Nabertherm LS 25/13
Nabertherm ·Made in Germany · In Active Production

Nabertherm LS 25/13

Nabertherm LS 25/13 — Special application furnaces.

The LS 25/13 is a fast-firing furnace with a 25-litre chamber (500 × 500 × 100 mm) rated to 1300 °C, connected via a 3-phase supply. Its very low 100 mm chamber height distinguishes it within the series, suiting flat, wide loads that require rapid heating rather than tall batch stacking.

Full specifications

Core Performance & Functional Specifications
Chamber volume 25 l
Electrical connection 3-phase1
Connected mfr 22
Inner dimensions (W × D × H) mfr 500 × 500 × 100 mm
Outer dimensions (W × D × H) mfr 900 × 1030 × 1150 mm
Dimensions, Weight & Mechanical Design
Weight 160 kg
Operating Conditions, Environment & Protection
Max temperature 1300 °C

Description

Construction and series positioning

The LS 25/13 is a special-application furnace built around a 25-litre chamber measuring 500 mm wide × 500 mm deep × only 100 mm high. The shallow chamber geometry is the defining architectural feature: it favours large, flat workpieces and uniform exposure over vertical stacking. The outer envelope is 900 × 1030 × 1150 mm and the unit weighs 160 kg. Electrical connection is 3-phase; the extra specification lists a connected value of 22 without a printed unit, so the load figure should be confirmed against the nameplate before sizing supply cabling.

Thermal behaviour

Maximum working temperature is 1300 °C. No digitized heating or cooling curves were supplied for this model, so no heat-up or recovery rates are stated here. The combination of a 1300 °C ceiling and a 100 mm chamber height means the usable working volume is a wide, thin slab; process planning should treat the 25 litres as a flat envelope rather than a cube.

Control and documentation context

The attached controller digest covers the Nabertherm 500-series controllers and the MyNabertherm app, including process-data storage and temperature-uniformity instrumentation types (AMS2750F). It does not print model-specific wiring or setpoints, so controller configuration must be taken from the furnace's own wiring diagram. The fiber-optics catalog section describes LS safety technology per EN 1539 only for TR and KTR oven models; that attribution must not be transferred to this furnace without confirmation from Nabertherm.

Integration & Operating Notes

Electrical
Confirm the 22 connected-load figure and its unit before cabling

The extra specification gives a connected value of 22 with no unit printed, while the matched spec only states 3-phase connection. Supply protection, cable cross-section and isolator rating must be sized from the nameplate rating, not from this card, because an assumed unit (A or kW) could undersize the feed.

Factory Specification Sheet
Process Limits
Treat the 25-litre volume as a flat 500 × 500 × 100 mm envelope

The chamber is only 100 mm high, so tall crucibles, stacked boats or vertically fixtured parts will not fit even though the nominal volume is 25 litres. Process recipes and fixture design must be validated against the 500 × 500 mm floor plan and the 1300 °C ceiling before committing a load.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the LS 25/13 rather than another furnace in the fast-firing range?

Choose it for flat, wide charges that fit the 500 × 500 × 100 mm chamber and need up to 1300 °C. If the load is tall or stacked, the 100 mm height rules this model out regardless of its 25-litre nominal volume; a taller chamber is then required.

What supply and protection does the 3-phase connection require?

The unit is 3-phase, and the extra specification lists a connected value of 22 without a printed unit. Size the feeder, breaker and isolator from the nameplate rating on the delivered unit, not from this card, and verify phase rotation before first start.

What maintenance and accessories are not included in the base delivery?

The supplied documents list no maintenance schedule, error codes or consumables for this model, and no cables, recorders or app hardware are stated as included. Obtain the service interval, thermocouple and element spares, and any recorder or controller options from the furnace manual and order confirmation.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF