Nabertherm SAL 120/85
Nabertherm SAL 120/85 — Forced Convection Furnaces.
The SAL 120/85 is a forced-convection pit-type furnace with a 120-litre chamber (450 × 450 × 600 mm) and a maximum temperature of 850 °C, heated electrically via a 3-phase connection. Its 80 kg charging weight and 400 kg unit mass distinguish it from the larger SAL 250/85 sibling in the series. It is intended for uniform heat treatment of loads lowered into the top-opening chamber.
Nabertherm SAL Series — Model Comparison & Selection
| Model | Chamber volume, L | Weight, kg | Electrical connection | Max temperature, °C |
|---|---|---|---|---|
| SAL 120/85 Current | 120 | 400 | 3-phase | 850 |
| SAL 250/85 | 250 | 600 | 3-phase | 850 |
Full specifications
| Chamber volume | 120 l |
| Chamber volume | 120 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Heating mfr | 13 |
| Inner dimensions (W × D × H) mfr | 450 × 450 × 600 mm |
| Outer dimensions (W × D × H) mfr | 1300 × 1100 × 1450 mm |
| Weight | 400 kg |
| Weight | 400 kg |
| Max. charging weight mfr | 80 |
| Max temperature | 850 °C |
| Max temperature | 850 °C |
Description
Construction and series positioning
- Pit-type (top-loading) architecture with a 120 l working volume; inner dimensions 450 × 450 × 600 mm (W × D × H).
- Outer envelope 1300 × 1100 × 1450 mm and unit weight 400 kg; the furnace is a fixed installation, not a benchtop unit.
- Within the SAL series, this model sits below the SAL 250/85: choose the 120/85 when the charge fits the 450 × 450 × 600 mm chamber and stays within the 80 kg maximum charging weight; the 250/85 is the larger-chamber sibling.
Thermal behaviour and load limits
- Maximum operating temperature 850 °C; heating is electric with a 3-phase supply.
- The 80 kg maximum charging weight is the load limit for the charge; it is independent of the 400 kg unit mass.
- No digitized heating curves were supplied, so no heat-up rate or uniformity figure is stated here.
Control and operation
- The attached controller documentation covers the Nabertherm 500-series controllers and the MyNabertherm app, including process-data storage and AMS2750F instrumentation types; the specific controller fitted to this unit is not fixed by the supplied facts.
- No furnace-specific manual digest was provided, so installation, connection and operating sequences are not detailed beyond the electrical and load data above.
Integration & Operating Notes
The furnace is specified for a 3-phase electrical connection. The supply, protection and cable sizing must be engineered for the actual installed unit; no current or power rating is given in the supplied facts, so the nameplate must be consulted before sizing the feed.
The maximum charging weight is 80 kg. Exceeding it overloads the charge support and the furnace structure; the limit applies to the total load placed in the 450 × 450 × 600 mm chamber, not to the 400 kg unit mass.
The maximum temperature of 850 °C must not be exceeded in any program step. No overshoot allowance is stated in the supplied facts; setpoint and controller limits should be configured so the chamber cannot run above this value.
Selection & Integration Q&A
Pick the SAL 120/85 when the charge fits the 450 × 450 × 600 mm chamber and weighs no more than 80 kg. The SAL 250/85 is the larger-chamber sibling; move to it when the workload exceeds the 120 l volume or the 80 kg charging limit.
The furnace is a 3-phase unit, but the supplied facts give no current or power rating. Size the feed, breaker and cable from the unit nameplate and the installation manual; do not assume a standard 3-phase circuit is adequate without that data.
The supplied facts contain no maintenance schedule, service intervals, error codes or accessory list for this model. Controller options are covered only generically in the Prozesssteuerung digest; cables, recorders and consumables must be confirmed with the order documentation.