Nabertherm N 300/G
Nabertherm ·Made in Germany · In Active Production

Nabertherm N 300/G

Nabertherm N 300/G — Forced Convection.

The N 300/G is a brick-insulated chamber furnace with a 300-litre working volume (550 × 700 × 780 mm) and a maximum temperature of 900 °C, built for cooling and relieving stresses in glass. It is the smaller-volume unit in the series, positioned alongside the N 500/GS and N 660/G, and is intended for batch heat-treatment cycles where the load is heated and then controlled-cooled.

Nabertherm Brick-Insulated Chamber Furnaces for Cooling/Relieving Stresses in Glass | Nabertherm Series — Model Comparison & Selection

Model Chamber volume, LHeating power, WWeight, kgElectrical connectionMax temperature, °C
N 300/G Current 300154503-phase900
N 660/G 660269503-phase900

Full specifications

Core Performance & Functional Specifications
Chamber volume 300 l
Electrical connection 3-phase
Heating power 15 watt
Inner dimensions (W × D × H) mfr 550 × 700 × 780 mm
Outer dimensions (W × D × H) mfr 870 × 1300 × 1760 mm
Dimensions, Weight & Mechanical Design
Weight 450 kg
Operating Conditions, Environment & Protection
Max temperature 900 °C

Description

Construction and series positioning

Electrical and thermal behaviour

Control and documentation

Integration & Operating Notes

Electrical
Verify connected load on the nameplate before supply sizing

The matched spec records a 3-phase connection but the heating-power field reads 15 watt, which cannot be correct for a 300 l furnace at 900 °C. Do not size cables, contactors or fuses from that field; read the actual kW and full-load current from the unit nameplate or the model-specific wiring diagram.

Factory Specification Sheet
Process Limits
Keep the charge within the 550 × 700 × 780 mm chamber

The working volume is defined by the inner dimensions; glass loads that touch the heating elements or the chamber walls will see local overheating and non-uniform stress relief. Basket or support furniture must be sized to leave a gap to the walls and door.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the N 300/G rather than the N 500/GS or N 660/G?

Pick the N 300/G when the glass batch fits the 550 × 700 × 780 mm chamber and the 300 l volume; the N 500/GS and N 660/G are larger siblings for bigger charges. Over-sizing wastes chamber volume and makes temperature uniformity harder to hold at part load.

What supply and protection does the N 300/G need?

It is a 3-phase unit, but the recorded 15 watt heating-power field is not usable for sizing. Take the connected load and full-load current from the nameplate or model-specific wiring diagram, then size the feeder, disconnect and overcurrent protection from those values.

What is supplied with the N 300/G and what must be ordered separately?

The verified facts list no accessories, cables, recorder or controller in base delivery. The controller digest covers 500-series controllers and the MyNabertherm app as separate items, so specify controller, recorder and any charge furniture explicitly; no maintenance interval is stated in the supplied documents.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF