overall length varies with motor: 45 mm for GX, 5 mm for GA, and 59 mm for GD. The pump weighs 28 kg with a 1~ motor and 29 kg with a 3~ motor. No sibling models are listed in the provided facts, so this description is limited to the V-VTN itself.
Integration & Operating Notes
3~ IE3 motors are dual-voltage (230/400 V at 50 Hz or 230/460 V at 60 Hz) and must be linked according to the supply voltage. 1~ motors are 230 V only. Connecting a 1~ motor to 400 V will destroy the winding. Check that the supply protection is rated for the starting current, which can be several times the full-load current.
Version (01) includes a vacuum safety valve that closes the suction port when the pump stops, preventing oil from being drawn into the vacuum chamber. If the process cannot tolerate any oil vapor, additional traps may be required. Version (02) with regulating valve does not provide this safety function unless specified.
The exhaust silencer (R 1/2) contains filter elements that become saturated with oil mist. Replace them according to the maintenance schedule in the manual to avoid increased back pressure and oil carryover. The vacuum safety valve (if fitted) should be inspected for proper sealing.
Starting the pump with the suction port completely closed can cause overheating and oil degradation. If the system includes a shut-off valve, ensure it is open before starting, or provide a bypass/regulating valve to limit ultimate pressure. The vacuum regulating valve (version 02) can serve this purpose.
Selection & Integration Q&A
Choose version (01) if the pump will be started and stopped frequently and you need to prevent oil backstreaming into the vacuum chamber. Choose version (02) if you need to adjust the ultimate vacuum or limit the suction pressure to match process requirements. Version (02) does not provide the safety shut-off function unless combined with additional controls.
The suction port is G 1/2 and the exhaust is R 1/2. Use piping rated for vacuum service and ensure all joints are leak-tight. The exhaust line must not be restricted; if necessary, pipe the exhaust to a safe location. The silencer is included, but additional exhaust filtration may be needed if oil mist is a concern.
The pump is designed for continuous duty, but ambient temperature and altitude affect cooling. Ensure adequate ventilation and do not exceed the maximum ambient temperature stated in the manual (typically 40°C). For higher altitudes or temperatures, derating may be required. Consult the manual for exact limits.
The base delivery includes the pump with motor and silencer, but not the vacuum safety valve or regulating valve unless specified. Spare parts such as vanes, filters, and gaskets are listed in the spare parts list E281 and must be ordered separately. A vacuum gauge or switch for monitoring is not included.