Eppendorf MiniSpin ® / MiniSpin ® plus - Mini Centrifuge
Eppendorf MiniSpin ® / MiniSpin ® plus - Mini Centrifuge — Centrifuges.
The MiniSpin/MiniSpin plus is a non-refrigerated microcentrifuge with a fixed-angle rotor, reaching 13,400 rpm and 12,100 × g. It accepts up to 12 × 1.5/2.0 mL tubes and is suited to rapid pelleting and spin-down steps in molecular biology workflows.
Full specifications
| Acceleration Time 1) | 13 s |
| Deceleration Time 1) | 12 s |
| Dimensions (w × D × H) | 22,5 × 23,0 × 13,0 cm |
| Max. Rcf | 12100 g |
| Max. Rcf With Fixed-angle Rotor | 12100 g |
| Rotational speed | 800...13400 rpm |
| Rotors available mfr | 2 |
| Max. capacity mfr | 12 × 1.5/2.0 mL |
| Timer mfr | 15 s – 30 min |
| Height (with Open Lid) | 25 cm |
| Product Weight | 3.7 kg |
| Max. Power Consumption | 70 W |
| Voltage | 230 V |
| Power Plug | power plug type F |
| Cooling | non-refrigerated |
| Noise level | 49 dB |
Description
Construction and positioning
- The MiniSpin/MiniSpin plus is a compact, non-refrigerated microcentrifuge with a footprint of 22.5 × 23.0 cm and a height of 13.0 cm (25 cm with the lid open).
- It uses a fixed-angle rotor and supports two rotor options, with a maximum capacity of 12 × 1.5/2.0 mL tubes.
- The unit weighs 3.7 kg and is powered by a 70 W motor from a 230 V supply via a type F power plug.
Performance and operation
- Rotational speed is adjustable from 800 to 13,400 rpm, corresponding to a maximum RCF of 12,100 × g with the fixed-angle rotor.
- Acceleration to set speed takes 13 s and deceleration takes 12 s, supporting short spin cycles.
- The timer covers 15 s to 30 min, and the noise level is 49 dB during operation.
Integration and control
- The brochure lists compatible rotors and adapters (e.g., F-45-24-11, FA-24x2, FA-24x2-PTFE) for different tube formats, but no control interface or communication details are provided in the supplied facts.
- Installation requires a 230 V supply with a type F outlet; no additional electrical specifications are given.
Integration & Operating Notes
The maximum RCF of 12,100 × g applies to the fixed-angle rotor configuration. Operating above this limit or with unapproved rotor/adaptor combinations may compromise tube integrity and rotor safety; always confirm the rotor and adapter rating before setting the speed.
The brochure lists multiple rotor and adapter part numbers (e.g., F-45-24-11, FA-24x2, FA-24x2-PTFE). Regularly check these components for cracks, corrosion, or deformation, and replace them as needed to maintain safe operation; no specific service interval is provided in the supplied facts.
Selection & Integration Q&A
Choose this model for non-refrigerated, routine spin-downs up to 12,100 × g and 12 × 1.5/2.0 mL tubes. For temperature-sensitive samples or higher capacity, consider refrigerated models such as the 5418 R or 5425 R, which are outside this model's scope.
Two rotors are available, including fixed-angle types. The maximum capacity is 12 × 1.5/2.0 mL. The brochure lists adapters such as FA-24x2 and FA-24x2-PTFE for different tube formats; select the rotor and adapter combination that matches your tube size and required RCF.
Regularly inspect rotors and adapters for wear; replacement parts are listed in the brochure (e.g., F-45-24-11, FA-24x2). No specific maintenance interval is given. Accessories such as additional rotors or adapters are not included in the base delivery and must be ordered separately.