Nabertherm HT 160/17
Nabertherm HT 160/17 — High-temperature furnaces.
The HT 160/17 is a 160-litre high-temperature chamber furnace with molybdenum disilicide heating elements and fiber insulation, rated to 1750 °C on a 3-phase supply. Within the HT ../17 series it is the mid-capacity modification between the 64-litre and 450-litre units, sized for batch sintering, annealing and melting work that needs a large uniform hot zone rather than the smallest possible chamber.
Nabertherm HT Series — Model Comparison & Selection
| Model | Chamber volume, L | Electrical connection | Weight, kg | Max temperature, °C |
|---|---|---|---|---|
| HT 160/17 Current | 160 | 3-phase | 760 | 1750 |
| HT 08/17 | 8 | 3-phase2 | 215 | 1750 |
Full specifications
| Chamber volume | 160 l |
| Chamber volume | 160 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Connected mfr | 21.5 |
| Inner dimensions (W × D × H) mfr | 500 × 550 × 550 mm |
| Outer dimensions (W × D × H) mfr | 1250 × 1040 × 2260 mm |
| Weight | 760 kg |
| Weight | 760 kg |
| Max temperature | 1750 °C |
| Max temperature | 1750 °C |
Description
Construction and series position
The HT 160/17 is a chamber furnace of the HT ../17 family, which uses molybdenum disilicide (MoSi2) heating elements in a fiber-insulated chamber. Its 160-litre working volume (500 × 550 × 550 mm inner dimensions) places it between the HT 64/17 and the larger HT 450/16 in the sibling set; the HT 08/17 and HT 29/17 cover small-charge work. The outer envelope is 1250 × 1040 × 2260 mm at 760 kg, so the unit is floor-standing and requires a dedicated installation footprint rather than a bench.
Thermal behavior and media
Maximum temperature is 1750 °C, and the MoSi2 element type is what permits operation in air at this level; no protective or reducing atmosphere capability is stated in the verified facts, so process atmospheres must not be assumed. No digitized heating or cooling curves were supplied for this model, so no ramp rates are quoted here. Chamber uniformity and control behavior depend on the controller and instrumentation options described in the process-control documentation, not on the furnace body alone.
Electrical and control architecture
The furnace is a 3-phase unit; the factory sheet lists a connected value of 21.5 without a unit, so the electrical load must be confirmed against the nameplate before sizing the supply. Control is external to the furnace body: the Nabertherm 500-series controllers and the MyNabertherm app are the documented control layer, and temperature-uniformity instrumentation per AMS2750F is available as an option. Recorders and additional controller options are separate items.
Operation
No installation, connection or operating instructions specific to the HT 160/17 appear in the attached document digests; those digests cover controllers, fiber-optics glass production, foundry furnaces and dental furnaces. Installation and operating detail must therefore come from the furnace's own manual, which was not among the supplied documents.
Integration & Operating Notes
The furnace body carries no integrated programmer in the verified facts. The 500-series controllers, MyNabertherm app connectivity, AMS2750F uniformity instrumentation and recorder options are documented separately and must be ordered and wired as part of the control cabinet design.
Molybdenum disilicide elements change resistance with service life, so replacement practice and interval must follow the furnace manual. No element life, inspection interval or spare-parts list is included in the verified facts or the attached digests; these must be obtained from Nabertherm documentation for the HT 160/17.
Selection & Integration Q&A
Pick the 160/17 when the batch needs a 500 × 550 × 550 mm hot zone at up to 1750 °C. The HT 64/17 suits smaller charges; the HT 450/16 is the large-chamber option but is rated to 1600 °C, so it cannot replace the 1750 °C capability.
A 3-phase feed sized from the nameplate (the sheet's 21.5 connected figure is unlabeled), plus a separate controller from the Nabertherm 500 series or equivalent, with recorder and AMS2750F uniformity instrumentation as options. None of these are part of the furnace body.
MoSi2 heating elements, thermocouples, controller, recorder and any AMS2750F instrumentation are separate items. Element replacement intervals and spare-part numbers are not stated in the verified facts or attached digests; request the HT 160/17 service documentation from Nabertherm.