The BioBLU c is the single-use stirred-tank bioreactor variant of Eppendorf's BioBLU line, offered as a pre-sterilized, disposable vessel with an integrated impeller assembly. It is positioned within a portfolio spanning 60 mL to 500 L working volume, alongside the f and Stem Cell impeller variants. It serves as the cultivation vessel in upstream bioprocess systems, replacing clean-in-place glass or stainless vessels.
Full specifications
Description
Construction and series positioning
- BioBLU c is a single-use bioreactor: the cultivation vessel, impeller and headspace connections are supplied as a disposable assembly, eliminating cleaning and sterilization between runs.
- Within the BioBLU family it is the 'c' impeller configuration; sibling variants are the 'f' and Stem Cell impeller versions, which differ in mixing geometry rather than vessel format.
- The wider Eppendorf upstream portfolio places BioBLU vessels alongside reusable systems (DASbox, DASGIP, BioFlo 120/320 plus/720) covering 60 mL to 500 L working volume; the BioBLU c is the disposable option in that range.
Behavior and media
- No digitized curve points, matched performance specs or media data were supplied for this model, so gas-transfer rates, mixing times and power input cannot be stated here.
- The disposable bag/liner is the wetted surface; compatibility of the culture medium and any solvents with that film must be confirmed against the vessel's material documentation before use.
Control and operation
- The supplied brochure digest contains no sections on connections, sensors or control integration for this model; control is provided by the host bioreactor system and its software (DASware, BioCommand) rather than by the vessel itself.
- Installation, connection and operating specifics must be taken from the BioBLU c instruction manual, which was not among the supplied documents.
Integration & Operating Notes
No matched performance specifications or curve points were supplied for this model, so mass-transfer, mixing and power-input values needed for scale-up calculations are not available in this card and must be requested from the vessel documentation.
As a single-use vessel, the wetted flow path is discarded after the batch; the reusable hardware (drive, sensors, tubing connectors) is what carries the maintenance schedule, which is defined in the system manual rather than in the vessel documentation.
Selection & Integration Q&A
The c variant is the standard impeller configuration; the f and Stem Cell versions differ in impeller geometry for specific shear-sensitive or stem-cell cultures. Selection depends on the shear tolerance of the cells, and no comparative performance data for this model was supplied.
The vessel is controlled by an Eppendorf bioreactor system (BioFlo or DASGIP/DASbox class) running DASware or BioCommand software. Exact tubing, sensor and connector requirements are not in the supplied brochure digest and must be taken from the BioBLU c manual.
The disposable vessel and impeller assembly are consumed per batch; sensors, tubing, connectors and the drive/control hardware are separate items. The supplied brochure digest lists no included accessories, so the delivery scope must be confirmed on the quotation.