Nabertherm N 300/G
Nabertherm N 300/G — Forced Convection.
The N 300/G is a brick-insulated chamber furnace with a 300-litre working volume (550 × 700 × 780 mm) and a maximum temperature of 900 °C, built for cooling and relieving stresses in glass. It is the smaller-volume unit in the series, positioned alongside the N 500/GS and N 660/G, and is intended for batch heat-treatment cycles where the load is heated and then controlled-cooled.
Nabertherm Brick-Insulated Chamber Furnaces for Cooling/Relieving Stresses in Glass | Nabertherm Series — Model Comparison & Selection
| Model | Chamber volume, L | Heating power, W | Weight, kg | Electrical connection | Max temperature, °C |
|---|---|---|---|---|---|
| N 300/G Current | 300 | 15 | 450 | 3-phase | 900 |
| N 660/G | 660 | 26 | 950 | 3-phase | 900 |
Full specifications
| Chamber volume | 300 l |
| Electrical connection | 3-phase |
| Heating power | 15 watt |
| Inner dimensions (W × D × H) mfr | 550 × 700 × 780 mm |
| Outer dimensions (W × D × H) mfr | 870 × 1300 × 1760 mm |
| Weight | 450 kg |
| Max temperature | 900 °C |
Description
Construction and series positioning
- Brick-insulated chamber with a 300 l working volume; inner dimensions 550 × 700 × 780 mm (W × D × H), outer dimensions 870 × 1300 × 1760 mm.
- Maximum temperature 900 °C, which places it in the forced-convection chamber furnace class used for glass stress relief rather than high-temperature sintering.
- Within the series, the N 300/G is the smaller-volume alternative to the N 500/GS and N 660/G; choose it when the batch fits the 550 × 700 × 780 mm chamber and the larger siblings would be underloaded.
Electrical and thermal behaviour
- The matched electrical spec lists a 3-phase connection; the heating-power field is recorded as “15 watt”, which is not physically consistent with a 300 l furnace and is therefore not restated here as a rating. Confirm the actual connected load from the nameplate before sizing the supply.
- No digitized curve points were supplied, so no heat-up or cooling-rate behaviour is asserted; the 900 °C ceiling is the only verified thermal limit.
Control and documentation
- The attached controller digest covers the Nabertherm 500-series controllers and the MyNabertherm app, including process-data storage and AMS2750F instrumentation types; it does not print furnace-specific wiring or model codes.
- The other attached digests (fiber-optics glass, foundry, dental) describe other product lines and contain no N 300/G-specific installation facts.
Integration & Operating Notes
The matched spec records a 3-phase connection but the heating-power field reads 15 watt, which cannot be correct for a 300 l furnace at 900 °C. Do not size cables, contactors or fuses from that field; read the actual kW and full-load current from the unit nameplate or the model-specific wiring diagram.
The working volume is defined by the inner dimensions; glass loads that touch the heating elements or the chamber walls will see local overheating and non-uniform stress relief. Basket or support furniture must be sized to leave a gap to the walls and door.
Selection & Integration Q&A
Pick the N 300/G when the glass batch fits the 550 × 700 × 780 mm chamber and the 300 l volume; the N 500/GS and N 660/G are larger siblings for bigger charges. Over-sizing wastes chamber volume and makes temperature uniformity harder to hold at part load.
It is a 3-phase unit, but the recorded 15 watt heating-power field is not usable for sizing. Take the connected load and full-load current from the nameplate or model-specific wiring diagram, then size the feeder, disconnect and overcurrent protection from those values.
The verified facts list no accessories, cables, recorder or controller in base delivery. The controller digest covers 500-series controllers and the MyNabertherm app as separate items, so specify controller, recorder and any charge furniture explicitly; no maintenance interval is stated in the supplied documents.