Nabertherm NA 120/45 LS
Nabertherm ·Made in Germany · In Active Production

Nabertherm NA 120/45 LS

Nabertherm NA 120/45 LS — Prozesse Unter Luft.

The NA 120/45 LS is a forced-convection chamber furnace with a 120-litre chamber (450 × 600 × 450 mm) and a maximum operating temperature of 450 °C, built to EN 1539 safety technology for processes under air with solvent release. It is the 120-litre modification of the NA/LS series, distinguished by its exhaust air flow rate of 100–120 and solvent-volume limits that scale with temperature. It is used for drying, curing and heat treatment where flammable volatiles must be safely removed from the work chamber.

Full specifications

Core Performance & Functional Specifications
Chamber volume 120 l
Heating power 18 watt
Exhaust air flow rate mfr 100 - 120
Inner dimensions (W × D × H) mfr 450 × 600 × 450 mm
Outer dimensions (W × D × H) mfr 1250 × 1550 × 1950 mm
Operating Conditions, Environment & Protection
Max temperature 450 °C

Description

Construction and positioning

Behaviour under load and media

Installation, control and operation

Integration & Operating Notes

Process Limits
Solvent charge must follow the temperature-dependent volume table

The source lists five maximum solvent volumes (51, 20, 9, 5 and 4) under one label without the corresponding temperature steps. Before any solvent-bearing load is introduced, the applicable volume for the actual setpoint must be confirmed from the EN 1539 documentation; exceeding the limit for that temperature risks an explosive atmosphere in the chamber.

Factory Specification Sheet, extra specifications

Selection & Integration Q&A

When should I choose the NA 120/45 LS rather than another size in the NA/LS forced-convection chamber furnace series?

Choose the NA 120/45 LS when the workload fits the 450 × 600 × 450 mm chamber and the process needs EN 1539 safety technology at up to 450 °C with solvent release. Larger series members (up to 500 l) are for bigger batches; the 120-litre chamber is the deciding factor here.

What must be verified in the exhaust and fresh-air path before connecting this furnace?

The exhaust air flow rate must be held at 100–120 (unit not stated) whenever solvents are present. Ducting, extraction fan and any monitoring devices must be sized to maintain that flow, and the solvent charge must stay within the temperature-dependent volume limits.

What maintenance and accessory information is available for this model in the supplied documents?

None specific: the controller digest covers the 500 series and MyNabertherm app generically, and the other brochures do not address the NA 120/45 LS. Maintenance intervals, error codes and optional cables or recorders must be confirmed from the furnace instruction manual and order documentation.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF