Nabertherm NA 500/85
Nabertherm NA 500/85 — Furnaces Protective Gas Boxes.
The NA 500/85 is a forced-convection chamber furnace with a 500 l chamber (750 × 1000 × 750 mm) rated to 850 °C, electrically heated and connected via 3-phase supply. Within the NA series it is the 500-litre, 850 °C modification, distinguished from the NA 500/45 by its higher maximum temperature and from the NA 250/85 by its larger chamber. It serves as a batch heat-treatment unit for processes requiring uniform forced-air circulation up to 850 °C.
Full specifications
| Chamber volume | 500 l |
| Chamber volume | 500 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Heating mfr | 30 |
| Heat-up time3 mfr | 180 |
| Cool-down time3 from Tmax mfr | 210 |
| Inner dimensions (W × D × H) mfr | 750 × 1000 × 750 mm |
| Outer dimensions (W × D × H) mfr | 1410 × 1950 × 1960 mm |
| Weight | 1150 kg |
| Weight | 1150 kg |
| Max temperature | 850 °C |
| Max temperature | 850 °C |
Description
Construction and series positioning
- The NA 500/85 is a forced-convection chamber furnace with a 500 l working volume and inner dimensions of 750 × 1000 × 750 mm; outer dimensions are 1410 × 1950 × 1960 mm and unit weight is 1150 kg.
- It is the 500-litre, 850 °C member of the NA series; the sibling NA 500/45 shares the chamber size but has a lower maximum temperature, while the NA 250/85 offers the same 850 °C rating in a smaller 250-litre chamber. The NA 120/65 and NA 60/65 are smaller, lower-temperature variants.
- Heating is electric with a 3-phase connection; no voltage or power rating is stated in the verified facts, so the electrical design must be confirmed against the nameplate.
Thermal behaviour
- Maximum working temperature is 850 °C. The extra factory data list a heat-up time of 180 (unit not stated) and two cool-down times from Tmax of 900 and 210 (units not stated); because the units and the conditions for the two cool-down figures are not defined, these values are not usable as engineering specifications and are omitted from selection calculations.
- No digitized curve points are available, so the temperature uniformity and load-dependent behaviour cannot be quantified from the supplied facts; the controller documentation covers temperature uniformity per AMS2750F instrumentation types but does not print model-specific uniformity data.
Control and operation
- The controller documentation covers the Nabertherm standard controller series 500 and the MyNabertherm app, including process-data storage and recorder/controller options. No furnace-specific wiring, sensor type or control-loop details are printed in the supplied digests.
- The forced-convection principle implies a fan-driven atmosphere inside the chamber; the supplied facts do not state the fan drive, atmosphere compatibility or purge provisions, so protective-gas or reactive-atmosphere operation must be confirmed with the manufacturer.
Integration notes
- The unit is a floor-standing cabinet of roughly 1.4 × 2.0 × 2.0 m and 1150 kg; rigging, floor loading and clearance for door swing and service access must be planned from the outer dimensions.
- Because the electrical connection is 3-phase and no current or power value is given, the supply, protection and cable sizing cannot be derived from this card and must come from the nameplate or the manufacturer's connection data.
Integration & Operating Notes
The verified facts state only that the furnace is 3-phase; no voltage, current or connected load is given. The supply, protective device and cable cross-section must therefore be sized from the unit nameplate or the manufacturer's connection diagram, not from this card, and an incorrect supply voltage risks damage to the heating and control circuits.
The maximum temperature is 850 °C; operating above it risks heater and insulation damage. The supplied facts do not define a maximum load mass or a permitted atmosphere, so charge weight, fixture material and any protective-gas or fume extraction arrangement must be agreed with the manufacturer before processing unknown loads.
Selection & Integration Q&A
Choose the NA 500/85 when you need the 500 l chamber and processes up to 850 °C. The NA 500/45 gives the same 500 l volume at a lower maximum temperature, and the NA 250/85 gives the same 850 °C rating in a smaller 250 l chamber; pick the sibling that matches your load size and temperature together.
The verified facts state only a 3-phase connection; no voltage, current or connected load is given. Size the supply, protective device and cable from the unit nameplate or the manufacturer's connection diagram, and confirm the site voltage before ordering.
The verified facts list no accessories, cables, recorder or controller options as included. The controller documentation mentions recorder/controller options and the MyNabertherm app, but the fitted controller and any interface cables must be confirmed on the order configuration; do not assume they are part of the base unit.