Nabertherm TC 80/14
Nabertherm TC 80/14 — Bale Out Furnaces Electrically Heated Or Gas Fired.
The TC 80/14 is a SiC-rod-heated bale-out furnace with a BU 200 crucible and 650 kg melt capacity, rated to 1450 °C. Its 94 kW nominal power supports a melting performance of 1802 kg (likely per 24 h, per foundry catalog convention). It is intended for holding and melting non-ferrous alloys for manual or transfer-ladle casting in foundries.
Full specifications
| Heating power | 48 watt |
| Nominal power | 94 kW |
| Crucible mfr | BU 200 |
| Capacityin kg mfr | 650 |
| Melting performance3in kg mfr | 1802 |
| Outer dimensions (W × D × H) mfr | 1360 × 1350 × 1080 mm |
| Weight | 1050 kg |
| Max temperature | 1450 °C |
Description
Construction and series positioning
- The TC 80/14 is a bale-out furnace from Nabertherm's TC line, heated by silicon carbide rods and fitted with a BU 200 crucible.
- The crucible holds 650 kg of melt; the furnace outer envelope is 1360 × 1350 × 1080 mm and the unit weighs 1050 kg.
- Within the TC series, this model is defined by the BU 200 crucible size and the 650 kg capacity; no sibling models are listed in the verified data, so no direct size comparison can be made.
Thermal behavior and limits
- Maximum furnace temperature is 1450 °C, which sets the ceiling for superheat and alloy selection.
- Nominal connected power is 94 kW; the separate 48 W figure is a heating-power entry that is not consistent with a 94 kW melting furnace and is not used here.
- Melting performance is stated as 1802 kg; the unit is not specified in the verified data, so it should be confirmed against the foundry catalog before sizing a melt schedule.
Control and operation
- The attached controller digest covers the Nabertherm 500-series controllers and MyNabertherm app, including process-data storage and AMS2750F instrumentation types; the furnace is not shipped with a fixed controller configuration in the verified data.
- No curve points, installation clearances, or connection diagrams are present in the verified documents for this model; those must come from the model-specific operating manual.
Integration & Operating Notes
The SiC rod elements and crucible are rated to a maximum of 1450 °C. Operating above this ceiling risks element degradation and crucible failure; the setpoint must be interlocked or procedure-limited to this value.
The nominal power of 94 kW requires a dedicated supply sized for the furnace's actual voltage and phase configuration, which is not stated in the verified data. The electrical design must be taken from the model-specific nameplate and manual, not from the catalog overview.
The furnace is supplied with a BU 200 crucible and a stated capacity of 650 kg. Charging above the crucible's rated volume or weight, or using a non-matching crucible, changes the thermal profile and can damage the crucible or elements.
The controller digest describes 500-series controllers and MyNabertherm app functions, including process-data storage and AMS2750F instrumentation types, but does not fix a controller for this model. Specify the controller, thermocouples, and any recorder as separate line items.
SiC rod heating elements increase in resistance with age, so the furnace's power delivery changes over time. Plan for element resistance checks and replacement as a consumable item; the verified data gives no interval, so the model manual must define it.
Selection & Integration Q&A
Choose the TC 80/14 when the melt batch is built around a BU 200 crucible and about 650 kg of capacity at up to 1450 °C. No sibling TC models are listed in the verified data, so compare crucible size and capacity against the full TC range before ordering.
The furnace has a 94 kW nominal power rating, but the verified data does not state voltage or phase. Size the supply and protection from the model nameplate, and specify a 500-series controller or equivalent plus thermocouples separately, since the controller is not fixed in the verified data.
SiC rod elements are consumable and age with use; the verified data gives no replacement interval, so the model manual must define it. Controllers, recorders, thermocouples, and the BU 200 crucible's spare units are separate items, not part of the base furnace delivery.