Labconco Kjeldahl Distillation Apparatus
Labconco Kjeldahl Distillation Apparatus — Kjeldahl & extraction apparatus.
The Labconco Kjeldahl Distillation Apparatus is a steam-distillation unit for ammonia determination in digested samples. This 18-place configuration is the largest hooded combination variant in the series, integrating digestion and distillation in one bench unit. It serves laboratories running high-throughput nitrogen/protein analysis where fume containment and multi-sample parallelism are required.
Full specifications
| Number of places mfr | 18 places |
| CFM mfr | 1000 CFM |
| Electrical requirements mfr | 115 phase |
| Shipping weight mfr | 361 lbs |
| Amps mfr | 32 A |
| KW mfr | 21 kW |
Description
Series positioning and construction
- The Labconco Kjeldahl line spans Classical Macro (open and hooded combination units, digestion units, distillation units), Micro (Micro Digestors, RapidStill I), and Rapid (Rapid Digestors, RapidStill II) families.
- This model is the 18-place hooded combination configuration — the highest place count in the hooded combination group (siblings are 6- and 12-place hooded units and 6-/12-place open units).
- Hooded construction encloses the digestion/distillation zone for fume capture; open units in the same series lack this enclosure and rely on external ventilation.
Capacity and utility envelope
- 18 simultaneous places; electrical service at 32 A and 21 kW; ventilation demand 1000 CFM; shipping weight 361 lbs.
- These figures describe the unit as configured; no per-place scaling or turndown data is provided in the source.
Operation
- The catalog excerpt provides ordering information only; no control logic, temperature program, or distillation cycle details are documented in the available digests. Operating specifics must be taken from the unit's instruction manual, not inferred here.
Integration & Operating Notes
The unit draws 32 A at 21 kW, which exceeds typical 20 A bench circuits. A dedicated branch with correctly sized conductors and overcurrent protection must be confirmed before installation; sharing the circuit with other laboratory equipment risks nuisance tripping during simultaneous heating of all 18 places.
The hooded configuration requires 1000 CFM of ventilation to capture digestion fumes. The laboratory exhaust system must be sized for this airflow at the unit's location, and duct routing/static pressure should be checked so the hood face velocity is maintained when the unit is in operation.
Selection & Integration Q&A
Choose the 18-place unit when batch throughput justifies the 32 A / 21 kW service and 1000 CFM exhaust. The 6- and 12-place hooded units fit smaller workloads and lower utility capacity; the open combination units suit labs with existing fume-hood space instead of an integrated hood.
A dedicated 32 A, 21 kW electrical supply and an exhaust system capable of 1000 CFM at the unit's hood. Confirm panel spare capacity, conductor sizing, and duct static pressure before delivery; the catalog excerpt lists no other interface requirements.
The catalog excerpt covers ordering tables only and does not list included accessories, spare parts, or service intervals. Reagent/steam components, glassware, and exhaust connections should be confirmed against the unit's instruction manual and order configuration before purchase.