Eppendorf DASGIP ® Parallel Bioreactor System
Eppendorf DASGIP ® Parallel Bioreactor System — Bioreactors & fermenters.
The DASGIP Parallel Bioreactor System is a 16-unit parallel cell-culture and microbial bioreactor platform built around autoclavable glass or pre-sterilized single-use vessels of 1.5–2.3 L total volume. Each vessel is driven by a direct/magnetic overhead drive at 30–1250 rpm with pitched-blade impellers, TMFC gas mixing (overlay and/or sparger), and integrated heating/cooling in the DASGIP Bioblock. It is intended for parallel process development and scale-down studies where up to 16 independent runs must be controlled from one process computer.
Full specifications
| Application | Cell culture |
| Bacteria/yeast/fungi | yes |
| Drive | Direct/magnetic overhead drive |
| Exhaust Condensation | Water-cooled or liquid-free |
| Gas Supply | TMFC; overlay and/or sparger |
| Impellers | Pitched-blade |
| Insect | yes |
| Interchangeable Vessels | yes |
| Mammalian/animal | yes |
| Number Of Parallel Units | 16 unit |
| Software | DASware control, other DASware optional |
| Speed Ranges | 30...1250 rpm |
| Stem Cells | yes |
| Sterilization | Autoclavable/ pre-sterilized |
| Total Volume | 1.5...2.3 L |
| Validatable | no |
| Vessels | Glass/single-use vessels |
| Dimensions (W × D × H, 4-fold system without process computer) mfr | 140 x 70 x 53 cm (55 x 28 x 21 in) |
| Feed lines per vessel mfr | Up to 8 |
| pH control mfr | Acid and/or base, and other set-ups |
| DO control mfr | Cascade (O 2 concentration, gas flow rate), and |
| Level/foam mfr | Optional |
| OD measurement mfr | Optional (DASGIP OD4) |
| Exhaust analysis mfr | Optional (DASGIP GA4) |
| Typical Weight | 78 kg |
| Typical power consumption (4-fold system without process computer) mfr | 480 W (at 230 V)/ 432 W (at 115 V) (595 W/552 W |
| User Interface | Process computer with monitor |
| Standard Feed Rates (depending On Tube Diameter) | 0.3...9.5 L/h |
| Standard Gas Flow Rates | 0.1...50 |
| Standard Gas Mixing | 2 |
| Standard temperature range (at 25° C room temp.) mfr | 5 K above cooling agent temperature – 99°C (DASG |
Description
Architecture and positioning
- The system is a 16-fold parallel platform; the brochure scope covers 4-, 8-, 16- and 24-fold DASGIP and DASbox configurations, with or without Bioblock, in standard (CC) and single-use (CCSU) variants. This card describes the 16-unit DASGIP configuration with glass/single-use vessels of 1.5–2.3 L total volume.
- Vessels are interchangeable and either autoclavable glass or pre-sterilized single-use. Temperature control is integrated in the DASGIP Bioblock (heating and cooling), with additional cooling fingers optional.
- The 4-fold system without process computer measures 140 × 70 × 53 cm and weighs 78 kg; the 16-fold frame is larger and is not dimensioned in the supplied facts.
Behavior under load and in different media
- Agitation spans 30–1250 rpm with pitched-blade impellers on a direct/magnetic overhead drive; the same drive covers cell culture (mammalian, stem, insect) and microbial hosts (bacteria, yeast, fungi).
- Gas supply uses thermal mass flow controllers (TMFC) with overlay and/or sparger; standard gas flow rates are 0.1–50 (unit as printed) and standard gas mixing provides 2 gas channels.
- Feed lines: up to 8 per vessel; standard feed rates depend on tube diameter and span 0.3–9.5 L/h.
- pH is controlled by acid and/or base addition (other set-ups possible); DO is controlled by cascade on O2 concentration and gas flow rate. ORP is not provided. Level/foam, OD (DASGIP OD4) and exhaust analysis (DASGIP GA4) are optional.
- Exhaust condensation is water-cooled or liquid-free.
Control, installation and operation
- The user interface is a process computer with monitor running DASware control; other DASware modules are optional. Nominal power is 480 W.
- Standard temperature range at 25 °C room temperature is 5 K above the cooling-agent temperature up to 99 °C (DASGIP Bioblock).
- The system is stated as not validatable. No certificates or application notes were supplied.
Integration & Operating Notes
The nominal power of 480 W is stated for the system. When sizing the laboratory circuit and UPS, account for the process computer and monitor in addition to the bioreactor frame, and confirm the supply voltage from the nameplate since the supplied facts do not state it.
Standard feed rates of 0.3–9.5 L/h depend on the tube diameter, so the peristaltic pump tubing must be selected against the required feed rate before the run. Up to 8 feed lines per vessel are available, allowing separate acid, base and nutrient streams.
OD measurement (DASGIP OD4), exhaust analysis (DASGIP GA4) and level/foam detection are optional and not part of the base delivery. Specify them at order time if biomass or off-gas data are required, because they add sensors and interfaces to each vessel.
Glass vessels are autoclavable and single-use vessels are pre-sterilized; the choice determines the sterilization workflow and the consumable list. The supplied facts contain no calibration or service-interval schedule, so intervals must be taken from the DASGIP operating manual.
Selection & Integration Q&A
Choose 16-fold DASGIP when 1.5–2.3 L vessels and up to 16 parallel runs are needed for process development. DASbox covers 60–250 mL working volume for smaller scale-down; 4- and 8-fold DASGIP frames suit lower throughput with the same vessel size.
TMFC gas supply with overlay and/or sparger at 0.1–50 standard gas flow, up to 8 feed lines per vessel with tubing sized for 0.3–9.5 L/h, and a cooling agent cold enough that the setpoint stays at least 5 K above it up to 99 °C.
OD4 measurement, GA4 exhaust analysis, level/foam detection and additional cooling fingers are optional. Glass versus single-use vessels are a configuration choice, and the supplied facts list no cables or calibration kits, so these must be confirmed against the order configuration.