Nabertherm NA 60/85
Nabertherm NA 60/85 — Forced Convection Furnaces.
The NA 60/85 is a 60-litre forced-convection chamber furnace with a 350 × 500 × 350 mm chamber, electrically heated to a maximum 850 °C and connected to a 3-phase supply. Within the NA series it is the smallest 850 °C modification, distinguished from the 60-litre NA 60/65 by its higher temperature ceiling. It serves batch heat treatment where forced air circulation is required for temperature uniformity.
Nabertherm NA Series — Model Comparison & Selection
Full specifications
| Chamber volume | 60 l |
| Chamber volume | 60 l |
| Chamber volume | 60 l |
| Chamber volume | 60 l |
| Chamber volume | 60 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Heating mfr | 9 |
| Heat-up time3 mfr | 150 |
| Cool-down time3 from Tmax mfr | 90 |
| Inner dimensions (W × D × H) mfr | 350 × 500 × 350 mm |
| Outer dimensions (W × D × H) mfr | 930 × 1310 × 1435 mm |
| Weight | 315 kg |
| Weight | 315 kg |
| Weight | 315 kg |
| Weight | 315 kg |
| Weight | 315 kg |
| Max temperature | 850 °C |
| Max temperature | 850 °C |
| Max temperature | 850 °C |
| Max temperature | 850 °C |
| Max temperature | 850 °C |
Description
Construction and series positioning
- Chamber volume 60 l; inner dimensions 350 × 500 × 350 mm (W × D × H); outer dimensions 930 × 1310 × 1435 mm; unit weight 315 kg.
- Maximum working temperature 850 °C, the highest ceiling in the NA series alongside the NA 250/85; the sibling NA 60/65 is the same 60-litre size at a lower temperature class, and the NA 120/65, NA 250/85 and NA 500/45 cover larger volumes.
- Electrically heated with forced convection; the heating rating is given as 9 in the factory data without a stated unit, so it is not quoted here as a power figure.
Thermal behaviour
- Factory heat-up time to temperature is listed as 150 (unit not stated in the source).
- Two cool-down times from Tmax are listed, 900 and 120, without distinguishing conditions; because the two values cannot be attributed to a single defined case, neither is asserted as the model's cooling performance.
- No digitized curve points were supplied, so no load-dependent or media-dependent behaviour is claimed beyond the temperature ceiling.
Control and documentation
- The attached controller documentation covers the Nabertherm 500 series and MyNabertherm app, including process data storage and AMS2750F temperature-uniformity instrumentation types; it does not print furnace model sizes, so controller fitment for the NA 60/85 must be confirmed at order.
- The fiber-optics catalog section lists forced-convection chamber furnaces NAT/NA up to 900 °C, consistent with the 850 °C class of this model.
Integration & Operating Notes
The electrical connection is specified only as 3-phase. The factory heating figure of 9 carries no unit, so the connected load and breaker sizing cannot be derived from these facts and must be taken from the nameplate or order documents before the supply is designed.
The chamber is rated to a maximum of 850 °C. Operating above this ceiling is outside the model's qualified range and risks damage to the heating and insulation; process recipes must be written with this limit as the setpoint ceiling.
The controller documentation describes the 500 series and MyNabertherm app with process data storage and AMS2750F instrumentation types, but prints no furnace model codes. Specify the controller, recorder and uniformity class explicitly on the order rather than assuming a default.
Selection & Integration Q&A
Pick the NA 60/85 when the 60-litre chamber (350 × 500 × 350 mm) is sufficient and the process needs up to 850 °C; the NA 60/65 is the same size at a lower temperature class. Move to NA 120/65, NA 250/85 or NA 500/45 only when a larger chamber volume is required.
A 3-phase supply is required; the source gives no unit for the heating figure, so connected load must come from the nameplate. The controller (500 series or MyNabertherm) and any recorder or AMS2750F instrumentation are separate selections, as the controller document lists no furnace model codes.
The controller, process-data recording and AMS2750F temperature-uniformity instrumentation described in the controller documentation are options, not base items, and the document prints no model-specific fitment. Confirm controller, recorder and any load-handling accessories on the order; no certificates or application kits are listed for this model.