Eppendorf New Brunswick Innova ® 40/40R - Benchtop Orbital Shaker
Eppendorf New Brunswick Innova ® 40/40R - Benchtop Orbital Shaker — Laboratory shakers.
Benchtop orbital incubator shaker with a triple-eccentric counterbalanced drive and a 46 cm platform, available in refrigerated (40R) and non-refrigerated (40) versions. The 40R holds 15–80 °C with 0.25 °C uniformity and runs 25–500 rpm depending on load. It serves as a stand-alone benchtop incubation and shaking station for cultures and assays.
Full specifications
| Audible And Visual Alarms | yes |
| Available Program Modes | -232 |
| Benchtop (b), Under Bench (u), Floor (f) Or Stackable (s) | B |
| Dimensions (w × D × H) | 55,9 × 76,2 × 61 cm |
| Door Opening | top opening hood |
| Drive Mechanism | triple-eccentric counterbalanced drive |
| Memory | non volatile with automatic power failure restart |
| Motor Type | Solid state, DC brushless motor |
| Multi-step Programming | yes |
| Platform Size (cm/in) | 46 cm |
| Programming Steps / Storable Programs | 15 |
| Refrigerated | yes |
| Remote Device Monitoring And Notifications (visionize ® ) | VisioNize ® box enabled |
| Slide-out Platform | no |
| Temperature range | 15...80 °C |
| Temperature uniformity | 0.25 °C |
| Timer | 0.01 – 99.59 h |
| Speed range mfr | 25 up to 500 rpm (depending on load) |
| Steps per program mfr | 15 |
| Stored programs mfr | 4 |
| Capacity mfr | medium |
| External Height (with Lid/door Open) | 101.6 cm |
| Product Weight | 79.4 kg |
| Voltage | 230 V |
| Power Plug | type F/type I |
| Cetlus And Ce Marked | yes |
Description
Construction and positioning
- Benchtop (B) unit with a top-opening hood; the 40R is the refrigerated member of the Innova 40/40R pair, adding active cooling down to 15 °C where the non-refrigerated 40 relies on ambient conditions.
- Triple-eccentric counterbalanced drive on a 46 cm platform, driven by a solid-state DC brushless motor.
- External dimensions 55.9 × 76.2 × 61 cm (W × D × H); height with lid open 101.6 cm; product weight 79.4 kg.
Behavior and operating envelope
- Speed range 25–500 rpm, the upper limit depending on load; temperature range 15–80 °C with 0.25 °C uniformity.
- Timer 0.01–99.59 h plus continuous operation; multi-step programming with 15 steps per program and 4 stored programs.
- Non-volatile memory with automatic power-failure restart; audible and visual alarms.
Control, connection and operation
- 230 V supply with type F/type I power plug; CE and cETLus marked.
- VisioNize box enabled for remote device monitoring and notifications.
- The platform does not slide out; vessels are loaded from the top through the hood.
Integration & Operating Notes
The lid swings to an external height of 101.6 cm, so benchtop or under-shelf placement must leave that clearance above the 61 cm cabinet; the unit is benchtop-only (not stackable or under-bench) and weighs 79.4 kg, so the bench must carry that load.
The unit is specified at 230 V and ships with a type F/type I power plug; confirm the site socket and circuit match before installation, since the plug type is fixed at delivery and no other voltage is stated for this model.
The 25–500 rpm range is load-dependent: the 500 rpm ceiling applies only within the load the drive can counterbalance, so heavy or unevenly distributed vessel loads reduce the achievable maximum speed and must be planned for in protocol design.
Non-volatile memory with automatic power-failure restart means the shaker returns to its programmed run after a mains interruption; account for this when the process must not resume unattended, and use the audible/visual alarms to detect fault states.
Remote device monitoring and notifications are provided through the VisioNize box; the box and its connectivity are a separate item from the shaker itself, so specify it explicitly if remote alarm and status visibility are required.
Selection & Integration Q&A
Pick the 40R when you need controlled temperatures below ambient down to 15 °C; the non-refrigerated 40 cannot cool. Both share the 46 cm platform, 25–500 rpm load-dependent range and 15-step programming, so the choice is purely the cooling requirement.
A 230 V supply with a matching type F or type I socket; the plug type is fixed at delivery. For remote monitoring and notifications, a VisioNize box must be specified separately, as it is not part of the base shaker.
It is benchtop-only and needs 101.6 cm clear height for the open hood above the 61 cm cabinet, so a low shelf blocks loading. The 79.4 kg unit needs a bench rated for it, and the 500 rpm ceiling applies only within the load the counterbalanced drive can handle.
The base unit ships without the VisioNize box for remote monitoring; specify it if needed. No service intervals are stated in the supplied documents, so maintenance scheduling must come from the operating manual rather than this card.