Nabertherm LH 120/13
Nabertherm LH 120/13 — Laboratory.
The LH 120/13 is a brick-insulated chamber furnace with a 120-litre square chamber (500 × 500 × 500 mm) rated to 1300 °C, wired for 3-phase supply at 15 kW connected load. Within the LH series it is the 120-litre, 1300 °C modification, distinguished from the LH 120/12 sibling by its higher maximum temperature. It serves laboratory heat-treatment and firing duties where a cubic, uniformly heated workspace up to 1300 °C is required.
Nabertherm Chamber Furnaces with Brick Insulation or Fiber Insulation | Nabertherm Series — Model Comparison & Selection
Full specifications
| Chamber volume | 120 l |
| Electrical connection | 3-phase |
| Connected mfr | 15 |
| Inner dimensions (W × D × H) mfr | 500 × 500 × 500 mm |
| Outer dimensions (W × D × H) mfr | 890 × 1180 × 1470 mm |
| Weight | 410 kg |
| Max temperature | 1300 °C |
Description
Construction and series positioning
- Brick-insulated chamber furnace, 120 l working volume, inner chamber 500 × 500 × 500 mm (W × D × H), outer envelope 890 × 1180 × 1470 mm, unit weight 410 kg.
- Maximum working temperature 1300 °C; the sibling LH 120/12 shares the 120-litre chamber but is limited to 1200 °C, so the /13 is selected when the process needs the extra 100 °C ceiling.
- Electrical connection is 3-phase with a connected load of 15 kW; the supply voltage is not stated in the verified data and must be confirmed against the nameplate before installation.
Thermal behaviour
- No digitized heating or cooling curves are available for this model, so no heating-rate or uniformity figures are asserted here; chamber uniformity and achievable ramp rates depend on the controller and load configuration chosen at order.
- The 1300 °C rating defines the process window; the 120-litre cubic chamber suits batch loads that fit within 500 mm in each axis.
Control and documentation context
- The attached controller documentation covers the Nabertherm 500-series controllers and the MyNabertherm app, including process-data storage and AMS2750F instrumentation types; it does not print model-specific wiring for the LH 120/13.
- The remaining attached digests (fiber-optics glass, foundry, dental) describe other product lines and contain no LH 120/13-specific installation facts; installation and operating instructions for this furnace must be obtained separately.
Integration & Operating Notes
The verified data state only a 3-phase connection and 15 kW connected load; the operating voltage is not given. The electrician must read the furnace nameplate and size the feeder, fusing and disconnector for the actual voltage and current, since connecting a 3-phase furnace to the wrong voltage risks element damage.
The 1300 °C maximum is the ceiling for this modification; the sibling LH 120/12 is rated only to 1200 °C, so process recipes written for the /12 can run hotter here but any setpoint above 1300 °C is outside the furnace rating and will shorten element and insulation life.
The controller documentation describes 500-series controllers, MyNabertherm app connectivity, process-data storage and AMS2750F instrumentation types as configurable options. The base furnace delivery does not establish which controller, recorder or interface is fitted; this must be fixed at order.
None of the attached document digests covers the LH chamber furnace line, so element inspection, thermocouple replacement and insulation checks cannot be scheduled from them. Request the model-specific operating and maintenance instructions from Nabertherm before commissioning.
Selection & Integration Q&A
Pick the LH 120/13 when the process needs up to 1300 °C in a 120-litre, 500 mm cubic chamber. The LH 120/12 gives the same volume but only 1200 °C; the LF 60/14 is a 60-litre, 1400 °C fiber-insulated unit, so choose it only if higher temperature matters more than chamber size.
The furnace is a 3-phase, 15 kW load, but the verified data do not state the operating voltage. Size the feeder, fusing and main disconnector from the nameplate voltage and current, and provide a dedicated circuit; do not assume a voltage from the model code.
The verified data list only the furnace itself: 120 l chamber, 1300 °C rating, 3-phase 15 kW connection. Controller type, recorder, MyNabertherm connectivity, thermocouples and any AMS2750F instrumentation are option selections described in the controller documentation, not confirmed base-delivery items.